Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS.
暂无分享,去创建一个
Leimin Fan | M. Rieser | Tawakol A El-Shourbagy | Raymond Naxing Xu | Matthew J Rieser | Leimin Fan | T. El-Shourbagy | R. Xu
[1] S. Unger,et al. A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma. , 2006, Rapid communications in mass spectrometry : RCM.
[2] T. Olah,et al. Development of an on-line extraction turbulent flow chromatography tandem mass spectrometry method for cassette analysis of Caco-2 cell based bi-directional assay samples. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[3] Kenneth R Wehmeyer,et al. Semi-automated liquid--liquid back-extraction in a 96-well format to decrease sample preparation time for the determination of dextromethorphan and dextrorphan in human plasma. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[4] Mohammed Jemal,et al. Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard. , 2003, Rapid communications in mass spectrometry : RCM.
[5] H. Niederländer,et al. High throughput therapeutic drug monitoring of clozapine and metabolites in serum by on-line coupling of solid phase extraction with liquid chromatography-mass spectrometry. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[6] B. Casetta,et al. Inclusion of MPA and in a rapid multi-drug LC-tandem mass spectrometric method for simultaneous determination of immunosuppressants. , 2006, Clinica chimica acta; international journal of clinical chemistry.
[7] O. Al-Dirbashi,et al. UPLC-MS/MS determination of doxazosine in human plasma , 2006, Analytical and bioanalytical chemistry.
[8] D. Musson,et al. Determination of M+4 stable isotope labeled cortisone and cortisol in human plasma by microElution solid-phase extraction and liquid chromatography/tandem mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.
[9] E. Skoglund,et al. Generic three-column parallel LC-MS/MS system for high-throughput in vitro screens. , 2004, Journal of chromatography. A.
[10] M. Jemal,et al. Increased productivity in quantitative bioanalysis using a monolithic column coupled with high-flow direct-injection liquid chromatography/tandem mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.
[11] K. Koch,et al. Increasing throughput of parallel on-line extraction liquid chromatography/electrospray ionization tandem mass spectrometry system for GLP quantitative bioanalysis in drug development. , 2004, Rapid communications in mass spectrometry : RCM.
[12] R. Fisk,et al. Performance of an ultra-low elution-volume 96-well plate: drug discovery and development applications. , 2003, Rapid communications in mass spectrometry : RCM.
[13] Shaolian Zhou,et al. Critical Review of Development, Validation, and Transfer for High Throughput Bioanalytical LC-MS/MS Methods , 2005 .
[14] Jamie J. Zhao,et al. Quantitative analysis of simvastatin and its beta-hydroxy acid in human plasma using automated liquid-liquid extraction based on 96-well plate format and liquid chromatography-tandem mass spectrometry. , 2004, Journal of pharmaceutical and biomedical analysis.
[15] X. Zang,et al. A novel on-line solid-phase extraction approach integrated with a monolithic column and tandem mass spectrometry for direct plasma analysis of multiple drugs and metabolites. , 2005, Rapid communications in mass spectrometry : RCM.
[16] G. Hopfgartner,et al. Determination of talinolol in human plasma using automated on-line solid phase extraction combined with atmospheric pressure chemical ionization tandem mass spectrometry. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[17] W. Weinmann,et al. Ion suppression effects in liquid chromatography-electrospray-ionisation transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[18] R L Foltz,et al. Ionization enhancement in atmospheric pressure chemical ionization and suppression in electrospray ionization between target drugs and stable-isotope-labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry. , 2003, Rapid communications in mass spectrometry : RCM.
[19] C. Chassaing,et al. A Parallel Micro Turbulent Flow Chromatography-Tandem Mass Spectrometry Method for the Analysis of a Pharmaceutical Compound in Plasma , 2005 .
[20] N. Asakawa,et al. On-line pretreatment using methylcellulose-immobilized cation-exchange restricted access media for direct liquid chromatography/mass spectrometric determination of basic drugs in plasma. , 2005, Rapid communications in mass spectrometry : RCM.
[21] N. Xu,et al. Automated 96-well liquid-liquid back extraction liquid chromatography-tandem mass spectrometry method for the determination of ABT-202 in human plasma. , 2004, Journal of pharmaceutical and biomedical analysis.
[22] Joachim Thiery,et al. Rapid simultaneous quantification of immunosuppressants in transplant patients by turbulent flow chromatography combined with tandem mass spectrometry. , 2004, Clinica chimica acta; international journal of clinical chemistry.
[23] R. Plumb,et al. High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.
[24] F. Tse,et al. HIGH-THROUGHPUT MASS SPECTROMETRIC ANALYSIS OF XENOBIOTICS IN BIOLOGICAL FLUIDS , 2002 .
[25] S. Laufer,et al. Quantitative determination of piritramide in human plasma and urine by off- and on-line solid-phase extraction liquid chromatography coupled to tandem mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.
