Heat transfer characteristics and performance evaluation of water-cooled PV/T system with cooling channel above PV panel

Abstract A three-dimensional numerical model of water-cooled PV/T system with cooling channel above PV panel was built to analyze the influences of mass flow rate, cooling channel height, inlet water temperature and solar radiation intensity on heat transfer characteristics of cooling channel and performance of system. The Nusselt numbers of bottom and top surfaces of cooling channel were calculated, and the energy and exergy efficiencies of PV/T system were obtained. Results show that the Nusselt numbers of bottom and top surfaces perform opposite trend along the flow direction, and the convection heat transfer of bottom surface is better than that of top surface for almost all of cases. There is opposite direction of heat transfer within a certain distance from the entrance when inlet temperature of cooling medium is less than ambient temperature. As for system performance, both thermal efficiency and thermal exergy efficiency have greater variation amplitude when compared with electric efficiency and electric exergy efficiency respectively. The overall exergy efficiency of system achieves maximum at the mass flow rate of 0.003 kg/s and cooling channel height of 5 mm. Besides, the performance between the present system and traditional system was compared and some different conclusions have been drawn.

[1]  Faramarz Sarhaddi,et al.  Experimental investigation of exergy efficiency of a solar photovoltaic thermal (PVT) water collector based on exergy losses , 2015 .

[2]  Paolo Rosa-Clot,et al.  Experimental photovoltaic-thermal Power Plants based on TESPI panel , 2016 .

[3]  Ranko Goic,et al.  Fabrication, experimental study and testing of a novel photovoltaic module for photovoltaic thermal applications , 2016 .

[4]  Lan Xiao,et al.  A Review on the Methodology for Calculating Heat and Exergy Losses of a Conventional Solar PV/T System , 2015 .

[5]  A. Tiwari,et al.  Performance evaluation of hybrid PV/thermal water/air heating system: A parametric study , 2006 .

[6]  Arvind Tiwari,et al.  Performance evaluation of solar PV/T system: An experimental validation , 2006 .

[7]  Adel A. Hegazy,et al.  Comparative study of the performances of four photovoltaic/thermal solar air collectors. , 2000 .

[8]  Hasila Jarimi,et al.  Bi-fluid photovoltaic/thermal (PV/T) solar collector: Experimental validation of a 2-D theoretical model , 2016 .

[9]  Steve Sharples,et al.  Full-scale measurements of wind-induced convective heat transfer from a roof-mounted flat plate solar collector , 1998 .

[10]  Gianpiero Colangelo,et al.  Performance Evaluation of a New Type of Combined Photovoltaic–Thermal Solar Collector , 2015 .

[11]  Kamaruzzaman Sopian,et al.  Performance analysis of photovoltaic thermal (PVT) water collectors , 2014 .

[12]  Shafiqur Rehman,et al.  Performance evaluation of a PV (photovoltaic) module by back surface water cooling for hot climatic conditions , 2013 .

[13]  Andreas K. Athienitis,et al.  A Two-Dimensional Model of a Double-Façade With Integrated Photovoltaic Panels , 2006 .

[14]  Oussama Rejeb,et al.  A numerical investigation of a photovoltaic thermal (PV/T) collector , 2015 .

[15]  Kamaruzzaman Sopian,et al.  Performance analysis of PV/T Combi with water and air heating system: An experimental study , 2016 .

[16]  Mohammad Nurul Alam Hawlader,et al.  An active cooling system for photovoltaic modules , 2012 .

[17]  Andreas K. Athienitis,et al.  Convective Heat Transfer Coefficients in a Building-Integrated Photovoltaic/Thermal System , 2011 .

[18]  Kai Sirén,et al.  Performance evaluation and multi-objective optimization of hybrid photovoltaic–thermal collectors , 2014 .

[19]  N. Rahim,et al.  Effect of high irradiation and cooling on power, energy and performance of a PVT system , 2018 .

[20]  Cheng-Xian Lin,et al.  A review of PV–T systems: Thermal management and efficiency with single phase cooling , 2015 .

[21]  Mustafa İlkan,et al.  An experimental study on energy generation with a photovoltaic (PV)-solar thermal hybrid system , 2008 .

[22]  Arvind Tiwari,et al.  Exergy analysis of integrated photovoltaic thermal solar water heater under constant flow rate and constant collection temperature modes , 2009 .

[23]  Tzu-Chen Hung,et al.  Numerical analysis and experimental validation of heat transfer characteristic for flat-plate solar air collector , 2017 .

[24]  Marco Pellegrini,et al.  Photovoltaic/thermal (PV/T) solar system: Experimental measurements, performance analysis and economic assessment , 2017 .

[25]  L. Fara,et al.  Determination of the optimal operation mode of a flat solar collector by exergetic analysis and numerical simulation , 2005 .

[26]  Christian A. Gueymard,et al.  Generalized spectral performance evaluation of multijunction solar cells using a multicore, parallelized version of SMARTS , 2012 .

[27]  Liejin Guo,et al.  Preparation of highly dispersed nanofluid and CFD study of its utilization in a concentrating PV/T system , 2015 .

[28]  Ha Herbert Zondag,et al.  The yield of different combined PV-thermal collector designs , 2003 .