3D heart modelling from biplane, rotational angiocardiographic X-ray sequences

Abstract The 3DHeartView project produced an advanced software application for time-variant 3D cardiac modelling based on back projection of rotational X-ray angiographic sequences. Due to standard DICOM 3.0 interface, the software can be used as an add-on to any modern digital angiographer. The system accuracy has been measured and the approach has been validated with static and dynamic phantom object studies. The prototype has been tested in a clinical routine environment as well. In this paper we present the main features of the system, the methodology of 3D angiographic modelling, and certain testing and operation results. We also describe the application of high-performance computing technology in the modelling process.

[1]  P S Cho,et al.  Cone-beam CT from width-truncated projections. , 1996, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[2]  Michael Grass,et al.  3D rotational angiography: Clinical value in endovascular treatment , 1998 .

[3]  R Acharya Segmentation of multidimensional cardiac images. , 1995, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[4]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[5]  Jun Chen,et al.  Three-dimensional reconstruction of intracranial vessels from biplane projection views , 1996, Journal of Neuroscience Methods.

[6]  Klaus Mueller,et al.  Accelerating the anti-aliased algebraic reconstruction technique (ART) by table-based voxel backward projection , 1995, Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society.

[7]  I E Magnin,et al.  Image quality study in 3D X-ray angiography: a first approach using the experimental design strategy. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[8]  T. Takishima,et al.  Three-dimensional quantitative coronary angiography , 1990, IEEE Transactions on Biomedical Engineering.

[9]  Guido P. M. Prause,et al.  Binary reconstruction of the heart chambers from biplane angiographic image sequences , 1996, IEEE Trans. Medical Imaging.

[10]  H Wollschläger,et al.  Optimum angiographic visualization of coronary segments using computer-aided 3D-reconstruction from biplane views. , 1994, Computers and biomedical research, an international journal.

[11]  J Beier,et al.  Accuracy and precision of angiographic volumetry methods for left and right ventricle. , 1996, International journal of cardiology.

[12]  N Guggenheim,et al.  Spatial reconstruction of coronary arteries from angiographic images. , 1991, Physics in medicine and biology.

[13]  Y. Trousset,et al.  Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.