Full-Scale Experiments of Fire Control and Suppression in Enclosed Car Parks: A Comparison Between Sprinkler and Water-Mist Systems

Recent efforts to investigate car-park fires and understand the related mechanisms have fostered the need for analyses of suppression performance against this type of fire scenario. This work aims at providing an insight into the ability of sprinklers and water-mist systems to control and extinguish a fire within an enclosed car park through a series of real-scale experiments. Three cars were employed in each test: the central one was ignited by a heptane pool fire and the adjacent ones served as targets. Two configurations were explored: in the first one, a nozzle was placed directly at the vertical axis of the ignition source, whereas the ignition source was located between the area coverage of four nozzles in the second one. The sprinkler system mainly served as a reference; two values of discharge density were evaluated for water mist at high operative pressure and a biodegradable surfactant was also tested against the most challenging configuration. A quantitative analysis of free-burn and discharge phases by temperature measurements was coupled with radiant heat-flux measurements and an assessment of post-fire damage. Sprinkler and water-mist systems were capable of containing the fire spread and thermally controlling the fire, thus preventing structural damage. The water mist’s ability to overpower the plume and reach the burning surfaces proved more effective than that of sprinklers, especially as no nozzles were located right above the ignition surface. The higher discharge density showed better capability of preventing re-ignition phenomena and suppression was attained in both the investigated configurations, which suggests that a certain amount of flux is also needed to achieve flame cooling. The additive had promising impact on suppression performance; however, more tests are required to specifically explore its ability to enhance thermal control.

[1]  H. P. Yule COMPUTATION OF EXPERIMENTAL RESULTS IN ACTIVATION ANALYSIS. , 1970 .

[2]  Michael Spearpoint,et al.  Fire load energy densities for risk-based design of car parking buildings , 2015 .

[3]  A. Marshall,et al.  ATOMIZATION AND DISPERSION MEASUREMENTS IN FIRE SPRINKLER SPRAYS , 2009 .

[4]  Bart Merci,et al.  Full-scale and reduced-scale tests on smoke movement in case of car park fire , 2013 .

[5]  Bart Merci,et al.  Smoke Control in Case of Fire in a Large Car Park: CFD Simulations of Full-scale Configurations , 2013 .

[6]  C. K. Chan,et al.  Numerical simulations on fire spread and smoke movement in an underground car park , 2007 .

[7]  Paolo Emilio Santangelo,et al.  Full-scale experiments of fire suppression in high-hazard storages: A temperature-based analysis of water-mist systems , 2012 .

[8]  M. Spearpoint,et al.  Distribution analysis of the fire severity characteristics of single passenger road vehicles using heat release rate data , 2013 .

[9]  K. F. Fong,et al.  Effect of Ventilation System on Smoke and Fire Spread in a Public Transport Interchange , 2008 .

[10]  A. D. Lemaire,et al.  Fire safety assessment of semi-open car parks based on validated CFD simulations , 2013 .

[11]  Gunnar Heskestad Scaling the interaction of water sprays and flames , 2002 .

[12]  Olavi Keski-Rahkonen,et al.  Characterization of the fire behaviour of a burning passenger car. part i: car fire experiments , 1994 .

[13]  Bart Merci,et al.  Smoke and heat control for fires in large car parks: Lessons learnt from research? , 2013 .

[14]  B. Pulvirenti,et al.  Fire suppression by water-mist sprays: Experimental and numerical analysis , 2010 .

[15]  Paolo Emilio Santangelo,et al.  Characterization of high-pressure water-mist sprays: Experimental analysis of droplet size and dispersion , 2010 .

[16]  Daniel M. Madrzykowski,et al.  Demonstration of biodegradable, environmentally safe, non-toxic fire suppression liquids , 1998 .

[17]  A. Y. Elghazouli,et al.  Robustness of multi-storey car parks under localised fire—Towards practical design recommendations , 2013 .

[18]  Alessandro Capra,et al.  Evaluation of flow direction methods against field observations of overland flow dispersion , 2012 .

[19]  Bart Merci,et al.  Smoke control in case of fire in a large car park: Full-scale experiments , 2013 .

[20]  L. Simões da Silva,et al.  DESIGN OF STEEL AND COMPOSITE OPEN CAR PARKS UNDER FIRE , 2013 .

[21]  Michael Spearpoint,et al.  Analysis of Vehicle Fire Statistics in New Zealand Parking Buildings , 2007 .

[22]  Bin Zhao,et al.  Structural behaviour of an open car park under real fire scenarios , 2004 .

[23]  Wan Ki Chow,et al.  Energy use for ventilation systems in underground car parks , 1998 .

[24]  Bart Merci Special issue fire safety journal on car park fire safety-preface , 2013 .

[25]  James R. Lawson,et al.  Measurement of droplet size in sprinkler sprays , 1988 .

[26]  Luc Taerwe,et al.  Thermo-mechanical analysis of an underground car park structure exposed to fire , 2013 .

[27]  David A. Nethercot,et al.  Robustness of multi-storey car parks under vehicle fire , 2012 .

[28]  Wan Ki Chow,et al.  FIELD STUDY ON THE INDOOR THERMAL ENVIRONMENT AND CARBON MONOXIDE LEVELS IN A LARGE UNDERGROUND CAR PARK , 1996 .

[29]  Bart Merci,et al.  CFD study of relation between ventilation velocity and smoke backlayering distance in large closed car parks , 2012 .

[30]  Michael Spearpoint,et al.  Measurements of the severity of fires involving private motor vehicles , 1995 .

[31]  David A. Nethercot,et al.  Simplified energy-based robustness assessment for steel-composite car parks under vehicle fire , 2013 .

[32]  Zhigang Liu,et al.  Examination of Performance of Water Mist Fire Suppression Systems under Ventilation Conditions , 2001 .

[33]  Wan Ki Chow,et al.  Survey on the indoor environment of enclosed car parks in Hong Kong , 1995 .

[34]  J. Viegas The use of impulse ventilation for smoke control in underground car parks , 2010 .

[35]  Wan Ki Chow SIMULATION OF CARBON MONOXIDE LEVEL IN ENCLOSED CAR PARKS USING AN AIR FLOW NETWORK PROGRAM , 1996 .

[36]  J Hill Car Park Designers' Handbook , 2005 .

[37]  Paolo E. Santangelo Experiments and modeling of discharge characteristics in water-mist sprays generated by pressure-swirl atomizers , 2012 .

[38]  P. Tartarini,et al.  Experimental Parametric Analysis of Water-Mist Sprays: An Investigation on Coalescence and Initial Dispersion , 2011 .

[39]  Eric Van den Bulck,et al.  Risk Analysis of LPG (liquefied petroleum gas) Vehicles in Enclosed Car Parks , 2013 .

[40]  Wan Ki Chow On safety systems for underground car parks , 1998 .

[41]  Arthur H. Lefebvre,et al.  Internal flow characteristics of simplex swirl atomizers , 1984 .

[42]  Ning Ren,et al.  Suppression effectiveness of water-mist sprays on accelerated wood-crib fires , 2014 .

[43]  G. Heskestad Extinction of gas and liquid pool fires with water sprays , 2003 .

[44]  Haukur Ingason,et al.  Measuring incident radiant heat flux using the plate thermometer , 2007 .