Research on power measurement device of jamming bomb based on Infrared Radiation

In order to realize the non-connect measurement on the power and character of jamming bomb, we carried out the research on power measurement device of jamming bomb based on Infrared Radiation. First, the power and infrared radiant band of the jamming bomb was summarized and refined. Then, ensuring the feature and power of jamming bomb was characterized by the magnitude of Infrared Radiation. Afterwards, based on the theory of the above, a power measurement device of Infrared Radiation was simulated and developed. Including the selection of detector and the detector application design, analog signal processing and digital signal processing, using correlation measurement method to detect and calculate the power of device. Finally, the specific method and advantage of the device was introduced. The results of the experiment show that: the response time of the device is less than 3ms; the detection sensitivity is better than 3 x 108cm √HZ / W . The device successfully accomplished the accuracy measurement of Infrared Radiation between 1 to 20um wavelength with higher detection sensitivity and lower response time.