Nanocalorimeters for biomolecular analysis and cell metabolism monitoring.

Nanocalorimeters, or microfabricated calorimeters, provide a promising way to characterize the thermal process of biological processes, such as biomolecule interactions and cellular metabolic activities. They enabled miniaturized heat measurement onto a chip device with potential benefits including low sample consumption, low cost, portability, and high throughput. Over the past few decades, researchers have tried to improve nanocalorimeters' performance, in terms of sensitivity, accuracy, and detection resolution, by exploring different sensing methods, thermal insulation techniques, and liquid handling methods. The enhanced devices resulted in new applications in recent years, and here we have summarized the performance parameters and applications based on categories. Finally, we have listed the current technical difficulties in nanocalorimeter research and hope for future solutions to overcome them.

[1]  T. Pawson,et al.  T Cell Activation-Induced CrkII Binding to the Zap70 Protein Tyrosine Kinase Is Mediated by Lck-Dependent Phosphorylation of Zap70 Tyrosine 3151 , 2005, The Journal of Immunology.

[2]  A. W. van Herwaarden,et al.  Chip calorimeter for thermal characterization of bio-chemical solutions , 2011 .

[3]  Janet E. Hiller,et al.  A systematic review of elastography, electrical impedance scanning, and digital infrared thermography for breast cancer screening and diagnosis , 2013, Breast Cancer Research and Treatment.

[4]  Yuan Jia,et al.  A microfabrication-based approach to quantitative isothermal titration calorimetry. , 2016, Biosensors & bioelectronics.

[5]  J. Ladbury,et al.  Water mediated protein‐DNA interactions: The relationship of thermodynamics to structural detail , 1996, Protein science : a publication of the Protein Society.

[6]  M. Kimura,et al.  Silicon-Based Micro Calorimeter With Single Thermocouple Structure for Thermal Characterization , 2019, IEEE Electron Device Letters.

[7]  C. Schick,et al.  Fast scanning calorimetry of lysozyme unfolding at scanning rates from 5 K/min to 500,000 K/min. , 2018, Biochimica et biophysica acta. General subjects.

[8]  M. Wootton,et al.  Application of Differential Scanning Calorimetry to Starch Gelatinization. III. Effect of Sucrose and Sodium Chloride , 1980 .

[9]  K. Kurabayashi,et al.  Room temperature picowatt-resolution calorimetry , 2011 .

[10]  L. Zuo,et al.  Review of MEMS differential scanning calorimetry for biomolecular study , 2017 .

[11]  H. Harms,et al.  Chip-calorimetry provides real time insights into the inactivation of biofilms by predatory bacteria , 2012, Biofouling.

[12]  R. Mahley,et al.  Apolipoprotein E4 Domain Interaction Mediates Detrimental Effects on Mitochondria and Is a Potential Therapeutic Target for Alzheimer Disease* , 2010, The Journal of Biological Chemistry.

[13]  V. Baier,et al.  Highly sensitive thermopile heat power sensor for micro-fluid calorimetry of biochemical processes , 2005 .

[14]  Takahito Ono,et al.  Highly sensitive thermometer using a vacuum-packed Si resonator in a microfluidic chip for the thermal measurement of single cells. , 2016, Lab on a chip.

[15]  Jacques Richard,et al.  Thermodynamics of small systems by nanocalorimetry: from physical to biological nano-objects , 2009 .

[16]  M. Kimura,et al.  Manufacturing and characterization of simple cantilever thermal biosensor with Si-Metal thermocouple structure for enzymatic reaction detection , 2018, Thermochimica Acta.

[17]  L. Zuo,et al.  A power compensated differential scanning calorimeter for protein stability characterization , 2018 .

[18]  Liwei Lin,et al.  Quantum dot nano thermometers reveal heterogeneous local thermogenesis in living cells. , 2011, ACS nano.

[19]  L. Zuo,et al.  Micro-differential scanning calorimeter for liquid biological samples. , 2016, The Review of scientific instruments.

[20]  E. Freire,et al.  Direct measurement of protein binding energetics by isothermal titration calorimetry. , 2001, Current opinion in structural biology.

[21]  L. Zuo,et al.  Atomic Layer-Deposited Titanium-Doped Vanadium Oxide Thin Films and Their Thermistor Applications , 2017, Journal of Electronic Materials.

[22]  A. Pfreundt,et al.  Fast differential scanning calorimetry of liquid samples with chips , 2015 .

[23]  G. Holdgate,et al.  Isothermal titration calorimetry in drug discovery. , 2001, Progress in medicinal chemistry.

[24]  Benyamin Davaji,et al.  A paper-based calorimetric microfluidics platform for bio-chemical sensing. , 2014, Biosensors & bioelectronics.

[25]  L. Zuo,et al.  Microfabrication of plastic-PDMS microfluidic devices using polyimide release layer and selective adhesive bonding , 2017 .

[26]  H. Harms,et al.  Chip calorimetry for the monitoring of whole cell biotransformation. , 2006, Journal of biotechnology.

