CheapStat: An Open-Source, “Do-It-Yourself” Potentiostat for Analytical and Educational Applications

Although potentiostats are the foundation of modern electrochemical research, they have seen relatively little application in resource poor settings, such as undergraduate laboratory courses and the developing world. One reason for the low penetration of potentiostats is their cost, as even the least expensive commercially available laboratory potentiostats sell for more than one thousand dollars. An inexpensive electrochemical workstation could thus prove useful in educational labs, and increase access to electrochemistry-based analytical techniques for food, drug and environmental monitoring. With these motivations in mind, we describe here the CheapStat, an inexpensive (<$80), open-source (software and hardware), hand-held potentiostat that can be constructed by anyone who is proficient at assembling circuits. This device supports a number of potential waveforms necessary to perform cyclic, square wave, linear sweep and anodic stripping voltammetry. As we demonstrate, it is suitable for a wide range of applications ranging from food- and drug-quality testing to environmental monitoring, rapid DNA detection, and educational exercises. The device's schematics, parts lists, circuit board layout files, sample experiments, and detailed assembly instructions are available in the supporting information and are released under an open hardware license.

[1]  A. Bond,et al.  Inexpensive microprocessor controlled programmable function generators for use in electrochemistry , 1980 .

[2]  George M Whitesides,et al.  Egg beater as centrifuge: isolating human blood plasma from whole blood in resource-poor settings. , 2008, Lab on a chip.

[3]  Dmitrii E. Makarov,et al.  A mechanistic study of electron transfer from the distal termini of electrode-bound, single-stranded DNAs. , 2010, Journal of the American Chemical Society.

[4]  M. van Swaay XCVI. Practical potentiostat-coulometer for the student laboratory and for routine research use , 1978 .

[5]  Yassin A. Hassan,et al.  Rapid PCR Thermocycling using Microscale Thermal Convection , 2011, Journal of visualized experiments : JoVE.

[6]  Matthew D. Steinberg,et al.  A micropower amperometric potentiostat , 2004 .

[7]  Y. Matsui,et al.  Arsenic intake via water and food by a population living in an arsenic-affected area of Bangladesh. , 2007, The Science of the total environment.

[8]  Kevin W Plaxco,et al.  Linear, redox modified DNA probes as electrochemical DNA sensors. , 2007, Chemical communications.

[9]  Orawon Chailapakul,et al.  Electrochemical detection for paper-based microfluidics. , 2009, Analytical chemistry.

[10]  G. Whitesides,et al.  Understanding wax printing: a simple micropatterning process for paper-based microfluidics. , 2009, Analytical chemistry.

[11]  Michelle Khine,et al.  Better shrinkage than Shrinky-Dinks. , 2010, Lab on a chip.

[12]  G. Forsberg,et al.  Determination of arsenic by anodic stripping voltammetry and differential pulse anodic stripping voltammetry , 1975 .

[13]  Ryan J. White,et al.  Effects of probe length, probe geometry, and redox-tag placement on the performance of the electrochemical E-DNA sensor. , 2009, Analytical chemistry.

[14]  Ashwini Vittal Gopinath,et al.  An Inexpensive Field-Portable Programmable Potentiostat , 2005 .

[15]  Luke P. Lee,et al.  Shrinky-Dink microfluidics: 3D polystyrene chips. , 2008, Lab on a chip.

[16]  O. Brown Control of electrochemical experiments by an inexpensive personal microcomputer , 1982 .

[17]  Sungkil Hwang,et al.  CMOS VLSI Potentiostat for Portable Environmental Sensing Applications , 2010, IEEE Sensors Journal.

[18]  David E. King,et al.  Measuring Vitamin C Content of Commercial Orange Juice Using a Pencil Lead Electrode , 2010 .

[19]  Bradley A. Minch,et al.  Design of a CMOS Potentiostat Circuit for Electrochemical Detector Arrays , 2007, IEEE Transactions on Circuits and Systems I: Regular Papers.

[20]  J. Stock A simple low-current potentiostat coulometric analysis , 1968 .

