Fault current limiters: a case study of protection and operational continuity for FPSOs

The Floating Production Storage Offloading offshore (FPSO) has been employed in the oil and gas exploration at the Brazilian pre-salt fields. Due to the increasing production capacity of process plants and consequently its power demands, FPSO power systems are experiencing higher fault current levels, which can present peak values of almost 200 kA in the medium voltage circuit. One solution to keep fault currents within safe values for the new electrical installations is to split the main switchgear busbar in two parts interconnecting them with a pyrotechnic device (PD). However, this typical fault current limiter (FCL) imposes operational restrictions to the FPSO; when the PD is triggered, the production of barrels is severely reduced. This work proposes two alternative FCLs to mitigate this problem: a Pyrotechnic Device (PD) associated with a parallel Air-Core Reactor (ACR) and a resistive Superconducting Fault Current Limiter (r-SFCL). As described in this manuscript, both alternatives allow full operation of the FPSO even after its actuation. The simulation model used to reproduce the transient behavior of two FCLs and the power system of typical FPSO was developed in the software Alternative Transients Program. The results show that the alternatives can limit the fault current below the main switchgear supportability limit, improving the reliability of FPSO’s production.

[1]  Luis M. Castro,et al.  Impact of Resistive Superconducting Fault Current Limiter and Distributed Generation on Fault Location in Distribution Networks , 2020 .

[2]  Hiroyuki Ohsaki,et al.  High Temperature Superconductor-Based Technologies as Enabler for Efficient and Resilient Energy Systems , 2019, IEEE Transactions on Applied Superconductivity.

[3]  P. Angays,et al.  Electrical installation on FPSO's — basic rules , 2009, 2009 Conference Record PCIC Europe.

[4]  E. Thibaut,et al.  All-Electrical FPSO Scheme With Variable-Speed Drive Systems , 2013, IEEE Transactions on Industry Applications.

[5]  Hazlie Mokhlis,et al.  Fault location and detection techniques in power distribution systems with distributed generation: A review , 2017 .

[6]  Antonio Morandi,et al.  State of the art of superconducting fault current limiters and their application to the electric power system , 2013 .

[7]  P. J. Costa Branco,et al.  Proposal for an RMS thermoelectric model for a resistive-type superconducting fault current limiter (SFCL) , 2010 .

[8]  W. H. Kersting,et al.  Short circuit analysis of IEEE test feeders , 2012, PES T&D 2012.

[9]  Raymond Catlett,et al.  MV system design: A paradigm shift , 2010, 2010 Record of Conference Papers Industry Applications Society 57th Annual Petroleum and Chemical Industry Conference (PCIC).

[10]  J. C. Das Limitations of current limiting protectors for expansion of electrical distribution systems , 1996, Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference.

[11]  R. C. Dugan,et al.  Matching the IEEE Test Feeder short circuit results , 2012, PES T&D 2012.

[12]  Marcio Zamboti Fortes,et al.  Application of resistive superconducting fault current limiters in offshore oil production platforms , 2017 .

[13]  Sagar S. Patil,et al.  Development of fault current limiters: A review , 2017, 2017 International Conference on Data Management, Analytics and Innovation (ICDMAI).

[14]  Antonio Colmenar-Santos,et al.  Performance analysis of a Superconducting Fault Current Limiter in a power distribution substation , 2016 .

[15]  Mahdi Zolfaghari,et al.  A survey on fault current limiters: Development and technical aspects , 2020 .

[16]  Frederick D. Painter,et al.  Root-Cause Analysis of Simultaneous Faults on an Offshore FPSO Vessel , 2014, IEEE Transactions on Industry Applications.

[17]  A. Abramovitz,et al.  Survey of Solid-State Fault Current Limiters , 2012, IEEE Transactions on Power Electronics.

[18]  Baris Kucukaydin,et al.  A new approach to limit fault current with series–parallel resonance strategy , 2020 .

[19]  Terence Hazel,et al.  Operation of power systems incorporating fault current limiting devices , 2015, 2015 Petroleum and Chemical Industry Conference Europe (PCIC Europe).

[20]  Mohsen Niasati,et al.  On the advance of SFCL: a comprehensive review , 2019, IET Generation, Transmission & Distribution.

[21]  Rutuja Jadhav,et al.  A Comprehensive Review on Fault Current Limiter for Power Network , 2019, 2019 International Conference on Recent Advances in Energy-efficient Computing and Communication (ICRAECC).

[22]  Dan Li,et al.  Energy based fuse modeling and simulation , 2013, 2013 IEEE Electric Ship Technologies Symposium (ESTS).

[23]  W Goldacker,et al.  ENSYSTROB—Resistive Fault Current Limiter Based on Coated Conductors for Medium Voltage Application , 2011, IEEE Transactions on Applied Superconductivity.

[24]  Terence Hazel,et al.  Ensuring switchgear integrity in high power installations , 2014, 2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC).

[26]  Antoine Rauzy,et al.  Production availability analysis of Floating Production Storage and Offloading (FPSO) systems , 2018 .

[27]  J. S. Scaffer Triggered current limiters for closing bus ties, bypassing reactors and improving power quality , 2000, 2000 Rural Electric Power Conference. Papers Presented at the 44th Annual Conference (Cat. No.00CH37071).