Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography.

Intravascular ultrasound, a new technique for real-time two-dimensional visualization of arteries and veins, delineates vessel wall morphology and measures luminal dimensions. This imaging method has been validated with in vitro systems and in peripheral vessels, but there are few in vivo coronary artery studies. Twenty cardiac transplant recipients with no angiographic coronary artery disease were scanned with a 30-MHz intravascular ultrasound catheter from the left main coronary ostium to the mid-left anterior descending coronary artery. Simultaneous angiographic measurements were performed at 76 sites. Ultrasound end-diastolic diameters in two perpendicular axes were 3.8 +/- 0.9 and 3.9 +/- 0.6 mm, respectively, and mean diameter derived from an area determined by planimetry was 3.9 +/- 0.9 mm. Angiographic coronary artery diameters measured with a computer-assisted edge detection system perpendicular to the long axis of the vessel and to the long axis of the catheter were 3.4 +/- 0.8 and 3.6 +/- 0.8 mm, respectively. Luminal diameters measured with the two imaging systems correlated closely, with an r value of 0.86 when ultrasound was compared with the angiographic diameter measured perpendicular to the vessel and 0.88 when compared with the angiographic diameter measured perpendicular to the imaging catheter. Eighty-three percent of the ultrasound-measured diameters were above the line of identity when compared with the simultaneous angiographic measurement. The more the imaging catheter deviated from the long axis of the vessel, the greater was the discrepancy between the ultrasound and angiographic measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  A. Parisi,et al.  Reproducibility of echocardiography. A study evaluating the variability of serial echocardiographic measurements. , 1981, Chest.

[2]  T. Bashore,et al.  Intravascular ultrasonography versus digital subtraction angiography: a human in vivo comparison of vessel size and morphology. , 1990, Journal of the American College of Cardiology.

[3]  S. M. Collins,et al.  Visual estimates of percent diameter coronary stenosis: "a battered gold standard". , 1988, Journal of the American College of Cardiology.

[4]  N G Pandian,et al.  Ultrasound angioscopy: real-time, two-dimensional, intraluminal ultrasound imaging of blood vessels. , 1988, The American journal of cardiology.

[5]  M A Konstam,et al.  Intracardiac, intravascular, two-dimensional, high-frequency ultrasound imaging of pulmonary artery and its branches in humans and animals. , 1990, Circulation.

[6]  J. J. Gerbrands,et al.  Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. , 1985, Circulation.

[7]  S. Paulin,et al.  Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms. , 1983, Circulation.

[8]  Walter L. Henry,et al.  Intravascular Ultrasound Imaging of Human Coronary Arteries In Vivo: Analysis of Tissue Characterizations With Comparison to In Vitro Histological Specimens , 1991, Circulation.

[9]  N. Pandian,et al.  Intravascular and Intracardiac Ultrasound Imaging: Current Research and Future Directions , 1990, Echocardiography.

[10]  C. White,et al.  Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? , 1984, The New England journal of medicine.

[11]  E L Bolson,et al.  Quantitative computer techniques for analyzing coronary arteriograms. , 1986, Progress in cardiovascular diseases.

[12]  A J Tajik,et al.  Intravascular ultrasound imaging: in vitro validation and pathologic correlation. , 1990, Journal of the American College of Cardiology.

[13]  W. Roberts,et al.  Coronary artery imaging with intravascular high-frequency ultrasound. , 1990, Circulation.

[14]  Paul G. Yock,et al.  Intravascular ultrasound: development and clinical potential , 1988 .

[15]  C. Grines,et al.  Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography. , 1990, Circulation.

[16]  B. Waller,et al.  Coronary luminal shape and the arc of disease-free wall: morphologic observations and clinical relevance. , 1985, Journal of the American College of Cardiology.