Correction terms for contacts to diffused resistors

Correction terms obtained from measurements on typical planar resistors are given and compared to values expected from two different mechanisms: inhomogeneous current flow around the contact or contact resistance between metal and diffusion layer. Good agreement between contact resistance model and experiment is shown.