Image quality of flat-panel cone beam CT

We present results on 3D image quality in terms of spatial resolution (MTF) and low contrast detectability, obtained on a flat dynamic X-ray detector (FD) based cone-beam CT (CB-CT) setup. Experiments have been performed on a high precision bench-top system with rotating object table, fixed X-ray tube and 176 x 176 mm2 active detector area (Trixell Pixium 4800). Several objects, including CT performance-, MTF- and pelvis phantoms, have been scanned under various conditions, including a high dose setup in order to explore the 3D performance limits. Under these optimal conditions, the system is capable of resolving less than 1% (~10 HU) contrast in a water background. Within a pelvis phantom, even inserts of muscle and fat equivalent are clearly distinguishable. This also holds for fast acquisitions of up to 40 fps. Focusing on the spatial resolution, we obtain an almost isotropic three-dimensional resolution of up to 30 lp/cm at 10% modulation.

[1]  E Klotz,et al.  Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. , 1999, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[2]  John Wong,et al.  Flat-panel cone-beam CT on a mobile isocentric C-arm for image-guided brachytherapy , 2002, SPIE Medical Imaging.

[3]  M. Grass,et al.  3D cone-beam CT reconstruction for circular trajectories. , 2000, Physics in medicine and biology.

[4]  Torsten Solf,et al.  Temporal artifacts in flat dynamic x-ray detectors , 2001, SPIE Medical Imaging.

[5]  Ralf Schmidt,et al.  Correction of amplifier nonlinearity, offset, gain, temporal artifacts, and defects for flat-panel digital imaging devices , 2002, SPIE Medical Imaging.

[6]  Jeffrey H. Siewerdsen,et al.  Volumetric cone-beam CT system based on a 41x41 cm2 flat-panel imager , 2001, SPIE Medical Imaging.

[7]  Falko Busse,et al.  Design and performance of a high-quality cardiac flat detector , 2002, SPIE Medical Imaging.

[8]  Ruola Ning,et al.  Selenium flat-panel detector-based volume tomographic angiography imaging: phantom studies , 1998, Medical Imaging.

[9]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[10]  Samit Kumar Basu,et al.  Design and image quality results from volumetric CT with a flat-panel imager , 2001, SPIE Medical Imaging.

[11]  T W Griffin,et al.  Cone-beam CT for radiotherapy applications. , 1995, Physics in medicine and biology.

[12]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[13]  Jeffrey H. Siewerdsen,et al.  Flat-panel cone-beam CT: a novel imaging technology for image-guided procedures , 2001, SPIE Medical Imaging.