[27]  E. Meyhofer,et al.  High resolution resistive thermometry for micro/nanoscale measurements. , 2012, The Review of scientific instruments.

[28]  Renkun Chen,et al.  Sub-picowatt/kelvin resistive thermometry for probing nanoscale thermal transport. , 2013, The Review of scientific instruments.

[29]  Ian W. Marison,et al.  Investigation of the potential of biocalorimetry as a process analytical technology (PAT) tool for monitoring and control of Crabtree-negative yeast cultures , 2011, Applied Microbiology and Biotechnology.

[30]  A. W. van Herwaarden,et al.  Overview of calorimeter chips for various applications , 2005 .

[31]  A. Minakov,et al.  High-speed dynamics of temperature distribution in ultrafast (up to 108 K/s) chip-nanocalorimeters, measured by infrared thermography of high resolution , 2019, Journal of Applied Physics.

[32]  Takahito Ono,et al.  Microfabricated Temperature-Sensing Devices Using a Microfluidic Chip for Biological Applications , 2018, Int. J. Autom. Technol..

[33]  Peter Kuhn,et al.  Enthalpy array analysis of enzymatic and binding reactions. , 2008, Analytical biochemistry.

[34]  V. Baier,et al.  Nano-calorimetry of small-sized biological samples , 2008 .

[35]  T. Thundat,et al.  Nanomechanical identification of liquid reagents in a microfluidic channel. , 2014, Lab on a chip.

[36]  S. Pastoreková,et al.  Measuring human blood serum with chip based fast liquid differential scanning calorimetry , 2016 .

[37]  A. Vercesi,et al.  Direct determination of anaerobe contributions to the energy metabolism of Trypanosoma cruzi by chip calorimetry , 2019, Analytical and Bioanalytical Chemistry.

[38]  P. Maurer,et al.  Nanometre-scale thermometry in a living cell , 2013, Nature.

[39]  Benyamin Davaji,et al.  A novel on-chip three-dimensional micromachined calorimeter with fully enclosed and suspended thin-film chamber for thermal characterization of liquid samples. , 2014, Biomicrofluidics.

[40]  Takahito Ono,et al.  Vanadium oxide thermal microsensor integrated in a microfluidic chip for detecting cholesterol and glucose concentrations , 2017 .

[41]  P. Sarro,et al.  Calorimeter chip calibration for thermal characterization of liquid samples , 2009 .

[42]  W. Hagen,et al.  Fast and accurate enzyme activity measurements using a chip-based microfluidic calorimeter. , 2018, Analytical biochemistry.

[43]  Fumihito Arai,et al.  Temperature changes in brown adipocytes detected with a bimaterial microcantilever. , 2014, Biophysical Journal.

[44]  M. Gijs,et al.  Dynamic microfluidic nanocalorimetry system for measuring Caenorhabditis elegans metabolic heat. , 2018, Lab on a chip.

[45]  T. Ono,et al.  Sensitive thermal microsensor with pn junction for heat measurement of a single cell , 2016 .

[46]  T. Ono,et al.  Nano and Microsensors for Mammalian Cell Studies , 2018, Micromachines.

[47]  Bin Wang,et al.  Demonstration of MEMS-based differential scanning calorimetry for determining thermodynamic properties of biomolecules , 2008 .

[48]  J. Wikswo,et al.  A microfabricated nanocalorimeter: design, characterization, and chemical calibration. , 2008, Analytical chemistry.

[49]  C. Demetzos Differential Scanning Calorimetry (DSC): A Tool to Study the Thermal Behavior of Lipid Bilayers and Liposomal Stability , 2008, Journal of liposome research.

[50]  T. Maskow,et al.  Chip calorimetry and its use for biochemical and cell biological investigations , 2008 .

[51]  F. Hänschke,et al.  Toward high-throughput chip calorimetry by use of segmented-flow technology , 2015 .

[52]  F. Baudenbacher,et al.  Nano-Calorimetry based point of care biosensor for metabolic disease management , 2017, Biomedical microdevices.

[53]  J. Leuthold,et al.  On-Chip Narrowband Thermal Emitter for Mid-IR Optical Gas Sensing , 2017 .

[54]  F. Yi,et al.  Nanoscale thermal analysis for nanomedicine by nanocalorimetry. , 2012, Wiley interdisciplinary reviews. Nanomedicine and nanobiotechnology.

[55]  Wonhee Lee,et al.  High-sensitivity microfluidic calorimeters for biological and chemical applications , 2009, Proceedings of the National Academy of Sciences.

[56]  J. Shin,et al.  High-sensitivity chip calorimeter platform for sub-nano watt thermal measurement , 2016 .

[57]  Takahito Ono,et al.  Enzyme immobilization in completely packaged freestanding SU-8 microfluidic channel by electro click chemistry for compact thermal biosensor , 2019, Process Biochemistry.

[58]  A. Feig,et al.  Heat capacity changes associated with nucleic acid folding , 2006, Biopolymers.

