Investigation into the measured power-quality results and special output-limitation outcomes at Taichung Power Plant's onshore wind farm in Taiwan

This paper investigates and analyzes the measured power-quality results of an onshore wind farm with three wind-turbine generators connected to the power grid of Taiwan Power System. The three 2-MW wind permanent-magnet synchronous generators of the studied Taichung Power Plant's onshore wind farm are connected to the extra-high-voltage bus of 161 kV through a step-up three-winding distribution transformer of 161/23.9/11.9 kV, 60/30/30 MVA. The measured results were recorded from October 8th, 2015 to November 13th, 2015 for total 37 days. The recorded power-quality results include current harmonics, voltage flickers, and voltage variations. Special output-limitation outcomes of the studied wind farm were also recorded. According to the analyzed long-term measurement results, the power-quality indices such as system frequency, voltage variations, voltage flickers based on ΔV10, and total demand distortion of current at the point of common coupling can meet the grid code of Taiwan Power Company.

[1]  Li Wang,et al.  Integration of Wind Power and Wave Power Generation Systems Using a DC Microgrid , 2015, IEEE Transactions on Industry Applications.

[2]  Li Wang,et al.  Analysis of Measured Harmonic Currents and Voltages Contributed by a Commercial Wind Power System , 2007, 2007 IEEE Power Engineering Society General Meeting.

[3]  Li Wang,et al.  Simulations of a Commercial Wind Power Generation System with Four Wind-Turbine Induction Generators , 2007, 2007 IEEE Power Engineering Society General Meeting.

[4]  Li Wang,et al.  Integration of wind-power and wave-power generation systems using a DC micro grid , 2014, 2014 IEEE Industry Application Society Annual Meeting.

[5]  A. Floren,et al.  ' " ' " ' " . " ' " " " " " ' " ' " " " " " : ' " 1 , 2001 .

[6]  Li Wang,et al.  Analysis of measured flickers contributed by a commercial wind power generation system in Taiwan , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[7]  Li Wang,et al.  Analysis of measured power-quality results of Kuan-Yuan onshore wind farm in Taiwan , 2016, 2016 IEEE/IAS 52nd Industrial and Commercial Power Systems Technical Conference (I&CPS).

[8]  M.Manikanta Prasad,et al.  Stability Enhancement of Multi Machine system using a Unified Power Flow Controller , 2016 .

[9]  Sheng-Yen Lu,et al.  A preliminary study on total energy-density variations of a Buddhist temple in Taiwan through long-term field measurements of electric-field strength , 2014, 2014 IEEE Industry Application Society Annual Meeting.

[10]  Li Wang,et al.  Analysis of measured power-quality results of a PV system connected to Peng-Hu power system , 2014, 2014 IEEE Industry Application Society Annual Meeting.

[11]  Li Wang,et al.  Evaluation of measured power-quality results of a wind farm connected to Taiwan power system , 2014, 2014 IEEE Industry Application Society Annual Meeting.