[26] Y. L. Loukas,et al. Development and validation of a rapid 96-well format based liquid-liquid extraction and liquid chromatography-tandem mass spectrometry analysis method for ondansetron in human plasma. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[27] T. Ikegami,et al. Monolithic columns for high-efficiency HPLC separations. , 2004, Current opinion in chemical biology.
[28] David Q. Liu,et al. Use of online-dual-column extraction in conjunction with chiral liquid chromatography tandem mass spectrometry for determination of terbutaline enantiomers in human plasma. , 2002, Chirality.
[29] B. Matuszewski,et al. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. , 2003, Analytical chemistry.
[30] Q. Ji,et al. 96-Well liquid-liquid extraction liquid chromatography-tandem mass spectrometry method for the quantitative determination of ABT-578 in human blood samples. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[31] Yuan-qing Xia,et al. Automated online dual-column extraction coupled with teicoplanin stationary phase for simultaneous determination of (R)- and (S)-propranolol in rat plasma using liquid chromatography-tandem mass spectrometry. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[32] T. L. Lloyd,et al. High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma. , 2002, Rapid communications in mass spectrometry : RCM.
[33] Mike Larson,et al. High-throughput biological sample analysis using on-line turbulent flow extraction combined with monolithic column liquid chromatography/tandem mass spectrometry. , 2005, Rapid communications in mass spectrometry : RCM.
[34] Yuan-Qing Xia,et al. LC-MS Development strategies for quantitative bioanalysis. , 2006, Current drug metabolism.
[35] J. Schellens,et al. Switching from an analogous to a stable isotopically labeled internal standard for the LC-MS/MS quantitation of the novel anticancer drug Kahalalide F significantly improves assay performance. , 2004, Biomedical chromatography : BMC.
[36] K. Cabrera. Applications of silica-based monolithic HPLC columns. , 2004, Journal of separation science.
[37] Lili Dong,et al. Ultra performance liquid chromatography–tandem mass spectrometry for the determination of epirubicin in human plasma , 2005 .
[38] Jim X. Shen,et al. Orthogonal extraction/chromatography and UPLC, two powerful new techniques for bioanalytical quantitation of desloratadine and 3-hydroxydesloratadine at 25 pg/mL. , 2006, Journal of pharmaceutical and biomedical analysis.
[39] Walter A. Korfmacher,et al. Ultra-performance liquid chromatography/tandem mass spectrometric determination of testosterone and its metabolites in in vitro samples. , 2006, Rapid communications in mass spectrometry : RCM.
[40] Walter A. Korfmacher,et al. Increasing speed and throughput when using HPLC-MS/MS systems for drug metabolism and pharmacokinetic screening. , 2006, Current drug metabolism.
[41] Qin C Ji,et al. Method development and validation for zotarolimus concentration determination in stented swine arteries by liquid chromatography/tandem mass spectrometry detection. , 2006, Rapid communications in mass spectrometry : RCM.
[42] M. Churchwell,et al. Improving LC-MS sensitivity through increases in chromatographic performance: comparisons of UPLC-ES/MS/MS to HPLC-ES/MS/MS. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[43] J. Henion,et al. High-throughput selected reaction monitoring liquid chromatography-mass spectrometry determination of methylphenidate and its major metabolite, ritalinic acid, in rat plasma employing monolithic columns. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[44] G. Duncan,et al. Removal of metabolite interference during liquid chromatography/tandem mass spectrometry using high‐field asymmetric waveform ion mobility spectrometry , 2005 .
[45] J. Veuthey,et al. Column-Switching Procedures for the Fast Analysis of Drugs in Biologic Samples , 2004, Therapeutic drug monitoring.
[46] Serge Rudaz,et al. Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures. , 2004, Journal of chromatography. A.
[47] N. Koseki,et al. Simultaneous quantitative determination of cyclosporine A and its three main metabolites (AM1, AM4N and AM9) in human blood by liquid chromatography/mass spectrometry using a rapid sample processing method. , 2006, Rapid communications in mass spectrometry : RCM.
[48] Jim X. Shen,et al. Minimization of ion suppression in LC-MS/MS analysis through the application of strong cation exchange solid-phase extraction (SCX-SPE). , 2005, Journal of pharmaceutical and biomedical analysis.
[49] T. Olah,et al. Tandem mass spectrometry with online high-flow reversed-phase extraction and normal-phase chromatography on silica columns with aqueous-organic mobile phase for quantitation of polar compounds in biological fluids. , 2005, Rapid communications in mass spectrometry : RCM.
[50] E. Matsushima,et al. Improvement in precision of the liquid chromatographic-electrospray ionization tandem mass spectrometric analysis of 3'-C-ethynylcytidine in rat plasma. , 2001, Journal of chromatography. B, Biomedical sciences and applications.
