Effect of statistical uncertainties on Monte Carlo treatment planning

This paper reviews the effect of statistical uncertainties on radiotherapy treatment planning using Monte Carlo simulations. We discuss issues related to the statistical analysis of Monte Carlo dose calculations for realistic clinical beams using various variance reduction or time saving techniques. We discuss the effect of statistical uncertainties on dose prescription and monitor unit calculation for conventional treatment and intensity-modulated radiotherapy (IMRT) based on Monte Carlo simulations. We show the effect of statistical uncertainties on beamlet dose calculation and plan optimization for IMRT and other advanced treatment techniques such as modulated electron radiotherapy (MERT). We provide practical guidelines for the clinical implementation of Monte Carlo treatment planning and show realistic examples of Monte Carlo based IMRT and MERT plans.

[1]  T Pawlicki,et al.  Removing the effect of statistical uncertainty on dose-volume histograms from Monte Carlo dose calculations. , 2000, Physics in medicine and biology.

[2]  S B Jiang,et al.  Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system. , 2000, Physics in medicine and biology.

[3]  I. Kawrakow,et al.  History by history statistical estimators in the BEAM code system. , 2002, Medical physics.

[4]  T. Pawlicki,et al.  MCDOSE — A Monte Carlo Dose Calculation Tool for Radiation Therapy Treatment Planning , 2000 .

[5]  A E Nahum,et al.  Calculation of absorbed dose ratios using correlated Monte Carlo sampling. , 1993, Medical physics.

[6]  J Sempau,et al.  Towards the elimination of Monte Carlo statistical fluctuation from dose volume histograms for radiotherapy treatment planning. , 2000, Physics in medicine and biology.

[7]  P. Keall,et al.  Super-Monte Carlo: a 3-D electron beam dose calculation algorithm. , 1996, Medical physics.

[8]  David W. O. Rogers,et al.  Presta: The parameter reduced electron-step transport algorithm for electron monte carlo transport , 1986 .

[9]  S B Jiang,et al.  Monte Carlo modelling of electron beams from medical accelerators. , 1999, Physics in medicine and biology.

[10]  T Pawlicki,et al.  Monte Carlo simulation for MLC-based intensity-modulated radiotherapy. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[11]  H Hansson,et al.  Verification of a pencil beam based treatment planning system: output factors for open photon beams shaped with MLC or blocks. , 1999, Physics in medicine and biology.

[12]  L Chen,et al.  Monitor unit calculation for Monte Carlo treatment planning , 2004, Physics in medicine and biology.

[13]  Joseph O Deasy,et al.  Accelerating Monte Carlo simulations of radiation therapy dose distributions using wavelet threshold de-noising. , 2002, Medical physics.

[14]  T Pawlicki,et al.  Photon beam characterization and modelling for Monte Carlo treatment planning. , 2000, Physics in medicine and biology.

[15]  T. Mackie 6 – Applications of the Monte Carlo Method in Radiotherapy , 1990 .

[16]  I. Kawrakow The effect of Monte Carlo statistical uncertainties on the evaluation of dose distributions in radiation treatment planning. , 2004, Physics in medicine and biology.

[17]  P. Andreo Monte Carlo techniques in medical radiation physics. , 1991, Physics in medicine and biology.

[18]  Steve B. Jiang,et al.  Electron Beam Commissioning for Monte Carlo Dose Calculation , 2000 .

[19]  S B Jiang,et al.  Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning , 2000, Physics in medicine and biology.

[20]  J Yang,et al.  Optimization of combined electron and photon beams for breast cancer. , 2004, Physics in medicine and biology.

[21]  I Kawrakow,et al.  On the de-noising of Monte Carlo calculated dose distributions. , 2002, Physics in medicine and biology.

[22]  C. Ma,et al.  A particle track-repeating algorithm for proton beam dose calculation , 2005, Physics in medicine and biology.

[23]  C. Ma,et al.  Clinical implementation of a Monte Carlo treatment planning system. , 1999, Medical physics.

[24]  R. Mohan,et al.  The effect of dose calculation uncertainty on the evaluation of radiotherapy plans. , 2000, Medical physics.

[25]  Steve B Jiang,et al.  Modeling and Commissioning of Clinical Photon Beams for Monte Carlo Treatment Planning , 2000 .

[26]  A. Nahum,et al.  Monte Carlo dose calculations and radiobiological modelling: analysis of the effect of the statistical noise of the dose distribution on the probability of tumour control , 2000, Physics in medicine and biology.

[27]  C. Ma,et al.  Accurate characterization of Monte Carlo calculated electron beams for radiotherapy , 1997 .

[28]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[29]  J. Sempau,et al.  Monte Carlo simulation of electron beams from an accelerator head using PENELOPE , 2001, Physics in Medicine and Biology.

[30]  Frank Verhaegen,et al.  Monte Carlo modelling of external radiotherapy photon beams. , 2003, Physics in medicine and biology.

[31]  I. Kawrakow,et al.  3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC). , 1996, Medical physics.

[32]  C. Ma,et al.  A Monte Carlo dose calculation tool for radiotherapy treatment planning. , 2002, Physics in medicine and biology.

[33]  F. H. Attix,et al.  5 – Monte Carlo Techniques of Electron and Photon Transport for Radiation Dosimetry , 1990 .

[34]  Matthias Fippel,et al.  Smoothing Monte Carlo calculated dose distributions by iterative reduction of noise. , 2003, Physics in medicine and biology.