Combined FIM-PHI-Based Wearable Biosensor

Focused impedance method (FIM) is a simple non-invasive way of diagnosing epidermal tissue health by subsequent measurements of localized impedance using a set of tetra-polar orthogonal electrodes. The concept is further advanced to an increased number of electrodes with repeated FIM cells that combinedly form a pigeon hole image (PHI) and used to diagnose a range of physiological conditions and disorders. In this work, a wearable imaging device has been demonstrated by combining the attributes of FIM-based pigeon hole imaging and utilised them for detecting unusual body mass within a biological system. The device uses a total of twenty-five Cu electrodes uniformly distributed over a spatial area <inline-formula> <tex-math notation="LaTeX">${A} = 16$ </tex-math></inline-formula> cm<sup>2</sup> which combinedly form the 16 elements of a <inline-formula> <tex-math notation="LaTeX">$4\times 4$ </tex-math></inline-formula> PHI matrix. The PHI device is capable to produce a 2D crude image of bio-impedance with a pixel resolution of 1 cm and visualise an unusual body mass underneath the testing surface at depth, <inline-formula> <tex-math notation="LaTeX">${d}_{p} \sim 0.3$ </tex-math></inline-formula> to 2.0 cm. The ubiquitous functionality of the device has been demonstrated by integrating into a custom made flexible fabric as wearable wrist band that measures the PHI image and recognizes three common gesture positions using a well-known artificial neural network classifier. The wearable device can be an emerging telemedicine solution for rapid screening of a range of abnormal physiological phenomenon at patient’s home or in a regional hospital with resource limited settings.

[1]  Amay J Bandodkar,et al.  Non-invasive wearable electrochemical sensors: a review. , 2014, Trends in biotechnology.

[2]  Nae-Eung Lee,et al.  Recent progress, challenges, and prospects of fully integrated mobile and wearable point-of-care testing systems for self-testing. , 2020, Chemical Society reviews.

[3]  Rushdi Zahid Rusho,et al.  Reconstruction algorithm for Pigeon Hole Imaging (PHI) , 2017, 2017 3rd International Conference on Electrical Information and Communication Technology (EICT).

[4]  M. Karal,et al.  A New Four-Electrode Focused Impedance Measurement (FIM) System for Physiological Study , 2008, Annals of Biomedical Engineering.

[5]  Camilo Silva,et al.  Clinical usefulness of abdominal bioimpedance (ViScan) in the determination of visceral fat and its application in the diagnosis and management of obesity and its comorbidities. , 2017, Clinical nutrition.

[6]  L Tian,et al.  Wearable sensors: modalities, challenges, and prospects. , 2018, Lab on a chip.

[7]  S. Demura,et al.  Percentage of total body fat as estimated by three automatic bioelectrical impedance analyzers. , 2004, Journal of physiological anthropology and applied human science.

[8]  L. Mathew,et al.  Increasing trend of wearables and multimodal interface for human activity monitoring: A review. , 2017, Biosensors & bioelectronics.

[9]  Aydogan Ozcan,et al.  Wearable and Implantable Sensors for Biomedical Applications. , 2018, Annual review of analytical chemistry.

[10]  R Beck,et al.  Continuous non-invasive measurement of stroke volume and cardiac index in infants and children: comparison of Impedance Cardiography NICaS® vs CardioQ® method. , 2018, La Clinica terapeutica.

[11]  S. Rudnev,et al.  Bioelectric Impedance Analysis , 2010, Definitions.

[12]  Paolo Dario,et al.  Smartphone-Based Food Diagnostic Technologies: A Review , 2017, Sensors.

[14]  S. Grimnes,et al.  The concept of transfer impedance in bioimpedance measurements , 2009 .

[15]  W. Russ Algar,et al.  Toward point-of-care diagnostics with consumer electronic devices: the expanding role of nanoparticles , 2015 .

[16]  S. Kain,et al.  Growth of wildtype and mutant E. coli strains in minimal media for optimal production of nucleic acids for preparing labeled nucleotides , 2010, Applied Microbiology and Biotechnology.

[17]  L. Ward Bioelectrical impedance analysis for body composition assessment: reflections on accuracy, clinical utility, and standardisation , 2018, European Journal of Clinical Nutrition.

[18]  Katharina Gaus,et al.  Real-Time Bioimpedance Sensing of Antifibrotic Drug Action in Primary Human Cells. , 2017, ACS sensors.

[19]  K. S. RABBANI,et al.  Focused Impedance Measurement (FIM): A New Technique with Improved Zone Localization , 1999, Annals of the New York Academy of Sciences.

[20]  Claude Nahmias,et al.  Radiation Risk to Children From Computed Tomography , 2008, Pediatrics.

[21]  T. Malý,et al.  Bioimpedance for Analysis of Body Composition in Sports , 2018 .

[22]  Matthew Tabinor,et al.  Bioimpedance-defined overhydration predicts survival in end stage kidney failure (ESKF): systematic review and subgroup meta-analysis , 2018, Scientific Reports.

[23]  R. Hendrick,et al.  Radiation doses and cancer risks from breast imaging studies. , 2010, Radiology.

[24]  J. O. Høgetveit,et al.  Comparison of four different FIM configurations—a simulation study , 2014, Physiological measurement.

[25]  Antoni Ivorra,et al.  A portable bioimpedance measurement system based on Red Pitaya for monitoring and detecting abnormalities in the gastrointestinal tract , 2016, 2016 IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES).

[26]  Q. Khan,et al.  Reducing Breast Cancer-Related Lymphedema (BCRL) Through Prospective Surveillance Monitoring Using Bioimpedance Spectroscopy (BIS) and Patient Directed Self-Interventions , 2018, Annals of Surgical Oncology.