Heat Recovery for a Textile Stenter: CFD Analysis of Air Curtain Benefits

Modern textile stenters are designed to reduce the inefficiency of the process and to recover the flow stream, which still contains a relatively high energetic value. In recent years, research has focused on the recovery of the energy content of the low-temperature exhaust flow; nonetheless, another important aspect that may increase the efficiency of the process is the reduction of the ambient air suction. In the present research, an innovative way to improve both machine insulation and energy savings, by using preheated air, was numerically evaluated. The proposed solution utilizes an air stream transverse to the fabric (generally called air curtain), either preheated or not, to create soft gates both at the inlet and at the outlet section of the drying machine. Several valuable advantages can be listed when using this solution: reduction of the dispersion of heat and humid polluted air to the work environment, limitation of air ingestion from outside, and effective heat recovery coupled to a uniform temperature profile around the textile fabric. To analyze the insulation capability of the air curtains in terms of mass and energy transfer, a two-dimensional CFD model of the machine was realized. A test matrix including three possible fabric speeds (20, 40 and 60 m/min), three tilt angles (−15°, 0° and 15°), four mass flow rates (0% with no air curtains and 3%, 5% and 7% of the total flow rate through the machine, where the 5% case is equivalent to the flow rate ingested from the ambient) and two temperatures (15 °C and 70 °C) of the plane jets exiting from the air curtains was considered, thus covering a wide range of possible practical applications. The obtained results demonstrate that warm air curtains at both the inlet and outlet are very effective in a fabric speed range up to 40 m/min; at higher fabric speed, entrainment of warm gases from inside the machine at the fabric outlet becomes relevant, and the adoption of a cold air curtain (capable of better insulation) can be recommended in this position.

[1]  Bart Merci,et al.  Experimental study of the effectiveness of air curtains of variable width and injection angle to block fire-induced smoke in a tunnel configuration , 2018, International Journal of Thermal Sciences.

[2]  Shyamika Shiwanthi,et al.  Evaluation of the environmental and economic performances of three selected textile factories in Biyagama Export Processing Zone Sri Lanka , 2018, Environmental Development.

[3]  Henk Huisseune,et al.  Heat Transfer Through Vertically Downward-Blowing Single-Jet Air Curtains for Cold Rooms , 2012 .

[4]  P. Rhodes Administration. , 1983 .

[5]  J. Moureh,et al.  Numerical and experimental investigations on jet characteristics and airflow patterns related to an air curtain subjected to external lateral flow. , 2016 .

[6]  R. Tuğrul Oğulata,et al.  Utilization of waste-heat recovery in textile drying , 2004 .

[7]  Juan Carlos Ramos,et al.  Towards cooling systems integration in buildings: Experimental analysis of a heat dissipation panel , 2017 .

[8]  Arif Hepbasli,et al.  Exergetic Analysis of Textile Convective Drying with Stenters by Subsystem Models: Part 2—Parametric Study on Exergy Analysis , 2010 .

[9]  Ali Hasanbeigi,et al.  A Review of Energy Use and Energy Efficiency Technologies for the Textile Industry , 2012 .

[10]  Arif Hepbasli,et al.  Exergetic Analysis of Textile Convective Drying with Stenters by Subsystem Models: Part 1—Exergetic Modeling and Evaluation , 2010 .

[11]  A. M. Foster,et al.  Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration , 2006 .

[12]  A. R. Figueiredo,et al.  Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches , 2012 .

[13]  Muhiddin Can,et al.  Waste-heat recovery potential in Turkish textile industry: Case study for city of Bursa , 2009 .

[14]  Chia-Jung Hsu Numerical Heat Transfer and Fluid Flow , 1981 .

[15]  Arif Hepbasli,et al.  A study on the exergetic analysis of continuous textile dryers , 2009 .

[16]  Daniele Fiaschi,et al.  Improvement of waste heat recuperation on an industrial textile dryer: Redesign of heat exchangers network and components , 2017 .

[17]  Tomas Gil-Lopez,et al.  Energetic, environmental and economic analysis of climatic separation by means of air curtains in cold storage rooms , 2014 .

[18]  Emrah Alkaya,et al.  Sustainable textile production: a case study from a woven fabric manufacturing mill in Turkey , 2014 .

[19]  Francesco Montomoli,et al.  Geometrical Uncertainty and Film Cooling: Fillet Radii , 2012 .

[20]  Arif Hepbasli,et al.  Exergetic performance assessment of a stenter system in a textile finishing mill , 2007 .

[21]  Wojciech Węgrzyński,et al.  Air curtain as a barrier for smoke in case of fire: Numerical modelling , 2015 .

[22]  Gui-Bing Hong,et al.  Energy conservation potential in Taiwanese textile industry , 2010 .

[23]  Mehmet Kitis,et al.  Sustainable textile production: cleaner production assessment/eco-efficiency analysis study in a textile mill , 2016 .

[24]  Wahidul K. Biswas,et al.  A regional synergy approach to energy recovery: The case of the Kwinana industrial area, Western Australia , 2008 .

[25]  Rahman Saidur,et al.  Waste-heat utilization – The sustainable technologies to minimize energy consumption in Bangladesh textile sector , 2017 .

[26]  José J. Costa,et al.  On the use of infrared thermography in studies with air curtain devices , 2006 .

[27]  Wen Nie,et al.  Research on tunnel ventilation systems: Dust Diffusion and Pollution Behaviour by air curtains based on CFD technology and field measurement , 2019, Building and Environment.