The Influence of the Insertion Technique on the Pullout Force of Pedicle Screws: An Experimental Study

Study Design. The pullout strength of a typical pedicle screw was evaluated experimentally for different screw insertion techniques. Objective. To conclude whether the self-tapping insertion technique is indeed the optimum one for self-tapping screws, with respect to the pullout strength. Summary of Background Data. It is reported in the literature that the size of the pilot-hole significantly influences the pullout strength of a self-tapping screw. In addition it is accepted that an optimum value of the diameter of the pilot-hole exists. For non self-tapping screw insertion it is reported that undertapping of the pilot-hole can increase its pullout strength. Finally it is known that in some cases orthopedic surgeons open the threaded holes, using another screw instead of a tap. Methods. A typical commercial self-tapping pedicle screw was inserted into blocks of Solid Rigid Polyurethane Foam (simulating osteoporotic cancellous bone), following different insertion techniques. The pullout force was measured according to the ASTM-F543–02 standard. The screw was inserted into previously prepared holes of different sizes, either threaded or cylindrical, to conclude whether an optimum size of the pilot-hole exists and whether tapping can increase the pullout strength. The case where the tapping is performed using another screw was also studied. Results. For screw insertion with tapping, decreasing the outer radius of the threaded hole from 1.00 to 0.87 of the screw's outer radius increased the pullout force 9%. For insertion without tapping, decreasing the pilot-hole's diameter from 0.87 to 0.47 of the screw's outer diameter increased its pullout force 75%. Finally, tapping using another screw instead of a tap, gave results similar to those of conventional tapping. Conclusion. Undertapping of a pilot-hole either using a tap or another screw can increase the pullout strength of self-tapping pedicle screws.

[1]  G. Njus,et al.  Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone. , 2008, The Journal of trauma.

[2]  Serkan Inceoğlu,et al.  Screw design alters the effects of stress relaxation on pullout. , 2008, Bio-medical materials and engineering.

[3]  J. Szivek,et al.  Pullout Strengths of Cannulated and Noncannulated Cancellous Bone Screws , 1997, Clinical orthopaedics and related research.

[4]  K. Gerlach,et al.  Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws. , 1998, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[5]  Bryan P Conrad,et al.  Biomechanical Evaluation of the Pullout Strength of Cervical Screws , 2005, Journal of spinal disorders & techniques.

[6]  F. Pfeiffer,et al.  A Comparison of Pullout Strength for Pedicle Screws of Different Designs: A Study Using Tapped and Untapped Pilot Holes , 2006, Spine.

[7]  J. Torner,et al.  Factors Affecting the Pullout Strength of Self-Drilling and Self-Tapping Anterior Cervical Screws , 2003, Spine.

[8]  B. T. Field,et al.  A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. , 1986, Clinical orthopaedics and related research.

[9]  N. Crawford,et al.  Comparative Pull-Out Strength of Tapped and Untapped Pilot Holes for Bicortical Anterior Cervical Screws , 1997, Spine.

[10]  Peter Augat,et al.  Influence of thread design on pedicle screw fixation. Laboratory investigation. , 2008, Journal of neurosurgery. Spine.

[11]  C. E. Bowman,et al.  Holding power of orthopedic screws in bone. , 1970, Clinical orthopaedics and related research.

[12]  E. Benzel,et al.  Effects of hole preparation on screw pullout resistance and insertional torque: a biomechanical study. , 2001, Journal of neurosurgery.

[13]  C. Reitman,et al.  Biomechanical Evaluation of Relationship of Screw Pullout Strength, Insertional Torque, and Bone Mineral Density in the Cervical Spine , 2004, Journal of spinal disorders & techniques.

[14]  D R Carter,et al.  In vitro evaluation of the loosening characteristics of self-tapped and non-self-tapped cortical bone screws. , 1981, Clinical orthopaedics and related research.

[15]  J. P. Paul,et al.  Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation. , 2003, Medical engineering & physics.

[16]  R H Ansell,et al.  A study of some factors which affect the strength of screws and their insertion and holding power in bone. , 1968, Journal of biomechanics.

[17]  X. Weng,et al.  [Complications associated with the technique of pedicle screw fixation]. , 2002, Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae.

[18]  J. Mogaard,et al.  How pilot-hole size affects bone-screw pullout strength in human cadaveric cancellous bone. , 2005, Canadian journal of surgery. Journal canadien de chirurgie.

[19]  G. Njus,et al.  The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone. , 2008, The Journal of trauma.

[20]  Motoki Iwasaki,et al.  Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients. , 2006, Journal of neurosurgery. Spine.

[21]  S. Cook,et al.  Effects of Bone Mineral Density on Pedicle Screw Fixation , 1994, Spine.

[22]  G. Njus,et al.  Pullout Strength of Self-Tapping Screws Inserted to Different Depths , 2005, Journal of orthopaedic trauma.

[23]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[24]  W. Hayes,et al.  Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. , 1993, Clinical orthopaedics and related research.