Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb.

Intramedullary nailing is probably the best method of treating long bone fractures in the lower limb. The operation is guided by fluoroscopy, for guide-wire insertion, fracture reduction and distal locking. No study so far has measured the scatter radiation to the patient's gonads during intramedullary, particularly femoral, nailing. The purpose here was to estimate the radiation hazard to the patients' gonads and surgeons' hands during intramedullary nailing for lower limb fractures. From April 1994 to June 1998, 184 consecutive patients had 224 nailings for lower limb fractures. Twenty-eight patients had Marchetti-Vincenzi nails and the rest had Russell-Taylor nails. There were 45 males and 40 females who had femoral nailing and 71 males and 28 females who had tibial nailing. The mean (range) age for femoral nailing was 56 (17-95.5) years and the mean age for tibia nailing was 44 (16.5-87.5) years. The average time of radiation when done by consultants was half that of middle-grade surgeons. The mean tibial nailing radiation time for the consultant was 0.56 min and for the middle-grade 1.28 min. The mean femoral nailing radiation time for the consultant was 0.52 min and for the middle-grade 1.61 min (P<0.05). The mean tibial and femoral nailing time were less for Marchetti nailing (P<0.05). Regular protection of the gonads of these patients is mandatory. This study shows that the radiation exposure for Marchetti-Vincenzi nailing is significantly less than for Russell-Taylor nailing. The overall radiation to patient gonads and surgeon hands was within acceptable limits.

[1]  B. Browner,et al.  Radiation exposure to the surgeon during closed interlocking intramedullary nailing. , 1987, The Journal of bone and joint surgery. American volume.

[2]  Merriam Gr,et al.  A clinical study of radiation cataracts and the relationship to dose. , 1957 .

[3]  S. Skjeldal,et al.  Interlocking medullary nails — Radiation doses in distal targeting , 2004, Archives of orthopaedic and traumatic surgery.

[4]  J. Kereiakes,et al.  Ionizing irradiation and the induction of clinically significant disease in the human thyroid gland. , 1977, The American journal of medicine.

[5]  R. Harrison Central-axis depth-dose data for diagnostic radiology. , 1981, Physics in medicine and biology.

[6]  K. D. De Smet,et al.  Closed intramedullary tibial nailing using the Marchetti-Vicenzi nail. , 2000, Injury.

[7]  M. Davis,et al.  Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures. , 1983, The Journal of bone and joint surgery. American volume.

[8]  E J van der Merwe,et al.  Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures. , 1992, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde.

[9]  A A Giachino,et al.  Irradiation of the surgeon during pinning of femoral fractures. , 1980, The Journal of bone and joint surgery. British volume.

[10]  Lo Nn,et al.  Radiation dosage from use of the image intensifier in orthopaedic surgery. , 1996 .

[11]  J. Hollingdale,et al.  Complications following the use of the Marchetti flexible intramedullary nail. , 1996, Injury.

[12]  P M Rommens,et al.  Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. , 1998, Injury.

[13]  T D Bunker,et al.  Radiation dosage during AO locking femoral nailing. , 1988, Injury.

[14]  S Stenzler,et al.  Exposure of the orthopaedic surgeon to radiation. , 1993, The Journal of bone and joint surgery. American volume.

[15]  J. P. Kelley,et al.  Scattered radiation from a tissue-equivalent phantom for x rays from 50 to 300 kVp. , 1972, Radiology.