Clinical applications of 3-dimensional printing in radiation therapy.

Three-dimensional (3D) printing is suitable for the fabrication of complex radiotherapy bolus. Although investigated from dosimetric and feasibility standpoints, there are few reports to date of its use for actual patient treatment. This study illustrates the versatile applications of 3D printing in clinical radiation oncology through a selection of patient cases, namely, to create bolus for photon and modulated electron radiotherapy (MERT), as well as applicators for surface high-dose rate (HDR) brachytherapy. Photon boluses were 3D-printed to treat a recurrent squamous cell carcinoma (SCC) of the nasal septum and a basal cell carcinoma (BCC) of the posterior pinna. For a patient with a mycosis fungoides involving the upper face, a 3D-printed MERT bolus was used. To treat an SCC of the nose, a 3D-printed applicator for surface brachytherapy was made. The structures' fit to the anatomy and the radiotherapy treatment plans were assessed. Based on the treatment planning computed tomography (CT), the size of the largest air gap at the interface of the 3D-printed structure was 3 mm for the SCC of the nasal septum, 3 mm for the BCC of the pinna, 2 mm for the mycosis fungoides of the face, and 2 mm for the SCC of the nose. Acceptable treatment plans were obtained for the SCC of the nasal septum (95% isodose to 99.8% of planning target volume [PTV]), the BCC of the pinna (95% isodose to 97.7% of PTV), and the mycosis fungoides of the face (90% isodose to 92.5% of PTV). For the latter, compared with a plan with a uniform thickness bolus, the one featuring the MERT bolus achieved relative sparing of all the organs at risk (OARs) distal to the target volume, while maintaining similar target volume coverage. The surface brachytherapy plan for the SCC of the nose had adequate coverage (95% isodose to 95.6% of clinical target volume [CTV]), but a relatively high dose to the left eye, owing to its proximity to the tumor. 3D printing can be implemented effectively in the clinical setting to create highly conformal bolus for photon and MERT, as well as applicators for surface brachytherapy.

[1]  Martijn Kusters,et al.  Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  Ting Chen,et al.  Potential of 3D printing technologies for fabrication of electron bolus and proton compensators , 2015, Journal of applied clinical medical physics.

[3]  Shiqin Su,et al.  Design and production of 3D printed bolus for electron radiation therapy , 2014, Journal of applied clinical medical physics.

[4]  Z Xu,et al.  WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy. , 2014, Medical physics.

[5]  Scott Clarke,et al.  3D Printed Surface Applicators for High Dose Rate Brachytherapy , 2016 .

[6]  James Allan,et al.  PO-0941: 3D printed bolus for chestwall radiation therapy , 2016 .

[7]  C. Behrens,et al.  Dose build-up behind air cavities for Co-60, 4, 6 and 8 MV. Measurements and Monte Carlo simulations , 2006, Physics in medicine and biology.

[8]  Kyubo Kim,et al.  Evaluation of treatment plans using various treatment techniques for the radiotherapy of cutaneous Kaposi's sarcoma developed on the skin of feet , 2014, Journal of applied clinical medical physics.

[9]  S. Rana,et al.  Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes , 2013, Journal of medical physics.

[10]  Hun-Joo Shin,et al.  A Customized Bolus Produced Using a 3-Dimensional Printer for Radiotherapy , 2014, PloS one.

[11]  M. Kong,et al.  An investigation of central axis depth dose distribution perturbation due to an air gap between patient and bolus for electron beams , 2007, Australasian Physics & Engineering Sciences in Medicine.

[12]  D. Thrall,et al.  Effect of wetness level on the suitability of wet gauze as a substitute for Superflab as a bolus material for use with 6 mv photons. , 2009, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[13]  M. W. Johnson,et al.  Surface dose perturbation due to air gap between patient and bolus for electron beams. , 1993, Medical physics.

[14]  C. Yu,et al.  A systematic evaluation of air cavity dose perturbation in megavoltage x-ray beams. , 2000, Medical physics.

[15]  J. W. Park,et al.  Three-dimensional customized bolus for intensity-modulated radiotherapy in a patient with Kimura's disease involving the auricle. , 2016, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.