A cranial window imaging method for monitoring vascular growth around chronically implanted micro-ECoG devices

Implantable neural micro-electrode arrays have the potential to restore lost sensory or motor function to many different areas of the body. However, the invasiveness of these implants often results in scar tissue formation, which can have detrimental effects on recorded signal quality and longevity. Traditional histological techniques can be employed to study the tissue reaction to implanted micro-electrode arrays, but these techniques require removal of the brain from the skull, often causing damage to the meninges and cortical surface. This is especially unfavorable when studying the tissue response to electrode arrays such as the micro-electrocorticography (micro-ECoG) device, which sits on the surface of the cerebral cortex. In order to better understand the biological changes occurring around these types of devices, a cranial window implantation scheme has been developed, through which the tissue response can be studied in vivo over the entire implantation period. Rats were implanted with epidural micro-ECoG arrays, over which glass coverslips were placed and sealed to the skull, creating cranial windows. Vascular growth around the devices was monitored for one month after implantation. It was found that blood vessels grew through holes in the micro-ECoG substrate, spreading over the top of the device. Micro-hematomas were observed at varying time points after device implantation in every animal, and tissue growth between the micro-ECoG array and the window occurred in several cases. Use of the cranial window imaging technique with these devices enabled the observation of tissue changes that would normally go unnoticed with a standard device implantation scheme.

[1]  Tonio Ball,et al.  Evaluation of μECoG electrode arrays in the minipig: Experimental procedure and neurosurgical approach , 2011, Journal of Neuroscience Methods.

[2]  H. Dvorak,et al.  Expression of vascular permeability factor (vascular endothelial growth factor) by epidermal keratinocytes during wound healing , 1992, The Journal of experimental medicine.

[3]  Jorge Gonzalez-Martinez,et al.  Pathologic findings associated with invasive EEG monitoring for medically intractable epilepsy. , 2012, American journal of clinical pathology.

[4]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[5]  D. Heistad,et al.  Permeability of blood-brain barrier to various sized molecules. , 1985, The American journal of physiology.

[6]  D J Mooney,et al.  Bone Regeneration via a Mineral Substrate and Induced Angiogenesis , 2004, Journal of dental research.

[7]  David Kleinfeld,et al.  Chronic optical access through a polished and reinforced thinned skull. , 2010, Nature methods.

[8]  N. Nishimura,et al.  Real-Time Imaging of Perivascular Transport of Nanoparticles During Convection-Enhanced Delivery in the Rat Cortex , 2011, Annals of Biomedical Engineering.

[9]  Seong-Ho Choi,et al.  Spontaneous healing capacity of rabbit cranial defects of various sizes , 2010, Journal of periodontal & implant science.

[10]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[11]  U. Hofmann,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering a 32-site Neural Recording Probe Fabricated by Drie of Soi Substrates , 2022 .

[12]  Amiram Grinvald,et al.  Dural substitute for long-term imaging of cortical activity in behaving monkeys and its clinical implications , 2002, Journal of Neuroscience Methods.

[13]  D. Kleinfeld,et al.  Fluctuations and stimulus-induced changes in blood flow observed in individual capillaries in layers 2 through 4 of rat neocortex. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[14]  D. Kipke,et al.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. , 1999, Brain research. Brain research protocols.

[15]  Mark R. Bower,et al.  Microseizures and the spatiotemporal scales of human partial epilepsy. , 2010, Brain : a journal of neurology.

[16]  A. Villringer,et al.  Capillary perfusion of the rat brain cortex. An in vivo confocal microscopy study. , 1994, Circulation research.

[17]  Marie-Eve Tremblay,et al.  A Thin-skull Window Technique for Chronic Two-photon In vivo Imaging of Murine Microglia in Models of Neuroinflammation , 2010, Journal of visualized experiments : JoVE.

[18]  D J Weber,et al.  Human motor cortical activity recorded with Micro-ECoG electrodes, during individual finger movements , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  Daniel T. Montoro,et al.  Dura Mater Stimulates Human Adipose‐Derived Stromal Cells to Undergo Bone Formation in Mouse Calvarial Defects , 2011, Stem cells.

[20]  K. Svoboda,et al.  Long-term, high-resolution imaging in the mouse neocortex through a chronic cranial window , 2009, Nature Protocols.

[21]  M. Pepper,et al.  Hemangiomas - current therapeutic strategies. , 2011, The International journal of developmental biology.

[22]  K. Svoboda,et al.  Long-term in vivo imaging of experience-dependent synaptic plasticity in adult cortex , 2002, Nature.

[23]  David Beversdorf,et al.  Fabrication and testing of microelectrodes for small-field cortical surface recordings , 2006, Biomedical microdevices.

[24]  A. Tsimberidou,et al.  Lenalidomide in solid tumors , 2012, Cancer Chemotherapy and Pharmacology.

[25]  David J. Anderson,et al.  Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes , 2001 .

[26]  Dai Fukumura,et al.  In vivo imaging of tumors. , 2010, Cold Spring Harbor protocols.

[27]  Y. Oyama,et al.  Ectopic ossification in the cranial dura mater in dialysis patients with secondary hyperparathyroidism , 2009, NDT plus.

[28]  D. Szarowski,et al.  Brain responses to micro-machined silicon devices , 2003, Brain Research.

[29]  A. Schulze-Bonhage,et al.  First long term in vivo study on subdurally implanted Micro-ECoG electrodes, manufactured with a novel laser technology , 2011, Biomedical microdevices.

[30]  R. Jain,et al.  The candidate tumour suppressor protein ING4 regulates brain tumour growth and angiogenesis , 2004, Nature.

[31]  H. Dvorak,et al.  Vascular permeability factor/vascular endothelial growth factor, microvascular hyperpermeability, and angiogenesis. , 1995, The American journal of pathology.

[32]  R K Jain,et al.  Hypoxia and acidosis independently up-regulate vascular endothelial growth factor transcription in brain tumors in vivo. , 2001, Cancer research.

[33]  W. Gan,et al.  Choice of cranial window type for in vivo imaging affects dendritic spine turnover in the cortex , 2007, Nature Neuroscience.

[34]  Shayn M Peirce,et al.  FTY720 promotes local microvascular network formation and regeneration of cranial bone defects. , 2010, Tissue engineering. Part A.

[35]  Justin C. Williams,et al.  A Micro-Electrocorticography Platform and Deployment Strategies for Chronic BCI Applications , 2011, Clinical EEG and neuroscience.

[36]  Gerwin Schalk,et al.  A brain–computer interface using electrocorticographic signals in humans , 2004, Journal of neural engineering.

[37]  Ying Song,et al.  Direct labeling and visualization of blood vessels with lipophilic carbocyanine dye DiI , 2008, Nature Protocols.

[38]  Brian Litt,et al.  Flexible, Foldable, Actively Multiplexed, High-Density Electrode Array for Mapping Brain Activity in vivo , 2011, Nature Neuroscience.