A combined atomic force microscopy and nanoindentation technique to investigate the elastic properties of bone structural units.

To our knowledge, this study applied for the first time a recently developed combination of atomic force microscopy (AFM) and nanoindentation on trabecular and compact bone tissue. The major aim was to check the advantage of the available AFM-mode over the conventionally used optical microscope. First, we investigated if removal of the water content helped to prevent enzymatic degradation of the bone tissue and preserve its mechanical properties during a week. After the positive issue of this test, we quantified the intrinsic mechanical properties of single bone structural units (BSU). Bone specimens were obtained from the femoral neck of an 86 year old female. Four BSU were randomly selected and tested each with 24 indents of 5 mN maximum force. The available AFM mode proved to be a very useful tool for surface characterization and precise selection of the indentation area. The elastic modulus ranged from 18 -/+ 1.7 GPa for a BSU of compact bone to 22.5 -/+ 3.1 GPa for a BSU of trabecular bone. Hardness showed values between 0.6 -/+ 0.11 GPa for compact bone and 1.1 -/+ 0.17 GPa for trabecular bone. The results suggest that the micromechanics of bone tissue may also be described as an assembly of distinct structural units with rather homogeneous material properties.

[1]  J Y Rho,et al.  Elastic properties of microstructural components of human bone tissue as measured by nanoindentation. , 1999, Journal of biomedical materials research.

[2]  J. L. Williams,et al.  Tensile testing of rodlike trabeculae excised from bovine femoral bone. , 1989, Journal of biomechanics.

[3]  S. Goldstein,et al.  The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus. , 1990, Journal of biomechanics.

[4]  C. Hirsch,et al.  Factors affecting the determination of the physical properties of femoral cortical bone. , 1966, Acta orthopaedica Scandinavica.

[5]  G. Pharr,et al.  Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. , 1997, Biomaterials.

[6]  J. Lewis,et al.  Experimental method for the measurement of the elastic modulus of trabecular bone tissue , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  G. Pharr,et al.  Effects of drying on the mechanical properties of bovine femur measured by nanoindentation , 1999, Journal of materials science. Materials in medicine.

[8]  W. Hayes,et al.  Morphology-mechanical property relations in trabecular bone of the osteoarthritic proximal tibia. , 1994, The Journal of arthroplasty.

[9]  R. Rose,et al.  Buckling studies of single human trabeculae. , 1975, Journal of biomechanics.

[10]  R. B. Ashman,et al.  Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. , 1993, Journal of biomechanics.

[11]  J. Currey,et al.  Microhardness and Young's modulus in cortical bone exhibiting a wide range of mineral volume fractions, and in a bone analogue , 1990 .

[12]  J. Currey,et al.  The mechanical consequences of variation in the mineral content of bone. , 1969, Journal of biomechanics.

[13]  I. N. Sneddon The relation between load and penetration in the axisymmetric boussinesq problem for a punch of arbitrary profile , 1965 .

[14]  G. Pharr,et al.  Mechanical and morphological variation of the human lumbar vertebral cortical and trabecular bone. , 1999, Journal of biomedical materials research.

[15]  G. Pharr,et al.  An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments , 1992 .

[16]  A. Meunier,et al.  Scanning acoustic microscope studies of the elastic properties of osteons and osteon lamellae. , 1993, Journal of biomechanical engineering.

[17]  S. Goldstein,et al.  Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur. , 1999, Journal of biomechanics.

[18]  S. Weiner,et al.  Microstructure-microhardness relations in parallel-fibered and lamellar bone. , 1996, Bone.