Design and Validation of a New PPG Module to Acquire High-Quality Physiological Signals for High-Accuracy Biomedical Sensing

A new photoplethysmography (PPG) module is designed, optimized, and fabricated in this study to obtain quality PPG signal for high-accuracy bio-sensing. The module contains four light emitting diodes (LEDs) in wavelengths of 530, 660, 850, and 940 nm and a photo-diode (PD). The distances between LEDs and PD are optimized for quality PPG signals via maximizing the ratios of pulsatile (ac) to non-pulsatile (dc) components in PPG waveforms. The optimization is carried out based on an establishment of a complete optical model that simulates well optics under the user's skin based on Beer–Lambert law. In results, the optimal LED/PD distances that lead to maximal ac/dc ratios of PPGs for different wavelengths are derived. With the optimal LEDs/PD distances in hand, a new PPG module is designed and fabricated subsequently, and further installed in a hand-held blood pressure (BP) sensing device for performance validation. Based on experimental results, for the PPG module, an ac/dc ratio of 8.02% is achieved by the proposed PPG module as opposed to 6.74% and 6.90% by two other commercial modules. As for sensing BP based on reflective pules transient time, the error is controlled well with the mean difference (MD) and standard deviation (SD) as −1.16 ± 5.38 (MD±SD) and −0.53 ± 1.92 mmHg, respectively, for systolic blood pressure and diastolic blood pressure. The resulted accuracy successfully categories the developed PPG sensor among the bests by Association for the Advancement of Medical Instrumentation and British Hypertension Society.

[1]  Nasser H. Kashou,et al.  New Window on Optical Brain Imaging; Medical Development, Simulations and Applications , 2012 .

[2]  D. Korteweg Ueber die Fortpflanzungsgeschwindigkeit des Schalles in elastischen Rhren , 1878 .

[3]  Robert Splinter,et al.  An Introduction to Biomedical Optics (Optics and Optoelectronics) , 2006 .

[4]  Panayiotis A. Kyriacou,et al.  Beer-lambert law along non-linear mean light pathways for the rational analysis of Photoplethysmography , 2010 .

[5]  Sijung Hu,et al.  A Multi-Channel Opto-Electronic Sensor to Accurately Monitor Heart Rate against Motion Artefact during Exercise , 2015, Sensors.

[7]  Tse-Yi Tu,et al.  Optimizing a new blood pressure sensor for maximum performance based on finite element model , 2014, IEEE SENSORS 2014 Proceedings.

[8]  S. Anderson,et al.  Blood pressure lowering for prevention of cardiovascular disease and death: a systematic review and meta-analysis , 2016, The Lancet.

[9]  E. O’Brien,et al.  The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. , 1990, Journal of hypertension.

[10]  Pratik Adhikari,et al.  Assessment of multi-wavelength pulse photometry for non-invasive dose estimation of circulating drugs and nanoparticles , 2016, SPIE BiOS.

[11]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .

[12]  D. Ku BLOOD FLOW IN ARTERIES , 1997 .

[13]  Richard Su,et al.  Optical clearing of skin enhanced with hyaluronic acid for increased contrast of optoacoustic imaging , 2016, Journal of biomedical optics.

[14]  Daniel McDuff,et al.  Remote Detection of Photoplethysmographic Systolic and Diastolic Peaks Using a Digital Camera , 2014, IEEE Transactions on Biomedical Engineering.

[15]  Mohanasankar Sivaprakasam,et al.  Arterial Blood Pressure Estimation From Local Pulse Wave Velocity Using Dual-Element Photoplethysmograph Probe , 2018, IEEE Transactions on Instrumentation and Measurement.

[17]  Yung-Hua Kao,et al.  Towards maximizing the sensing accuracy of an cuffless, optical blood pressure sensor using a high-order front-end filter , 2018 .

[18]  Lai-Man Po,et al.  Motion-Resistant Remote Imaging Photoplethysmography Based on the Optical Properties of Skin , 2015, IEEE Transactions on Circuits and Systems for Video Technology.

[19]  Nikos Stergiopulos,et al.  Pulse Wave Propagation in the Arterial Tree , 2011 .

[20]  M F O'Rourke,et al.  Vascular impedance in studies of arterial and cardiac function. , 1982, Physiological reviews.

[21]  H. Asada,et al.  Utility of the Photoplethysmogram in Circulatory Monitoring , 2008, Anesthesiology.

[22]  R. Wilson,et al.  Direct effects of smooth muscle relaxation and contraction on in vivo human brachial artery elastic properties. , 1995, Circulation research.

[23]  H.J.C.M. Sterenborg,et al.  Skin optics , 1989, IEEE Transactions on Biomedical Engineering.

[24]  Se Dong Min,et al.  Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study , 2017, BioMedical Engineering OnLine.

[25]  T. Meydan,et al.  Method for continuous nondisturbing monitoring of blood pressure by magnetoelastic skin curvature sensor and ECG , 2006, IEEE Sensors Journal.

[26]  Tse-Yi Tu,et al.  A new non-invasive cuff-less blood pressure sensor , 2013, 2013 IEEE SENSORS.

[27]  A. Kamshilin,et al.  Origin of Photoplethysmographic Waveform at Green Light , 2017 .

[28]  D. Lloyd‐Jones,et al.  Global Risk Assessment to Guide Blood Pressure Management in Cardiovascular Disease Prevention , 2017, Hypertension.

[29]  Tse-Yi Tu,et al.  Optimizing a new cuffless blood pressure sensor via a solid–fluid-electric finite element model with consideration of varied mis-positionings , 2016 .

[30]  A. Hill,et al.  The Velocity of the Pulse Wave in Man , 1922 .

[31]  T. Chakravarty,et al.  Bio-optical modeling of human skin to eliminate the skin structure variability in blood pressure measurement , 2016, 2016 2nd International Conference on Advances in Electrical, Electronics, Information, Communication and Bio-Informatics (AEEICB).

[32]  Takehiro Yamakoshi,et al.  Advanced Volume-Compensation Method for Indirect Finger Arterial Pressure Determination: Comparison with Brachial Sphygmomanometry , 2017, IEEE Transactions on Biomedical Engineering.

[33]  V. V. Tuchin Light scattering study of tissues , 1997 .

[34]  Yuan-Ting Zhang,et al.  Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio , 2016, IEEE Transactions on Biomedical Engineering.