Failure Mode Analysis and Protection of Non-Regenerative Three-level Boost Rectifier

This paper identifies a new fault type of non-regenerative three-level boost rectifiers (Vienna-type rectifiers), namely the dc-link voltage-doubling fault. Under this failure mode, the voltage across the dc-link capacitors is doubled when any of the ac switches in the neutral path of the converter is shorted, a unique behavior of three-level neutral-point clamped topologies. Addressing this, two types of protection methods are proposed, discussed and analyzed in this paper, the voltage clamping and the current breaking protection schemes. The impact of the ac inductors on the voltage-doubling phenomenon is studied carefully, and a guideline for the protection scheme selection is provided. This failure mode and the current breaking protection scheme are fully analyzed and verified by simulation and experimental results.

[1]  Longya Xu,et al.  Strategies of fault tolerant operation for three-level PWM inverters , 2006, IEEE Transactions on Power Electronics.

[2]  J. Pontt,et al.  High-power regenerative converter for ore transportation under failure conditions , 2004, IEEE Transactions on Industry Applications.

[3]  Chongming Qiao,et al.  Three-phase unity-power-factor star-connected switch (VIENNA) rectifier with unified constant-frequency integration control , 2003 .

[4]  James Patrick Lyons,et al.  Innovation IGCT main drives , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[5]  Thomas A. Lipo,et al.  Fault protection in a multilevel inverter implementation of a static condenser , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[6]  B. Francois,et al.  Design of a fault tolerant control system for a NPC multilevel inverter , 2002, Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on.

[7]  Giri Venkataramanan,et al.  Unity power factor control for three phase three level rectifiers without current sensors , 2005 .

[8]  Yan Deng,et al.  A multilevel converter topology with fault-tolerant ability , 2005, IEEE Transactions on Power Electronics.

[9]  Cursino B. Jacobina,et al.  Detection and compensation of switch faults in a three level inverter , 2006 .

[10]  Johann W. Kolar,et al.  A novel three-phase utility interface minimizing line current harmonics of high-power telecommunications rectifier modules , 1997, IEEE Trans. Ind. Electron..

[11]  H. Tuusa,et al.  Experimental results of vector controlled and vector modulated VIENNA I rectifier , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[12]  Hu Zhaoqing,et al.  Fuse protection of IGCTs against rupture in three-level commutated inverter , 2002, Proceedings. International Conference on Power System Technology.

[13]  Lei Hu,et al.  A multilevel converter topology with fault tolerant ability , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[14]  U. Drofenik,et al.  A new switching loss reduced discontinuous PWM scheme for a unidirectional three-phase/switch/level boost-type PWM (VIENNA) rectifier , 1999, 21st International Telecommunications Energy Conference. INTELEC '99 (Cat. No.99CH37007).

[15]  M.E. dos Santos,et al.  Short circuit and overcurrent protection of IGCT-based three-level NPC inverters , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[16]  Hirofumi Akagi,et al.  A New Neutral-Point-Clamped PWM Inverter , 1981, IEEE Transactions on Industry Applications.

[17]  J. K. Steinke,et al.  A reliable, interface-friendly medium voltage drive based on the robust IGCT and DTC technologies , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[18]  Bimal K. Bose,et al.  Investigation of fault modes of voltage-fed inverter system for induction motor drive , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[19]  Dong-Seok Hyun,et al.  Fault diagnosis and neutral point voltage control when the 3-level inverter faults occur , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).