Ammonia Emissions from Broiler Houses in the Southeastern United States

Continuous monitoring of ammonia (NH3) emissions from two mechanically ventilated commercial broiler houses located in the southeastern United States was performed during a one-year period over 2005-2006 as a joint effort between Iowa State University and the University of Kentucky. Ammonia concentrations were measured using Innova 1412 photoacoustic NH3 monitors. Ventilation rates in each house were measured continuously by monitoring the building static pressure and operational status of all ventilation fans in conjunction with individual performance curves developed and verified in situ using a Fan Assessment Numeration System (FANS) unit. Expressed in various units, NH3 emissions from the two broiler houses over the one-year production period were of the following values: a) 35.4 g per bird marketed (77.9 lb per 1,000 birds marketed), including both grow-out (50-54 d per flock) and downtime (12-25 d between flocks) emissions; b) annual (365-d) emission of 4.63 Mg (5.1 US tons) per house, including both grow-outs and downtime; c) maximum grow-out daily emission of 30.6 kg/d-house (67.4 lb/d-house) for one house and 35.5 kg/d-house (78.2 lb/d-house) for the other; d) mean grow-out daily emission of 14.0 ± 9.1 ( S.D.) kg/d-house; e) mean downtime daily emission of 8.8 ± 8.3 kg/d-house. Flocks on new bedding had a lower emission rate of 12.4 ± 9.4 kg/d-house, as compared to 14.5 ± 8.9 kg/d-house for flocks on built-up litter. The NH3 emission factor of 35.4 g/bird marketed from this study is substantially lower than that cited by US EPA of 100 g/yr-bird (the US EPA yr-bird unit is equivalent to bird marketed).

[1]  Lara B. Moody,et al.  Monitoring system design for the southeastern broiler gaseous and particulate matter air emissions monitoring project , 2006 .

[2]  Hongwei Xin,et al.  Method for Measuring Ammonia Emissions from Poultry Houses , 2005 .

[3]  B. Nicks,et al.  Emissions of ammonia, nitrous oxide, methane, carbon dioxide and water vapor in the raising of weaned pigs on straw-based and sawdust-based deep litters , 2003 .

[4]  Hongwei Xin,et al.  Ammonia Emissions from Twelve U.S. Broiler Chicken Houses , 2006 .

[5]  S. Zelmanowitz,et al.  Development and selection of ammonia emission factors for the 1985 NAPAP emissions inventory. Final report, August 1987-December 1989 , 1990 .

[6]  G. Hörnig,et al.  Possibilities for Reducing Gas-Emission of Animal Husbandry , 2005 .

[7]  C. Copeland Air Quality Issues and Animal Agriculture: EPA's Air Compliance Agreement [July 20, 2012] , 2008 .

[8]  Thomas P. Minka,et al.  Gates , 2008, NIPS.

[9]  Lara B. Moody,et al.  Quality Assurance Project Plan (QAPP) for monitoring gaseous and particulate matter emissions from southeastern broiler houses , 2006 .

[10]  Calvin B. Parnell,et al.  PARTICULATE MATTER AND AMMONIA EMISSION FACTORS FOR TUNNEL–VENTILATED BROILER PRODUCTION HOUSES IN THE SOUTHERN U.S. , 2003 .

[11]  R. Siefert,et al.  Characterization of atmospheric ammonia emissions from a commercial chicken house on the Delmarva Peninsula. , 2004, Environmental science & technology.

[12]  Lara B. Moody,et al.  Southeastern Broiler Gaseous and Particulate Matter Emissions Monitoring , 2009 .

[13]  John D. Simmons,et al.  Fan Assessment Numeration System (FANS) Design and Calibration Specifications , 2002 .