Extension of the compensated distortion method to the critical heat flux modelling in rectangular inclined channel
暂无分享,去创建一个
Parameters of critical heat flux modelling in inclined rectangular channels for high-pressure convective two-phase flows have been derived using the compensated distortion method of Ahmad [Int. J. Heat Mass Transfer 16 (1973) 641]. Freon R12 was used as the modelling fluid. A specific expression for the modelling parameter has been obtained by introducing a new dimensionless parameter that accounts for the effect of inclination on critical heat flux. This parameter is built by balancing the inertial force acting on a particle against the viscous effect corrected by a transverse term of gravity. In the same time, a dimensionless correlation of critical heat flux is proposed, which describes available data with an r.m.s. error of 13.1%.
[1] S. Y. Ahmad. Fluid to fluid modeling of critical heat flux: A compensated distortion model , 1973 .
[2] P. G. Barnett. THE SCALING OF FORCED CONVECTION BOILING HEAT TRANSFER , 1963 .
[3] M. Merilo. Fluid-to-fluid modeling and correlation of flow boiling crisis in horizontal tubes , 1979 .
[4] E. Buckingham. On Physically Similar Systems; Illustrations of the Use of Dimensional Equations , 1914 .