[21]  Dafu Cui,et al.  Multi-channel electrochemical detection system based on LabVIEW , 2004, International Conference on Information Acquisition, 2004. Proceedings..

[22]  Luke P. Lee,et al.  Shrinky-Dink microfluidics: rapid generation of deep and rounded patterns. , 2008, Lab on a chip.

[23]  M. Kimura,et al.  An Integrated Potentiostat With an Electrochemical Cell Using Thin-Film Transistors , 2009, IEEE Transactions on Electron Devices.

[24]  Roya Maboudian,et al.  Silver dendrites from galvanic displacement on commercial aluminum foil as an effective SERS substrate. , 2010, Journal of the American Chemical Society.

[25]  George M Whitesides,et al.  Electrochemical sensing in paper-based microfluidic devices. , 2010, Lab on a chip.

[26]  J. Lubin,et al.  Inorganic arsenic in drinking water: an evolving public health concern. , 2007, Journal of the National Cancer Institute.

[27]  Cheng Wei T Yang,et al.  Using inexpensive Jell-O chips for hands-on microfluidics education. , 2010, Analytical chemistry.

[28]  Chun-Yueh Huang,et al.  A Portable Potentiostat with Molecularly Imprinted Polymeric Electrode for Dopamine Sensing , 2009, 2009 IEEE Circuits and Systems International Conference on Testing and Diagnosis.

[29]  S. W. Lee,et al.  Determination of total arsenic species by anodic stripping voltammetry , 1981 .

[30]  Victor M Ugaz,et al.  A pocket-sized convective PCR thermocycler. , 2007, Angewandte Chemie.

[31]  Kevin W Plaxco,et al.  Preparation of electrode-immobilized, redox-modified oligonucleotides for electrochemical DNA and aptamer-based sensing , 2007, Nature Protocols.

[32]  B. Vassos,et al.  Computer interfaceable potentiostat , 1978 .

[33]  George M Whitesides,et al.  Integration of paper-based microfluidic devices with commercial electrochemical readers. , 2010, Lab on a chip.

[34]  M. A. Valle,et al.  Easy-to-Make Ag/AgCl Reference Electrode , 2000 .

[35]  Audrey K. Ellerbee,et al.  Quantifying colorimetric assays in paper-based microfluidic devices by measuring the transmission of light through paper. , 2009, Analytical chemistry.

[36]  R. Prakash,et al.  Determination of total arsenic content in water by atomic absorption spectroscopy (AAS) using vapour generation assembly (VGA). , 2006, Chemosphere.

[37]  Kevin W. Plaxco,et al.  E-DNA sensors for convenient, label-free electrochemical detection of hybridization , 2008 .

[38]  C. L. Spencer,et al.  Inexpensive Raman Spectrometer for Undergraduate and Graduate Experiments and Research. , 2010 .

[39]  R. Kakerow,et al.  Low-power Single-chip CMOS Potentiostat , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[40]  Chunhai Fan,et al.  Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[41]  Victor M Ugaz,et al.  A buoyancy-driven compact thermocycler for rapid PCR. , 2007, Clinics in laboratory medicine.

[42]  W. Heineman,et al.  Cyclic voltammetry experiment , 1983 .

[43]  T. D. Hatchard,et al.  Design and Testing of a Low-Cost Multichannel Pseudopotentiostat for Quantitative Combinatorial Electrochemical Measurements on Large Electrode Arrays , 2003 .

[44]  George M Whitesides,et al.  Thin, lightweight, foldable thermochromic displays on paper. , 2009, Lab on a chip.

[45]  Wei W. Yu,et al.  Inkjet printed surface enhanced Raman spectroscopy array on cellulose paper. , 2010, Analytical chemistry.

[46]  William W. Goldsworthy,et al.  A DIGITAL POTENTIOSTAT , 1971 .

[47]  H. Ahsan,et al.  Cancer burden from arsenic in drinking water in Bangladesh. , 2004, American journal of public health.

[48]  D. Westneat,et al.  An inexpensive, easily constructed spectrophotometer , 1953 .