Stationary Charging Station Design for Sustainable Urban Rail Systems: A Case Study at Zhuzhou Electric Locomotive Co., China

In 2014, more than 43 cities in China were racing to construct their urban rail systems (including metro and light rail systems), recognizing that an urban rail system will be a good solution to the tough problems that they are faced with, including traffic congestion and PM2.5 air pollution. On 22 August 2012, the first electric double-layer capacitor (EDLC) energy storage-type rail vehicle in the world was unveiled at Zhuzhou Electric Locomotive Co., China. The EDLC rail system has been considered a promising sustainable urban rail system, which is expected to further improve the energy efficiency and to reduce environmental pollution. The first commercial EDLC tram produced by Zhuzhou Electric Locomotive Co. has been applied at Guangzhou Metro Corp. recently. From the view point of scientific research, the system design and energy management of EDLC rail systems have been extensively studied in the literature, while the stationary charging station design for the EDLC energy storage-type urban rail vehicles has been rarely reported. Thus, the aim of this paper is to report a stationary charging station that has been successfully applied in the EDLC rail system produced by Zhuzhou Electric Locomotive Co., China.

[1]  Flavio Ciccarelli,et al.  Stationary ultracapacitors storage device for improving energy saving and voltage profile of light transportation networks , 2012 .

[2]  CORNELIA AIDA BULUCEA,et al.  Experimental Characterization of Environmental Impacts from Underground Electric Metro in Braking Regime , 2007 .

[3]  武彦 福島 持続可能性(Sustainability)の要件 , 2006 .

[4]  Diego Iannuzzi,et al.  The Use of Energy Storage Systems for Supporting the Voltage Needs of Urban and Suburban Railway Contact Lines , 2013 .

[5]  Davide Lauria,et al.  Optimal design of stationary supercapacitors storage devices for light electrical transportation systems , 2011 .

[6]  Malin Song,et al.  Energy Consumption and Energy Efficiency of the Transportation Sector in Shanghai , 2014 .

[7]  Wei Da He,et al.  Research on the Evaluation of China’s Automotive Industry Security: Based on Gray Model , 2014 .

[8]  Xinbo Ruan,et al.  DC/DC Conversion Systems Consisting of Multiple Converter Modules: Stability, Control, and Experimental Verifications , 2009, IEEE Transactions on Power Electronics.

[9]  CORNELIA AIDA BULUCEA,et al.  Energy and Exergy Efficiencies in Urban Electric Transportation Systems , 2008 .

[10]  R Barrero,et al.  Stationary or onboard energy storage systems for energy consumption reduction in a metro network , 2010 .

[11]  J. B. Wang,et al.  Study of cable resistance and remote-sensing scheme in parallel DC/DC converter system via primary droop current-sharing control , 2012 .

[12]  P. Barrade,et al.  A supercapacitor-based energy storage substation for voltage compensation in weak transportation networks , 2004, IEEE Transactions on Power Delivery.

[13]  Haixiao Pan Pan Implementing Sustainable Urban Travel Policies in China , 2011 .

[14]  Kaustuva Acharya,et al.  Master–Slave Current-Sharing Control of a Parallel DC–DC Converter System Over an RF Communication Interface , 2008, IEEE Transactions on Industrial Electronics.

[15]  Paul Batty,et al.  Sustainable urban rail systems: strategies and technologies for optimal management of regenerative braking energy , 2013 .

[16]  K.. De Brabandere,et al.  A Voltage and Frequency Droop Control Method for Parallel Inverters , 2007, IEEE Transactions on Power Electronics.

[17]  Flavio Ciccarelli,et al.  Comparison of energy management control strategy based on wayside ESS for LRV application , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[18]  J. Van Mierlo,et al.  Improving energy efficiency in public transport: Stationary supercapacitor based Energy Storage Systems for a metro network , 2008, 2008 IEEE Vehicle Power and Propulsion Conference.

[19]  B. G. Fernandes,et al.  Modified droop controller for paralleling of dc-dc converters in standalone dc system , 2012 .

[20]  Johann W. Kolar,et al.  Parallel Connection of Two Three-Phase Three-Switch Buck-Type Unity-Power-Factor Rectifier Systems With DC-Link Current Balancing , 2007, IEEE Transactions on Industrial Electronics.

[21]  Azah Mohamed,et al.  Hybrid electric vehicles and their challenges: A review , 2014 .

[22]  J. Van Mierlo,et al.  Analysis and configuration of supercapacitor based energy storage system on-board light rail vehicles , 2008, 2008 13th International Power Electronics and Motion Control Conference.

[23]  T. Saich,et al.  China Urbanizes: Consequences, Strategies, and Policies , 2008 .

[24]  B. Lehman,et al.  A design method for paralleling current mode controlled DC-DC converters , 2004, IEEE Transactions on Power Electronics.

[25]  Huang Chang-fu,et al.  Research on the role of urban rail transit in promoting economic development , 2011 .

[26]  Yunfeng Huang Development of energy-saving buildings in China , 2011 .

[27]  Flavio Ciccarelli,et al.  Improvement of Energy Efficiency in Light Railway Vehicles Based on Power Management Control of Wayside Lithium-Ion Capacitor Storage , 2014, IEEE Transactions on Power Electronics.

[28]  Marc A. Rosen,et al.  Some Sustainability Aspects of Energy Conversion in Urban Electric Trains , 2010 .