Use of a Coronary Sinus Lead and Biventricular ICD to Correct a Sensing Abnormality in a Patient with Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy

Implantable cardioverter defibrillators (ICDs) are frequently offered to patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). Yet ICDs in these patients may be complicated by poor sensed amplitudes resulting from fatty and fibrous tissue replacement of right ventricular myocardium. We present the case of a patient with ARVD/C who had inappropriate detection of ventricular tachycardia with a single‐chamber ICD due to poor sensed right ventricular amplitudes. We discuss how the use of a bipolar coronary sinus lead and a biventricular ICD generator with a novel header configuration solved the problem.

[1]  H. Halperin,et al.  Implantable cardioverter-defibrillators in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy. , 2004, Journal of the American College of Cardiology.

[2]  R. Canby,et al.  Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. , 2003, JAMA.

[3]  R. Kerber,et al.  ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices , 2002 .

[4]  D. Delurgio,et al.  Cardiac resynchronization in chronic heart failure. , 2002, The New England journal of medicine.

[5]  H. Calkins,et al.  Lead Configuration for Defibrillator Implantation in a Patient with Congenital Heart Disease and a Mechanical Prosthetic Tricuspid Valve , 2001, Pacing and clinical electrophysiology : PACE.

[6]  L. Jordaens,et al.  Long term results of cardioverter-defibrillator implantation in patients with right ventricular dysplasia and malignant ventricular tachyarrhythmias , 2001, Heart.

[7]  M. Davies,et al.  Spectrum of clinicopathologic manifestations of arrhythmogenic right ventricular cardiomyopathy/dysplasia: a multicenter study. , 1997, Journal of the American College of Cardiology.

[8]  Paul J. Wang,et al.  Arrhythmogenic Right Ventricular Dysplasia: Clinical Results with Implantable Cardioverter Defibrillators , 1997, Journal of Interventional Cardiac Electrophysiology.

[9]  F. Marcus,et al.  Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy: A Review , 1995, Pacing and clinical electrophysiology : PACE.

[10]  H. Scheld,et al.  Implantable cardioverter defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy, long QT syndrome, or no structural heart disease. , 1994, American heart journal.

[11]  G. Thiene,et al.  Diagnosis of arrhythmogenic right ventricular dysplasia/cardiomyopathy. Task Force of the Working Group Myocardial and Pericardial Disease of the European Society of Cardiology and of the Scientific Council on Cardiomyopathies of the International Society and Federation of Cardiology. , 1994, British heart journal.

[12]  D. Corrado,et al.  Right ventricular cardiomyopathy and sudden death in young people. , 1988, The New England journal of medicine.