Optical simulations for the Wolter-I collimator in the VERT-X calibration facility

The VERT-X X-ray calibration facility, currently in prototypal realization phase supported by ESA, will be a vertical X-ray beamline able to test and calibrate the entire optical assembly of the ATHENA X-ray telescope. Owing to its long focal length (12 m), a full-illumination test of the entire focusing system would require a parallel and uniform X-ray beam as large as the optical assembly itself (2.5 m). Moreover, the module should better be laid parallel to the ground in order to minimize the effects of gravity deformations. Therefore, the ideal calibration facility would consist of a vertical beam, with the source placed at very large distance (>> 500 m) under high vacuum (10-6 mbar). Since such calibration systems do not exist, and also appear to be very hard to manufacture, VERT-X will be based on a different concept, i.e., the raster scan of a tightly (≈ 1 arcsec) collimated X-ray beam, generated by a microfocus source and made parallel via a precisely shaped Wolter-I mirror. In this design, the mirror will be made of two segments (paraboloid + hyperboloid) that, for the X-ray beam collimation to be preserved, will have to be accurately finished and maintain their mutual alignment to high accuracy during the scan. In this paper, we show simulations of the reflected wavefront based on physical optics and the expected final imaging quality, for different polishing levels and misalignments for the two segments of the VERT-X collimator.

[1]  M. Uslenghi,et al.  Building the BEaTriX facility for the ATHENA mirror modules X-ray testing , 2021, Optical Engineering + Applications.

[2]  D. Spiga,et al.  Manufacturing and testing of the X-ray collimating mirror for the BEaTriX facility , 2021, Optical Engineering + Applications.

[3]  Daniele Spiga,et al.  Simulating the optical performances of the LCLS bendable mirrors using a 2D physical optics approach , 2018, Optical Engineering + Applications.

[4]  Maximilien J. Collon,et al.  Testing ATHENA optics: a new measurement standard at the PANTER x-ray test facility , 2021, International Conference on Space Optics.

[5]  Daniele Spiga,et al.  Analytical evaluation of the X-ray scattering contribution to imaging degradation in grazing-incidence X-ray telescopes , 2007 .

[6]  Marco Beijersbergen,et al.  X-ray mirror development and production for the Athena telescope , 2021, International Conference on Space Optics.

[7]  D. Spiga,et al.  X-ray optical systems: from metrology to Point Spread Function , 2014 .

[8]  M. Uslenghi,et al.  The VERT-X calibration facility: development of the most critical parts , 2021, Optical Engineering + Applications.

[9]  G. Pareschi,et al.  Facility for alignment, assembly, and integration of the SPO mirror modules onto the ATHENA telescope , 2021, Optical Engineering + Applications.

[10]  D. Spiga,et al.  Open-source simulator for ATHENA X-ray telescope optics , 2021, Optical Engineering + Applications.

[11]  M. Bavdaz,et al.  VERT-X: VERTical X-ray raster-scan facility for ATHENA calibration. The concept design. , 2019, Optics for EUV, X-Ray, and Gamma-Ray Astronomy IX.

[12]  D. Spiga,et al.  Optical simulations for design, alignment, and performance prediction of silicon pore optics for the ATHENA x-ray telescope (Conference Presentation) , 2017, Optical Engineering + Applications.

[13]  Marcos Bavdaz,et al.  The Athena x-ray optics development and accommodation , 2021, International Conference on Space Optics.

[14]  Daniele Spiga,et al.  Mirrors for X-ray telescopes: Fresnel diffraction-based computation of point spread functions from metrology , 2014, 1409.1750.