Control strategies for smart prosthetic hand technology: An overview
暂无分享,去创建一个
Marco P. Schoen | Alba Perez | D.Subbaram Naidu | Cheng-Hung Chen | D. Naidu | M. Schoen | Cheng-Hung Chen | A. Perez
[1] C M Light,et al. Intelligent multifunction myoelectric control of hand prostheses , 2002, Journal of medical engineering & technology.
[2] Hong Liu,et al. Levenberg-Marquardt Based Neural Network Control for a Five-fingered Prosthetic Hand , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.
[3] P. Dario,et al. Control of multifunctional prosthetic hands by processing the electromyographic signal. , 2002, Critical reviews in biomedical engineering.
[4] J. Zajdlik. The Preliminary Design and Motion Control of a Five-fingered Prosthetic Hand , 2006, 2006 International Conference on Intelligent Engineering Systems.
[5] Silvestro Micera,et al. On the development of a novel adaptive prosthetic hand with compliant joints: experimental platform and EMG control , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.
[6] G.S. Dhillon,et al. Direct neural sensory feedback and control of a prosthetic arm , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[7] Maria Chiara Carrozza,et al. Biomechatronic Design and Control of an Anthropomorphic Artificial Hand for Prosthetic and Robotic Applications , 2007 .
[8] E D Sherman,et al. A Russian Bioelectric-Controlled Prosthesis. , 1965, Canadian Medical Association journal.
[9] Kenneth W. Horch,et al. Neuroprosthetics theory and practice , 2004 .
[10] Silvestro Micera,et al. The development of a novel prosthetic hand-ongoing research and preliminary results , 2002 .
[11] Neil M. White,et al. Control Strategies for a Multiple Degree of Freedom Prosthetic Hand , 2006 .
[12] Richard T. Johnson,et al. Development of the Utah Artificial Arm , 1982, IEEE Transactions on Biomedical Engineering.
[13] Alicia Casals,et al. Towards the definition of a functionality index for the quantitative evaluation of hand-prosthesis , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.
[14] Paolo Dario,et al. From the Human Hand to a Humanoid Hand: Biologically-Inspired Approach for the Development of RoboCasa Hand #1 , 2006 .
[15] Suguru Arimoto,et al. Control of an object with parallel surfaces by a pair of finger robots without object sensing , 2005, IEEE Transactions on Robotics.
[16] Seppo J. Ovaska,et al. Fusion of soft computing and hard computing in industrial applications: an overview , 2002, IEEE Trans. Syst. Man Cybern. Part C.
[17] Silvestro Micera,et al. A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems , 2005, Journal of the peripheral nervous system : JPNS.
[18] Sherman Ed. A RUSSIAN BIOELECTRIC-CONTROLLED PROSTHESIS: REPORT OF A RESEARCH TEAM FROM THE REHABILITATION INSTITUTE OF MONTREAL. , 1964 .
[19] A. Kargov,et al. Progress in the development of a multifunctional hand prosthesis , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[20] J C K Lai,et al. Prosthetic devices: Challenges and implications of robotic implants and biological interfaces , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[21] B. Rohrer,et al. A learning and control approach based on the human neuromotor system , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..
[22] Richard F. Weir,et al. A two degree-of-freedom microprocessor based extended physiological proprioception (EPP) controller for upper limb prostheses , 2003 .
[23] L. E. Rodríguez-Cheu,et al. Sensing and control of a prosthetic hand with myoelectric feedback , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..
[24] R.F. Weir,et al. The Optimal Controller Delay for Myoelectric Prostheses , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[25] Just L. Herder,et al. Voluntary closing: A promising opening in hand prosthetics , 2003 .
[26] Toshio Tsuji,et al. Bio-mimetic impedance control of an EMG-controlled prosthetic hand , 2000, Proceedings. 2000 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2000) (Cat. No.00CH37113).
[27] Sungchul Kang,et al. Development of Anthropomorphic Robot Hand with Tactile Sensor : SKKU Hand II , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.
[28] Peter J. Kyberd,et al. Advances in the control of prosthetic arms , 2003 .
[29] Paolo Dario,et al. Experimental analysis of an innovative prosthetic hand with proprioceptive sensors , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).
[30] O. von Stryk,et al. Design and Control Mechanisms for a 3 DOF Bionic Manipulator , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..
[31] K. Kilgore,et al. An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller. , 2002, The Journal of hand surgery.
[32] Dudley S Childress,et al. The effects of static friction and backlash on extended physiological proprioception control of a powered prosthesis. , 2005, Journal of rehabilitation research and development.
[33] R.Fff. Weir,et al. A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[34] José Luis Pons Rovira,et al. The MANUS-HAND Dextrous Robotics Upper Limb Prosthesis: Mechanical and Manipulation Aspects , 2004, Auton. Robots.
[35] K. Horch,et al. Towards a Neuroprosthetic Arm , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..
[36] Paolo Dario,et al. Design, fabrication and preliminary results of a novel anthropomorphic hand for humanoid robotics: RCH-1 , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).
[37] R. Dillmann,et al. Development of an anthropomorphic hand for a mobile assistive robot , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..
[38] John M. Miguelez,et al. Evolution of microprocessor based control systems in upper extremity prosthetics , 2003 .
[39] Patrick Grosch,et al. Software and Hardware Architecture , 2004 .
[40] Katsunari Shibata,et al. Prosthetic hand control based on torque estimation from EMG signals , 2000, Proceedings. 2000 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2000) (Cat. No.00CH37113).
[41] P.R. Troyk,et al. Technical Details of the Implantable Myoelectric Sensor (IMES) System for Multifunction Prosthesis Control , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.
[42] Bruno Siciliano,et al. Parallel force/position control of a novel biomechatronic hand prosthesis , 2003, Proceedings 2003 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM 2003).
[43] Fakhreddine O. Karray,et al. Soft Computing and Intelligent Systems Design, Theory, Tools and Applications , 2006, IEEE Transactions on Neural Networks.
[44] Hua Wang,et al. Dexterous Underwater Robot Hand: HEU Hand II , 2006, 2006 International Conference on Mechatronics and Automation.
[45] A. Kargov,et al. A comparison of the grip force distribution in natural hands and in prosthetic hands , 2004, Disability and rehabilitation.
[46] Godfrey Cm. A Russian Bioelectric-Controlled Prosthesis , 1965 .
[47] D. Naidu,et al. Optimal Control Systems , 2018 .
[48] Krishna Shenoy. Toward Neural Control of Prosthetic Devices , 2007 .