Percutaneous mitral valve dilatation with the multi‐track system

We developed the Multi‐Track System for percutaneous mitral valvotomy and described the preliminary results in 1995. Here we report the first 100 consecutive cases after the original publication. Two separate balloon catheters are positioned on a single guidewire. The first catheter, with only a distal guidewire lumen, is introduced into the vein and then advanced into the mitral orifice. Subsequently, a rapid exchange balloon catheter running on the same guidewire is inserted and lined up with the first catheter so the two are positioned side by side. Both balloons are then inflated simultaneously. Age of the patients was 31 ± 12.8 years and weight 50 ± 14 kg. Valve area increased 0.75 ± 0.22 cm2 to 2.00 ± 0.32 cm2and mean left atrial pressure dropped from 27 ± 8 to 11 ± 5 mm Hg. One patient had significant mitral insufficiency after dilatation, which did not require surgery. The Multi‐Track System is a valid alternative to the existing procedures for the treatment of mitral stenosis and uses simpler and less costly catheters. Cathet. Cardiovasc. Intervent. 48:178–183, 1999. © 1999 Wiley‐Liss, Inc.

[1]  I. Palacios Farewell to surgical mitral commissurotomy for many patients. , 1998, Circulation.

[2]  A. Cribier,et al.  Percutaneous mitral valvotomy with a metal dilatator , 1997, The Lancet.

[3]  S. Rahimtoola,et al.  Actuarial outcome after catheter balloon commissurotomy in patients with mitral stenosis. , 1997, Circulation.

[4]  P. Bonhoeffer,et al.  Mitral dilatation with the Multi-Track system: an alternative approach. , 1995, Catheterization and cardiovascular diagnosis.

[5]  J. Carroll,et al.  Effect of atrial septal occlusion on mitral area after Inoue balloon valvotomy. , 1994, Catheterization and cardiovascular diagnosis.

[6]  Seung‐Jung Park,et al.  Immediate and one-year results of percutaneous mitral balloon valvuloplasty using Inoue and double-balloon techniques. , 1993, American Journal of Cardiology.

[7]  A. Saxena,et al.  Comparison of immediate hemodynamic response to closed mitral commissurotomy, single-balloon, and double-balloon mitral valvuloplasty in rheumatic mitral stenosis. , 1992, The Journal of thoracic and cardiovascular surgery.

[8]  C. Ruiz,et al.  Transseptal catheterization update 1992. , 1992, Catheterization and cardiovascular diagnosis.

[9]  J. Hill,et al.  The M-Heart percutaneous balloon mitral Valvuloplasty Registry: initial results and early follow-up. The M-Heart Group. , 1990, Journal of the American College of Cardiology.

[10]  J. Allen,et al.  Percutaneous double balloon valvotomy for severe rheumatic mitral stenosis. , 1990, The American journal of cardiology.

[11]  T. Cheng,et al.  Comparison of single rubber-nylon balloon and double polyethylene balloon valvuloplasty in 94 patients with rheumatic mitral stenosis. , 1990, American heart journal.

[12]  I. Palacios,et al.  Follow-up of patients undergoing percutaneous mitral balloon valvotomy. Analysis of factors determining restenosis. , 1989, Circulation.

[13]  P. Ribeiro,et al.  One-year follow-up after percutaneous double balloon mitral valvotomy. , 1989, The American journal of cardiology.

[14]  I. Palacios,et al.  Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. , 1988, British heart journal.

[15]  P. Ribeiro,et al.  Mechanism of mitral valve area increase by in vitro single and double balloon mitral valvotomy. , 1988, The American journal of cardiology.

[16]  I. Palacios,et al.  Percutaneous balloon mitral valvotomy for patients with mitral stenosis. Analysis of factors influencing early results. , 1988, The Journal of thoracic and cardiovascular surgery.

[17]  T. Cheng,et al.  Percutaneous transseptal balloon mitral valvuloplasty: the Chinese experience in 30 patients. , 1988, American heart journal.

[18]  C. McKay,et al.  Improvement in exercise capacity and exercise hemodynamics 3 months after double-balloon, catheter balloon valvuloplasty treatment of patients with symptomatic mitral stenosis. , 1988, Circulation.

[19]  I. Palacios,et al.  Mitral balloon valvuloplasty for mitral restenosis after surgical commissurotomy. , 1988, Journal of the American College of Cardiology.

[20]  I. Palacios,et al.  Mitral regurgitation after percutaneous balloon mitral valvuloplasty in adults: evaluation by pulsed Doppler echocardiography. , 1988, Journal of the American College of Cardiology.

[21]  A. Berman,et al.  Balloon dilation of mitral stenosis in adult patients: postmortem and percutaneous mitral valvuloplasty studies. , 1987, Journal of the American College of Cardiology.

[22]  I. Palacios,et al.  Percutaneous balloon valvotomy for patients with severe mitral stenosis. , 1987, Circulation.

[23]  P. Ribeiro,et al.  PERCUTANEOUS DOUBLE-BALLOON MITRAL VALVOTOMY FOR RHEUMATIC MITRAL-VALVE STENOSIS , 1986, The Lancet.

[24]  J. F. Keane,et al.  Percutaneous catheter commissurotomy in rheumatic mitral stenosis. , 1985, The New England journal of medicine.

[25]  K Inoue,et al.  Clinical application of transvenous mitral commissurotomy by a new balloon catheter. , 1984, The Journal of thoracic and cardiovascular surgery.

[26]  Flear Ct Letter: Intravenous feeding. , 1974, Lancet.