The effect of changing excitation frequency on parallel conductance in different sized hearts.

OBJECTIVE An important component of the ventricular volume measured using the conductance catheter technique is due to parallel conductance (Vc), which results from the extension of the electric field beyond the ventricular blood pool. Parallel conductance volume is normally estimated using the saline dilution method (Vc(saline dilution)), in which the conductivity of blood in the ventricle is transiently increased by injection of hypertonic saline. A simpler alternative has been reported by Gawne et al. [12]. Vc(dual frequency) is estimated from the difference in total conductance measured at two exciting frequencies and the method is based on the assumption that parallel conductance is mainly capacitive and hence is negligible at low frequency. The objective of this study was to determine whether the dual frequency technique could be used to substitute the saline dilution method to estimate Vc in different sized hearts. METHODS The accuracy and linearity of a custom-built conductance catheter (CC) system was initially assessed in vitro. Subsequently, a CC and micromanometer were inserted into the left ventricle of seven 5 kg pigs (group 1) and six 50 kg pigs (group 2). Cardiac output was determined using thermodilution (group 1) and an ultrasonic flow probe (group 2) from which the slope coefficient (alpha) was determined. Steady state measurements and Vc estimated using saline dilution were performed at frequencies in the range of 5-40 kHz. All measurements were made at end-expiration. Finally, Vc was estimated from the change in end-systolic conductance between 5 kHz and 40 kHz using the dual frequency technique of Gawne et al. [12]. RESULTS There was no change in measured volume of a simple insulated cylindrical model when the stimulating frequency was varied from 5-40 kHz. Vc(saline dilution) varied significantly with frequency in group 1 (8.63 +/- 2.74 ml at 5 kHz; 11.51 +/- 2.65 ml at 40 kHz) (p = 0.01). Similar results were obtained in group 2 (69.43 +/- 27.76 ml at 5 kHz; 101.24 +/- 15.21 ml at 40 kHz) (p < 0.001). However, the data indicate that the resistive component of the parallel conductance is substantial (Vc at 0 Hz estimated as 8.01 ml in group 1 and 62.3 ml in group 2). There was an increase in alpha with frequency in both groups but this did not reach significance. The correspondence between Vc(dual frequency) and Vc(saline dilution) methods was poor (group 1 R2 = 0.69; group 2 R2 = 0.22). CONCLUSION At a lower excitation frequency of 5 kHz a smaller percentage of the electric current extends beyond the blood pool so parallel conductance is reduced. While parallel conductance is frequency dependent, it has a substantial resistive component. The dual frequency method is based on the assumption that parallel conductance is negligible at low frequencies and this is clearly not the case. The results of this study confirm that the dual frequency technique cannot be used to substitute the saline dilution technique.

[1]  A A Shoukas,et al.  Instantaneous Pressure‐Volume Relationship of the Canine Right Ventricle , 1979, Circulation research.

[2]  D. Kass,et al.  Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts. , 1985, Circulation.

[3]  H. Schwan,et al.  Specific Resistance of Body Tissues , 1956, Circulation research.

[4]  E. T. van der Velde,et al.  Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter. , 1981, Cardiovascular research.

[5]  N. Sperelakis,et al.  Electrical Impedance of Cardiac Muscle , 1961, Circulation research.

[6]  D. Burkhoff,et al.  Assessment of right ventricular contractile state with the conductance catheter technique in the pig. , 1995, Cardiovascular research.

[7]  G V Heller,et al.  Instantaneous measurement of left and right ventricular stroke volume and pressure-volume relationships with an impedance catheter. , 1984, Circulation.

[8]  O. Hess,et al.  Left ventricular volume determination in dogs: a comparison between conductance technique and angiocardiography. , 1988, European heart journal.

[9]  L. Benson,et al.  Measurement of right ventricular volume by conductance catheter in closed-chest pigs. , 1995, The American journal of physiology.

[10]  B Buis,et al.  Continuous measurement of left ventricular volume in animals and humans by conductance catheter. , 1984, Circulation.

[11]  S. Rush,et al.  Resistivity of Body Tissues at Low Frequencies , 1963, Circulation research.

[12]  W. Grossman,et al.  Assessment of left ventricular end-systolic pressure-volume relations with an impedance catheter and transient inferior vena cava occlusion: use of this system in the evaluation of the cardiotonic effects of dobutamine, milrinone, Posicor and epinephrine. , 1986, Journal of the American College of Cardiology.

[13]  D. Kass,et al.  Determination of left ventricular end-systolic pressure-volume relationships by the conductance (volume) catheter technique. , 1986, Circulation.

[14]  F. Duck Physical properties of tissue , 1990 .

[15]  W L Maughan,et al.  Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man. , 1988, Catheterization and cardiovascular diagnosis.

[16]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[17]  T J Gawne,et al.  Estimating left ventricular offset volume using dual-frequency conductance catheters. , 1987, Journal of applied physiology.

[18]  J. G. Webster,et al.  Impedance of Skeletal Muscle from 1 Hz to 1 MHz , 1984, IEEE Transactions on Biomedical Engineering.