Biomechanical study of different plate configurations for distal humerus osteosynthesis

Fractures of the distal humerus are most commonly fixed by open reduction and internal fixation, using plates and screws, either in a locking or in a non-locking construct. Three different plating systems are commonly used in practice. The most important differences between them are in plate orientation, which affects both the rigidity of the osteosynthesis and invasiveness of the surgical procedure. Unfortunately, there is no common agreement between surgeons about which plate configuration brings the best clinical outcome. In this study, we investigate the theoretical rigidity of plate osteosyntheses considering two types of AO/ASIF configurations (90° angle between plates), Mayo clinic (Acumed) configuration (180° between plates) and dorsal fixation of both plates. We also compared the results for cases with and without contact between the bone fragments. In the case of no bone contact, the Mayo clinic plate configuration is found to be the most rigid, followed by both AO/ASIF plate configurations, and the least rigid system is the Korosec plate configuration. On the other hand, no significant differences between all types of fixation configurations are found in cases with contact in-between the bone fragments. Our findings show that this contact is very important and can compensate for the lack of load carrying capacity of the implants. This could therefore incite other implant fixation solutions, leading to less invasive surgical procedures and consequently improved clinical outcome.

[1]  Daniel Baumgartner,et al.  Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture , 2009, Medical & Biological Engineering & Computing.

[2]  Chun-Li Lin,et al.  Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture. , 2007, Clinical biomechanics.

[3]  R. Huston Principles of Biomechanics , 2008 .

[4]  F. Netter Atlas of Human Anatomy , 1967 .

[5]  S. O’Driscoll,et al.  Optimizing stability in distal humeral fracture fixation. , 2005, Journal of shoulder and elbow surgery.

[6]  R. Hughes,et al.  Changes in the long head of the biceps tendon in rotator cuff tear shoulders. , 2005, Clinical biomechanics.

[7]  A. Gefen,et al.  Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws , 2002, Medical and Biological Engineering and Computing.

[8]  Pascal Drazetic,et al.  On the Mechanical Characterization of Human Humerus using Multi-scale Continuum Finite Element Model , 2012 .

[9]  P. Augat,et al.  Effects of construct stiffness on healing of fractures stabilized with locking plates. , 2010, The Journal of bone and joint surgery. American volume.

[10]  R. Bošnjak,et al.  Subperiosteal elevation of the ulnar nerve-Anatomical considerations and preliminary results. , 2008, Injury.

[11]  A. Mahar,et al.  Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures. , 2006, Clinical biomechanics.

[12]  R. Major Biomechanics of the Musculo-Skeletal System , 1994 .

[13]  James A. Johnson,et al.  Mechanical properties of cancellous bone of the distal humerus. , 2005, Clinical biomechanics.

[14]  Clem W. Thompson Manual of structural kinesiology , 1969 .

[15]  C. Zalavras,et al.  Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures. , 2011, Journal of shoulder and elbow surgery.

[16]  E. Schneider,et al.  A Biomechanical Evaluation of Methods of Distal Humerus Fracture Fixation Using Locking Compression Plates Versus Conventional Reconstruction Plates , 2004, Journal of orthopaedic trauma.

[17]  B. Nigg,et al.  Biomechanics of the musculo-skeletal system , 1995 .

[18]  Peter Augat,et al.  Anatomical plate configuration affects mechanical performance in distal humerus fractures. , 2010, Clinical biomechanics.

[19]  C. R. Ethier,et al.  Introductory Biomechanics: From Cells to Organisms , 2007 .

[20]  Scott T. Lovald,et al.  Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[21]  Robert Souffrant,et al.  Finite Element Analysis of Osteosynthesis Screw Fixation in the Bone Stock: An Appropriate Method for Automatic Screw Modelling , 2012, PloS one.

[22]  Joseph Hamill,et al.  Biomechanical Basis of Human Movement , 1995 .

[23]  Frans C. T. van der Helm,et al.  Development of a comprehensive musculoskeletal model of the shoulder and elbow , 2011, Medical & Biological Engineering & Computing.

[24]  E. Schneider,et al.  The LCP-concept in the operative treatment of distal humerus fractures--biological, biomechanical and surgical aspects. , 2003, Injury.

[25]  E. B. de Las Casas,et al.  Standard of disocclusion in complete dentures supported by implants without free distal ends: analysis by the finite elements method , 2012, Journal of applied oral science : revista FOB.

[26]  Pankaj Pankaj,et al.  Does screw-bone interface modelling matter in finite element analyses? , 2012, Journal of biomechanics.

[27]  Ching-Lung Tai,et al.  Biomechanical optimization of different fixation modes for a proximal femoral L-osteotomy , 2009, BMC musculoskeletal disorders.

[28]  H. Naceur,et al.  Multiscale modelling of the mechanical behaviour of human humerus under impact , 2013, Computer methods in biomechanics and biomedical engineering.

[29]  Sang-Jin Shin,et al.  A clinical comparison of two different double plating methods for intraarticular distal humerus fractures. , 2010, Journal of shoulder and elbow surgery.

[30]  Edward K. Chadwick,et al.  Clinical applications of musculoskeletal modelling for the shoulder and upper limb , 2013, Medical & Biological Engineering & Computing.

[31]  C. Carroll Subperiosteal elevation of the ulnar nerve during internal fixation for fractures of the distal humerus assessed by intra-operative neurophysiological monitoring , 2007 .

[32]  S. Woo,et al.  Mechanical properties of the long head of the biceps tendon , 2005, Knee Surgery, Sports Traumatology, Arthroscopy.

[33]  Eugene C. Rembe Manual of Structural Kinesiology. 6th ed , 1970 .