Adaptive Multifocus Beamforming for Contrast-Enhanced-Super-Resolution Ultrasound Imaging in Deep Tissue

Contrast-enhanced-super-resolution ultrasound imaging, also referred to as ultrasound localization microscopy, can resolve vessels that are smaller than the diffraction limit and has recently been able to generate super-resolved vascular images of shallow in vivo structures in small animals. To fully translate this technology to the clinic, it is advantageous to be able to detect microbubbles at deeper locations in tissue while maintaining a short acquisition time. Current implementations of this imaging method rely on plane-wave imaging. This method has the advantage of maximizing the frame rate, which is important due to the large amount of frames required for super-resolution processing. However, the wide planar beam used to illuminate the field of view produces poor contrast and low sensitivity bubble detection. Here, we propose an “adaptive multifocus” sequence, a new ultrasound imaging sequence that combines the high frame rate feature of a plane wave with the increased bubble detection sensitivity of a focused beam. This sequence simultaneously sonicates two or more foci with a single emission, hence retaining a high frame rate, yet achieving improved sensitivity to microbubbles. In the limit of one target, the beam reduces to a conventional focused transmission; and for an infinite number of targets, it converges to plane-wave imaging. Numerical simulations, using the full-wave code, are performed to compare the point spread function of the proposed sequence to that generated by the plane-wave emission. Our numerical results predict an improvement of up to 15 dB in the signal-to-noise ratio. Ex vivo experiments of a tissue-embedded microtube phantom are used to generate super-resolved images and to compare the adaptive beamforming approach to plane-wave imaging. These experimental results show that the adaptive multifocus sequence successfully detects 744 microbubble events at 60 mm when they are undetectable by the plane-wave sequence under the same imaging conditions. At a shallower depth of 44 mm, the proposed adaptive multifocus method detects 6.9 times more bubbles than plane-wave imaging (1763 versus 257 bubble events).

[1]  J. Folkman Tumor angiogenesis: therapeutic implications. , 1971, The New England journal of medicine.

[2]  D. Hanahan,et al.  The Hallmarks of Cancer , 2000, Cell.

[3]  Paul A Dayton,et al.  Quantitative Volumetric Perfusion Mapping of the Microvasculature Using Contrast Ultrasound , 2010, Investigative radiology.

[4]  G. Trahey,et al.  Sources of image degradation in fundamental and harmonic ultrasound imaging using nonlinear, full-wave simulations , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Robert J. Eckersley,et al.  In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles , 2015, IEEE Transactions on Medical Imaging.

[6]  Georg Schmitz,et al.  Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[7]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Paul A Dayton,et al.  Quantification of Microvascular Tortuosity during Tumor Evolution Using Acoustic Angiography. , 2015, Ultrasound in medicine & biology.

[9]  Paul A Dayton,et al.  High-resolution, high-contrast ultrasound imaging using a prototype dual-frequency transducer: In vitro and in vivo studies , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  J. Lippincott-Schwartz,et al.  Imaging Intracellular Fluorescent Proteins at Nanometer Resolution , 2006, Science.

[11]  Paul A. Dayton,et al.  3-D Ultrasound Localization Microscopy for Identifying Microvascular Morphology Features of Tumor Angiogenesis at a Resolution Beyond the Diffraction Limit of Conventional Ultrasound , 2017, Theranostics.

[12]  Frédéric Wintzenrieth,et al.  Contrast enhanced ultrasound by real-time spatiotemporal filtering of ultrafast images , 2017, Physics in medicine and biology.

[13]  Jan D'hooge,et al.  Multi-transmit beam forming for fast cardiac imaging-a simulation study , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[14]  Paul A. Dayton,et al.  Super resolution contrast ultrasound imaging: Analysis of imaging resolution and application to imaging tumor angiogenesis , 2016, 2016 IEEE International Ultrasonics Symposium (IUS).

[15]  M. Fink,et al.  Microbubble ultrasound super-localization imaging (MUSLI) , 2011, 2011 IEEE International Ultrasonics Symposium.

[16]  G. Trahey,et al.  A heterogeneous nonlinear attenuating full- wave model of ultrasound , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[18]  J Bercoff,et al.  Ultrafast compound doppler imaging: providing full blood flow characterization , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  Gianmarco Pinton,et al.  Ultrasound imaging of the human body with three dimensional full-wave nonlinear acoustics. Part 1: simulations methods , 2020, 2003.06934.

[20]  C Dunsby,et al.  Acoustic super-resolution with ultrasound and microbubbles , 2013, Physics in medicine and biology.

[21]  Meaghan A. O'Reilly,et al.  A super-resolution ultrasound method for brain vascular mapping. , 2013, Medical physics.

[22]  Paul A Dayton,et al.  Mapping microvasculature with acoustic angiography yields quantifiable differences between healthy and tumor-bearing tissue volumes in a rodent model. , 2012, Radiology.

[23]  F. Duck Physical properties of tissue , 1990 .

[24]  Piero Tortoli,et al.  Multi-Transmit Beam Forming for Fast Cardiac Imaging—Experimental Validation and In Vivo Application , 2014, IEEE Transactions on Medical Imaging.

[25]  M. Tanter,et al.  Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging , 2015, Nature.

[26]  Paul A Dayton,et al.  Optimizing Sensitivity of Ultrasound Contrast-Enhanced Super-Resolution Imaging by Tailoring Size Distribution of Microbubble Contrast Agent. , 2017, Ultrasound in medicine & biology.

[27]  Mickael Tanter,et al.  Sono-activated ultrasound localization microscopy , 2013 .

[28]  Raoul Mallart,et al.  Improved imaging rate through simultaneous transmission of several ultrasound beams , 1992, SPIE Optics + Photonics.

[29]  Charlie Demené,et al.  Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity , 2015, IEEE Transactions on Medical Imaging.

[30]  Michael J Rust,et al.  Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) , 2006, Nature Methods.