Fast neutrons detection in CR-39 and DAM–ADC nuclear track detectors

Abstract Fast detection of neutrons in CR-39 and DAM–ADC nuclear track detectors were investigated using new etching conditions. The neutron irradiation is performed using a 5 mCi Am–Be source present at the National Institute of Standards (NIS) of Egypt. Using the new etching condition, irradiated CR-39 samples were etched for 4 h and DAM-ADC samples for 80 min. Suitable analyzing software has been used to analyze experimental data.The dependence of neutrons track density on the neutrons fluence is investigated. When etched under optimum conditions, the relationship between track density and fluence is determined which is found to be linear. Detection efficiency has been represented for both SSNTDs and found to be constant with fluence, which reflects the importance of using CR-39 and DAM–ADC detectors in the field of neutron dosimetry. Linear relationship between track density and effective dose is determined.

[1]  Matiullah,et al.  Studying the response of CR-39 detectors using the Monte Carlo technique , 2001 .

[2]  G. Hassib Microdensitometric measurements of neutron-induced recoil tracks in plastic and their applications for fast neutron dosimetry , 1975 .

[3]  B. Dörschel,et al.  Neutron response calculation on the basis of variable track etch rates along the secondary particle trajectories in CR-39 , 1999 .

[4]  A. El-Sersy,et al.  Fast neutron spectroscopy using CR-39 track detectors , 2004 .

[5]  G. Marletta Chemical reactions and physical property modifications induced by keV ion beams in polymers , 1990 .

[6]  Vijay Kumar,et al.  Optimization of CR-39 as neutron dosimeter , 2010 .

[7]  D. Osorio,et al.  Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator , 2013 .

[8]  S. Djeffal,et al.  Characteristics of the CRS fast neutron personal dosemeter , 1997 .

[9]  G. Reitz,et al.  Personal neutron dosimetry in the space station MIR and the Space Shuttle. , 1999, Radiation measurements.

[10]  S. Nouh,et al.  Electrical, optical and structural behaviour of fast neutron-irradiation-induced CR-39 SSNTD , 2003 .

[11]  D. J. Brenner Conversion Coefficients for Use in Radiological Protection against External Radiation , 1999 .

[12]  O. Ashraf,et al.  The use of CH3OH additive to NaOH for etching alpha particle tracks in a CR-39 plastic nuclear track detector , 2014 .

[13]  T. Tsuruta,et al.  Diallyl maleate homopolymer and its copolymers containing allyl diglycol carbonate as nuclear track detector , 2011 .

[14]  A. N. Sosnin,et al.  Determination of energetic neutron spatial distribution using neutron induced nuclear recoil events , 2002 .

[15]  T. Tsuruta,et al.  Etching characteristic studies for the detection of alpha particles in DAM–ADC nuclear track detector , 2014 .