[59]  F. Hänschke,et al.  Thermopile chip based calorimeter for the study of aggregated biological samples in segmented flow , 2014 .

[60]  D. Laván,et al.  Characterization of a 10-MHz quadrant APD for measuring frequency oscillations and tip displacements of microcantilevers , 2012 .

[61]  F. Baudenbacher,et al.  Microfabricated calorimeters for thermometric enzyme linked immunosorbent assay in one-Nanoliter droplets , 2019, Biomedical Microdevices.

[62]  H. Olsson,et al.  Microcalorimetric investigation of cell metabolism in tumour cells from patients with non-Hodgkin lymphoma (NHL). , 2009, Scandinavian journal of haematology.

[63]  T. Thundat,et al.  Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers , 2016 .

[64]  Bruce C. Towe,et al.  Binding event measurement using a chip calorimeter coupled to magnetic beads , 2010 .

[65]  Yong-Jun Kim,et al.  A micromachined microcalorimeter with split-flow microchannel for biochemical sensing applications , 2008 .

[66]  Wenbin Cao,et al.  Polydimethylsiloxane microfluidic chip with integrated microheater and thermal sensor. , 2009, Biomicrofluidics.

[67]  Takahito Ono,et al.  Investigation of bimaterial cantilever beam for heat sensing in liquid , 2016 .

[68]  S. Tadigadapa,et al.  Calorimetric biosensors with integrated microfluidic channels. , 2004, Biosensors & bioelectronics.

[69]  B. M. Keller,et al.  Hyperthermia (heat shock)-induced protein denaturation in liver, muscle and lens tissue as determined by differential scanning calorimetry. , 1994, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[70]  I. Marison,et al.  Real-time monitoring and control of microbial bioprocesses with focus on the specific growth rate: current state and perspectives , 2012, Applied Microbiology and Biotechnology.

[71]  H. Harms,et al.  Chip-calorimetric monitoring of biofilm eradication with antibiotics provides mechanistic information. , 2013, International journal of medical microbiology : IJMM.

[72]  A. Pastore,et al.  A structural characterization of the interactions between titin Z-repeats and the alpha-actinin C-terminal domain. , 2001, Biochemistry.

[73]  F. Baudenbacher,et al.  Isothermal titration calorimetry in nanoliter droplets with subsecond time constants. , 2011, Analytical chemistry.

[74]  Renkun Chen,et al.  Sub-picowatt resolution calorimetry with niobium nitride thin-film thermometer. , 2014, The Review of scientific instruments.

[75]  N. Inada,et al.  A Cell-Permeable Fluorescent Polymeric Thermometer for Intracellular Temperature Mapping in Mammalian Cell Lines , 2015, PloS one.

[76]  A. Bachmann,et al.  Microcalorimetric assays for measuring cell growth and metabolic activity: methodology and applications. , 2015, Methods.

[77]  Takahito Ono,et al.  Pico calorimeter for detection of heat produced in an individual brown fat cell , 2012 .

[78]  C. Backhouse,et al.  Dynamic temperature measurement in microfluidic devices using thermochromic liquid crystals. , 2008, Lab on a chip.

[79]  John P. Wikswo,et al.  Heat conduction calorimeter for massively parallel high throughput measurements with picoliter sample volumes , 2004 .

[80]  P. Bataillard,et al.  Calorimetric sensing in bioanalytical chemistry : principles, applications and trends , 1993 .

[81]  J. Fiering,et al.  A continuous flow microfluidic calorimeter: 3-D numerical modeling with aqueous reactants. , 2015, Thermochimica acta.

[82]  J. Klein,et al.  Calorimetric analysis of the plasma proteome: identification of type 1 diabetes patients with early renal function decline. , 2013, Biochimica et biophysica acta.

[83]  L. Zuo,et al.  Thermodynamic analysis of a MEMS based differential scanning calorimeter model , 2019, Sensors and Actuators A: Physical.

[84]  F. Costa,et al.  A chip calorimetry-based method for the real-time investigation of metabolic activity changes in human erythrocytes caused by cell sickling , 2018, Journal of Thermal Analysis and Calorimetry.

[85]  Johannes Lerchner,et al.  Potentials and limitations of miniaturized calorimeters for bioprocess monitoring , 2011, Applied Microbiology and Biotechnology.

[86]  G. Kowalski,et al.  Microscale calorimetric device for determining reaction parameters , 2017 .

[87]  Nam-Trung Nguyen,et al.  Microcalorimeter: Design considerations, materials and examples , 2016 .

[88]  A. G. Bell,et al.  Enthalpy arrays. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[89]  Gerhard Klebe,et al.  Adding calorimetric data to decision making in lead discovery: a hot tip , 2010, Nature Reviews Drug Discovery.

[90]  K. Amemiya,et al.  Very low-noise large-area calorimeter based on bimetallic micromechanical transduction: toward sub-nanowatt resolution in air at room temperature , 2016 .

[91]  L. Zuo,et al.  A novel polyimide based micro heater with high temperature uniformity , 2017 .