Optimal Thermodynamic Parameters of Two-Phase Ejector Refrigeration System for Buses

Abstract Air-conditioning is necessary for the comfort of passengers in commercial buses. However, installing an air-conditioning system can add extra load on the engine and result in extra fuel cost. Therefore, an improvement in the air-conditioning system can lower the fuel consumption of the buses and reduce the size of the evaporator and the condenser. It is known that using two-phase ejector as an expansion valve in the air-conditioning system can improve the system performance. This study offers a model to predict the optimal thermodynamic parameters for a two-phase ejector refrigeration system for buses using R134a under various operating conditions. An empirical correlation is derived to determine the optimal thermodynamic parameters of the system. The effect of evaporation and condensation temperatures on the heat transfer surface area are discussed and graphically illustrated. Moreover, an experimental study to validate the developed model has been carried out in a midibus air-conditioning system. The study findings revealed that the heat transfer surface area can be reduced by about 4% and 55% in the condenser and evaporator, respectively.

[1]  Lee Kyu Hyun,et al.  Thermal Flow Analysis of HFC-134a MFC Condenser for Automotive Air-Conditioner , 1997 .

[2]  Francisco Castro,et al.  Automotive Evaporator and Condenser Modeling , 1993 .

[3]  F. Wang,et al.  Analysis for the ejector used as expansion valve in vapor compression refrigeration cycle , 2016 .

[4]  Tuncay Yilmaz,et al.  Thermodynamic analysis of the two-phase ejector air-conditioning system for buses , 2015 .

[5]  Mika Gocho,et al.  Ejector-Type Cool Box , 2008 .

[6]  Neal Lawrence,et al.  Theoretical and practical comparison of two-phase ejector refrigeration cycles including First and Second Law analysis , 2013 .

[7]  K. Gungor,et al.  A general correlation for flow boiling in tubes and annuli , 1986 .

[8]  Eric Granryd Analytical expressions for optimum flow rates in evaporators and condensers of heat pumping systems , 2010 .

[9]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[10]  Sepehr Sanaye,et al.  Modeling and multi-objective optimization of parallel flow condenser using evolutionary algorithm , 2011 .

[11]  Hirotsugu Takeuchi,et al.  World's First High Efficiency Refrigeration Cycle with Two-Phase Ejector: “EJECTOR CYCLE” , 2004 .

[12]  Şaban Ünal,et al.  Determination of the ejector dimensions of a bus air-conditioning system using analytical and numerical methods , 2015 .

[13]  F. Dittus,et al.  Heat transfer in automobile radiators of the tubular type , 1930 .

[14]  W. F. Stoecker,et al.  Refrigeration and air conditioning , 1958 .

[15]  H. Kursad Ersoy,et al.  Preliminary experimental results on the R134a refrigeration system using a two-phase ejector as an expander , 2014 .

[16]  C. Shen,et al.  Analysis of the performance of the evaporator of automotive air conditioning system , 2014 .

[17]  F. W. Yu,et al.  Improved condenser design and condenser-fan operation for air-cooled chillers , 2006 .

[18]  Jia Yan,et al.  Numerical investigation of geometry parameters for pressure recovery of an adjustable ejector in multi-evaporator refrigeration system , 2013 .

[19]  J. E. Janssen,et al.  Ventilation for acceptable indoor air quality , 1989 .

[20]  Jia Yan,et al.  Experimental investigation of the adjustable ejector in a multi-evaporator refrigeration system , 2013 .

[21]  A. London,et al.  Compact heat exchangers , 1960 .

[22]  Jahar Sarkar,et al.  Performance analyses of novel two-phase ejector enhanced multi-evaporator refrigeration systems , 2017 .

[23]  Philippe Haberschill,et al.  Investigation of a novel ejector expansion refrigeration system using the working fluid R134a and its potential substitute R1234yf , 2014 .

[24]  Neal Lawrence,et al.  Experimental investigation of a two-phase ejector cycle suitable for use with low-pressure refrigerants R134a and R1234yf , 2014 .

[25]  Alan A. Kornhauser,et al.  The Use of an Ejector as a Refrigerant Expander , 1990 .