In this paper a three-phase four-leg voltage source inverter operating in island mode is described. The four-leg inverter is implemented by using a delta/wye or ZigZag transformer to meet isolation requirement. The control scheme includes an inner current loop providing the capability of fast current limiting and outer voltage loop. Digital sliding mode control is used for the inner current loop which requires higher bandwidth. The voltage loop is implemented in synchronous frame with selected harmonics cancellation for both positive and negative sequence components. Simulation and test of a 125 kW inverter at various operation conditions are presented to verify the validity of the control method.

[1]  Paolo Mattavelli,et al.  Repetitive-Based Controller for a UPS Inverter to Compensate Unbalance and Harmonic Distortion , 2007, IEEE Transactions on Industrial Electronics.

[2]  A. Keyhani,et al.  Control of distributed generation systems-Part I: Voltages and currents control , 2004, IEEE Transactions on Power Electronics.

[3]  Dong-Seok Hyun,et al.  Advanced Synchronous Reference Frame Controller for Three-phase UPS Powering Unbalanced and Nonlinear Loads , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[4]  Atsuo Kawamura,et al.  Deadbeat controlled PWM inverter with parameter estimation using only voltage sensor , 1988, 1986 17th Annual IEEE Power Electronics Specialists Conference.

[5]  T. Undeland,et al.  Stationary frame voltage harmonic controller for standalone power generation , 2007, 2007 European Conference on Power Electronics and Applications.

[6]  F. Botteron,et al.  A Three-Phase UPS That Complies With the Standard IEC 62040-3 , 2007, IEEE Transactions on Industrial Electronics.

[7]  A. Keyhani,et al.  Optimal control of three-phase PWM inverter for UPS systems , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[8]  Ying-Yu Tzou,et al.  Sliding mode control of a closed-loop regulated PWM inverter under large load variations , 1993, Proceedings of IEEE Power Electronics Specialist Conference - PESC '93.

[9]  Jin-Woo Jung,et al.  A Three-Phase Four-Wire Inverter Control Technique for a Single Distributed Generation Unit in Island Mode , 2008, IEEE Transactions on Power Electronics.

[10]  Paolo Mattavelli,et al.  Synchronous-frame harmonic control for high-performance AC power supplies , 2001 .

[11]  Shih-Liang Jung,et al.  Discrete feedforward sliding mode control of a PWM inverter for sinusoidal output waveform synthesis , 1994, Proceedings of 1994 Power Electronics Specialist Conference - PESC'94.

[12]  G.K. Venayagamoorthy,et al.  Multiple Reference Frame-Based Control of Three-Phase PWM Boost Rectifiers under Unbalanced and Distorted Input Conditions , 2008, IEEE Transactions on Power Electronics.

[13]  Jun Liang,et al.  H ∞ repetitive control of DC-AC converters in micro-grids ∗ , 2022 .

[14]  Takao Kawabata,et al.  Digital control of three-phase PWM inverter with LC filter , 1991 .

[15]  T. Kawabata,et al.  Dead beat control of three phase PWM inverter , 1987, IEEE Power Electronics Specialists Conference.

[16]  Osman Kukrer,et al.  Deadbeat control of a three-phase inverter with an output LC filter , 1996 .

[17]  G. Weiss,et al.  H/sup /spl infin// repetitive control of DC-AC converters in microgrids , 2004, IEEE Transactions on Power Electronics.