[51] W. Naidong,et al. Analysis of omeprazole and 5-OH omeprazole in human plasma using hydrophilic interaction chromatography with tandem mass spectrometry (HILIC-MS/MS)--eliminating evaporation and reconstitution steps in 96-well liquid/liquid extraction. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[52] Sherry Wang,et al. Does a stable isotopically labeled internal standard always correct analyte response? A matrix effect study on a LC/MS/MS method for the determination of carvedilol enantiomers in human plasma. , 2007, Journal of pharmaceutical and biomedical analysis.
[53] E. Kwong,et al. Combining restricted access material (RAM) and turbulent flow for the rapid on-line extraction of the cyclooxygenase-2 inhibitor rofecoxib in plasma samples. , 2005, Journal of chromatography. A.
[54] Olga Kavetskaia,et al. Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma. , 2005, Journal of chromatography. A.
[55] S. Wren,et al. Use of ultra-performance liquid chromatography in pharmaceutical development. , 2006, Journal of chromatography. A.
[56] James L. Little,et al. Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[57] R. Vreeken,et al. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[58] X. Xu,et al. Quantitative determination of a novel dual PPAR α/γ agonist using on-line turbulent flow extraction with liquid chromatography-tandem mass spectrometry , 2005 .
[59] Klaus Resch,et al. Direct and fast determination of antiretroviral drugs by automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry in human plasma , 2006, Clinical chemistry and laboratory medicine.
[60] Y. Alnouti,et al. Method for internal standard introduction for quantitative analysis using on-line solid-phase extraction LC-MS/MS. , 2006, Analytical chemistry.
[61] W. Shou,et al. Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma. , 2003, Journal of pharmaceutical and biomedical analysis.
[62] J. Mazzeo,et al. Advancing LC Performance with Smaller Particles and Higher Pressure , 2005 .
[63] Perry G Wang,et al. Validation and application of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of lopinavir and ritonavir in human plasma using semi-automated 96-well liquid-liquid extraction. , 2006, Journal of chromatography. A.
[64] D. Fraier,et al. Ion-suppression effects in liquid chromatography-tandem mass spectrometry due to a formulation agent, a case study in drug discovery bioanalysis. , 2005, Journal of pharmaceutical and biomedical analysis.
[65] Bradley L Ackermann,et al. Recent advances in use of LC/MS/MS for quantitative high-throughput bioanalytical support of drug discovery. , 2002, Current topics in medicinal chemistry.
[66] Qin C Ji,et al. A high-throughput liquid chromatography/tandem mass spectrometry method for simultaneous quantification of a hydrophobic drug candidate and its hydrophilic metabolite in human urine with a fully automated liquid/liquid extraction. , 2006, Rapid communications in mass spectrometry : RCM.
[67] J. Purnell. Dynamics of chromatography, part I, principles and theory By J. Calvin Giddings. Pp. xii + 323, Edward Arnold, London. 1965. 90s , 1966 .
[68] Grace E Kim,et al. A monolithic-phase based on-line extraction approach for determination of pharmaceutical components in human plasma by HPLC-MS/MS and a comparison with liquid-liquid extraction. , 2006, Journal of pharmaceutical and biomedical analysis.
[69] B. Matuszewski. Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[70] E. Kwong,et al. A method for the direct analysis of drug compounds in plasma using a single restricted access material (RAM) column. , 2004, Journal of pharmaceutical and biomedical analysis.
[71] E. Woolf,et al. Determination of dextromethorphan and its metabolite dextrorphan in human urine using high performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry: a study of selectivity of a tandem mass spectrometric assay. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[72] S. Unger,et al. A 96-well single-pot liquid-liquid extraction, hydrophilic interaction liquid chromatography-mass spectrometry method for the determination of muraglitazar in human plasma. , 2006, Journal of pharmaceutical and biomedical analysis.
[73] J. Henion,et al. High-throughput liquid chromatography-tandem mass spectrometry determination of bupropion and its metabolites in human, mouse and rat plasma using a monolithic column. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[74] Ian R. Whittall,et al. A demonstration of the use of ultra-performance liquid chromatography-mass spectrometry [UPLC/MS] in the determination of amphetamine-type substances and ketamine for forensic and toxicological analysis. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[75] W. Naidong,et al. Bioanalytical liquid chromatography tandem mass spectrometry methods on underivatized silica columns with aqueous/organic mobile phases. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[76] Louis W. Chang,et al. Clinical-scale high-throughput analysis of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine by isotope-dilution liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction. , 2006, Clinical chemistry.
[77] Shu-Ying Chang,et al. Automated on-line SPE LC-MS/MS method to quantitate 6beta-hydroxycortisol and cortisol in human urine: use of the 6beta-hydroxycortisol to cortisol ratio as an indicator of CYP3A4 activity. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[78] H. Zeng,et al. Fast analysis using monolithic columns coupled with high-flow on-line extraction and electrospray mass spectrometric detection for the direct and simultaneous quantitation of multiple components in plasma. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[79] C. Mallet,et al. A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts. , 2004, Rapid communications in mass spectrometry : RCM.