Design of a high-precision two-dimensional coplanar micro-vibration generator

A high-precision two-dimensional (2D) coplanar micro-vibration generator with a flexure decoupling mechanism is proposed in this study. The generator is composed of a 2D symmetrical coplanar platform and a slider pair. The 2D coplanar platform structure is fully symmetric to achieve decoupling of motion in the X and Y directions. The vertical support with a slider pair is used to guarantee strict planar motion with heavy loads. Under open-loop control, the developed generator has the capability of translational motion stroke of 48.71 μm and 49.10 μm in the X and Y directions, respectively, and the maximum coupling error is approximately 0.78%. A PID control system was designed to realize the closed-loop control of the vibration generator. The control system can effectively reduce the inertial vibration and settling time of the generator. In addition, the closed-loop controlled vibration generator also has good motion tracking characteristics.

[1]  Rui-Jun Li,et al.  High-precision and low-cost vibration generator for low-frequency calibration system , 2018 .

[2]  Qingsong Xu,et al.  New Flexure Parallel-Kinematic Micropositioning System With Large Workspace , 2012, IEEE Transactions on Robotics.

[3]  Bijan Shirinzadeh,et al.  Design and Computational Optimization of a Decoupled 2-DOF Monolithic Mechanism , 2014, IEEE/ASME Transactions on Mechatronics.

[4]  Qingsong Xu,et al.  Design and Development of a Compact Flexure-Based $XY$ Precision Positioning System With Centimeter Range , 2014, IEEE Transactions on Industrial Electronics.

[5]  P. Hu,et al.  A high-precision two-dimensional micro-accelerometer for low-frequency and micro-vibrations , 2021 .

[6]  Haitong Wang,et al.  Design and analysis of a 2-degree-of-freedom flexure-based micro-motion stage , 2016 .

[7]  David M. Lally,et al.  AUTOMATED TESTING OF ACCELEROMETER TRANSVERSE SENSITIVITY , 2002 .

[8]  Qingsong Xu,et al.  Design and Analysis of a Totally Decoupled Flexure-Based XY Parallel Micromanipulator , 2009, IEEE Transactions on Robotics.

[9]  P. R. Ouyang,et al.  Design and optimization of a XY compliant mechanical displacement amplifier , 2013 .

[10]  Nicolae Lobontiu,et al.  Compliant Mechanisms: Design of Flexure Hinges , 2002 .

[11]  Yanling Tian,et al.  A novel voice coil motor-driven compliant micropositioning stage based on flexure mechanism. , 2015, The Review of scientific instruments.

[12]  Zhenguo Li,et al.  Design and Experimental Testing of an Improved Large-Range Decoupled XY Compliant Parallel Micromanipulator , 2015 .

[13]  Zhihua Liu,et al.  Short communication: Automated testing of accelerometer transversesensitivity with a flexure-based XY compliant stage , 2016 .

[14]  Nicholas A J Lieven,et al.  Proceedings of the International Modal Analysis Conference (IMAC) , 2001 .