Effects of spiral confinement to the bond behavior of deformed reinforcement bars subjected to axial tension

Abstract When grouted pipe splice connections are employed, the structural performance of the connected precast concrete components is significantly influenced by the bond behavior between the main reinforcing bars and the surrounding grout. Owing to this important characteristic, the bond behavior, in particular the local bond-stress slip relationship and the bond strength, of the main steel reinforcement bars embedded in grout needs to be investigated accordingly. This paper presents the bond behavior of main deformed steel reinforcement bars confined by a grouted spiral connection. A total of 36 pullout specimens were tested under increasing axial tensile load to investigate the effects of spiral confinement to the connected main steel bars. Parameters covered in this study were spiral diameter and spiral pitch distance. The experimental results showed that the spiral configurations influence the bond performance due to the effect of confinement generated by the spiral diameter and pitch distance. As compared to spiral pitch distance, the spiral diameter provides more dominant confinement effect which subsequently increases the bond strength significantly.

[1]  D. Dias‐da‐Costa,et al.  Influence of anti-corrosive coatings on the bond of steel rebars to repair mortars , 2012 .

[2]  Kang Hai Tan,et al.  Size Effect in Large Prestressed Concrete Deep Beams , 1999 .

[3]  John E. Breen,et al.  ANCHORAGE BEHAVIOR OF HEADED REINFORCEMENT: LITERATURE REVIEW , 2002 .

[4]  Parviz Soroushian,et al.  Bond of Deformed Bars to Concrete: Effects of Confinement and Strength of Concrete , 1991 .

[5]  Robert L. Henry,et al.  Influence of Normal Pressure on Bond Strength , 1965 .

[6]  Maher K. Tadros,et al.  GROUT-FILLED PIPE SPLICES FOR PRECAST CONCRETE CONSTRUCTION , 1995 .

[7]  Ahmad Baharuddin Abdul Rahman,et al.  Effects of spiral diameter on the bond stress-slip relationship in grouted sleeve connector , 2015 .

[8]  George Morcous,et al.  Non-proprietary bar splice sleeve for precast concrete construction , 2015 .

[9]  H. Marzouk,et al.  Bond of high-strength concrete under monotonic pull-out loading , 2004 .

[10]  Yukimasa Goto,et al.  CRACKS FORMED IN CONCRETE AROUND DEFORMED TENSION BARS , 1971 .

[11]  Gaetano Manfredi,et al.  EXPERIMENTAL AND ANALYTICAL EVALUATION OF BOND PROPERTIES OF GFRP BARS , 2001 .

[12]  Ralejs Tepfers Overlap splices for ribbed bars for free use in a concrete structure , 1988 .

[13]  Mohd Zamin Jumaat,et al.  The relationship between interlocking mechanism and bond strength in elastic and inelastic segment of splice sleeve , 2014 .

[14]  Toshikatsu Ichinose,et al.  Analysis of bond splitting failure of deformed bars within structural concrete , 2008 .

[15]  Giovanni Plizzari,et al.  Towards a harmonised European bond test , 2003 .

[16]  Ralejs Tepfers,et al.  Cracking of concrete cover along anchored deformed reinforcing bars , 1979 .

[17]  Hsi Yoon Loh,et al.  Development of grouted splice sleeve and its performance under axial tension , 2008 .

[18]  A. Jafari,et al.  Bond of cement grouted reinforcing bars under constant radial pressure , 2005 .

[19]  Atorod Azizinamini,et al.  Tension development length of reinforcing bars embedded in high-strength concrete , 1995 .

[20]  Kent A. Harries,et al.  Experimental Study of Offset Mechanical Lap Splice Behavior , 2008 .

[21]  Huanzi Wang,et al.  An analytical study of bond strength associated with splitting of concrete cover , 2009 .

[22]  P. J. Robins,et al.  The influence of lateral pressure upon anchorage bond , 1984 .

[23]  Ahmad Baharuddin Abd. Rahman,et al.  Behaviour of grouted pipe splice under incremental tensile load , 2012 .

[24]  Deric J. Oehlers,et al.  Local and global bond characteristics of steel reinforcing bars , 2008 .

[25]  Ahmad Baharuddin Abd. Rahman,et al.  Analiza spiralne armature u injektiranim cjevastim spojevima , 2013 .

[26]  Abdul Karim Mirasa,et al.  Structural performance of splice connector for precast concrete structures , 2009 .

[27]  Parviz Soroushian,et al.  LOCAL BOND OF DEFORMED BARS WITH DIFFERENT DIAMETERS IN CONFINED CONCRETE , 1989 .

[28]  Maher K. Tadros,et al.  LAP SPLICES IN CONFINED CONCRETE , 1999 .