Copper (II) adsorbed on SiO(2)/SnO(2) obtained by the sol-gel processing method: application as electrochemical sensor for ascorbic acid.

With the objective of producing a material showing better conductive properties to be used as a support for electroactive species, a SiO(2)/SnO(2) mixed oxide was prepared. The procedure for SiO(2)/SnO(2) mixed oxide preparation using the sol-gel processing method, starting from tetraethylorthosilicate and SnI(4) as precursor reagents, is described. SiO(2)/SnO(2) with composition Sn=15.6 wt% and S(BET) = 525 m(2)g(-1), V(p)=0.28 mlg(-1), and D(p)= 1.5 nm, where S(BET), V(p) and D(p) are the specific surface area, the average pore volume, and the average pore diameter, respectively, was obtained. The X-ray photoelectron spectroscopy showed that the mixed oxide was thermally very stable for samples heat-treated at up to 1073 K. The Brønsted acid sites, probed with pyridine molecules for samples heat-treated at various temperatures, were chemically stable up to 473 K. Segregation of SnO(2) crystalline phase was observed at 1473 K but no crystalline phase was verified for SiO(2) at this temperature. The porous SiO(2)/SnO(2) matrix was used as base for Cu(II) immobilization and an electrode was developed for application in electrochemical detection of vitamin C in tablets.

[1]  C. Brinker,et al.  Sol-Gel Science: The Physics and Chemistry of Sol-Gel Processing , 1990 .

[2]  Gunther A. P. Zaldivar,et al.  Structure and electrochemical property of the cobalt(II) hexacyanoferrate complex immobilized on Sn(IV) oxide coated on silica gel surface , 1994 .

[3]  A. Gonzalez-Elipe,et al.  Interface effects for metal oxide thin films deposited on another metal oxide II. SnO2 deposited on SiO2 , 1996 .

[4]  Elizabeth Fátima Perez,et al.  Bi-enzymatic amperometric biosensor for oxalate , 2001 .

[5]  F. Gan,et al.  The infrared vibration characteristics of SnO2 nanoparticles , 1999 .

[6]  C. Airoldi,et al.  The key role of copper complexes adsorbed on a chemically endcapped diamine bonded phase for HPLC , 2001 .

[7]  E. P. Parry,et al.  An infrared study of pyridine adsorbed on acidic solids. Characterization of surface acidity , 1963 .

[8]  Peter Goodhew,et al.  Electron Microscopy And Analysis , 1975 .

[9]  R. Ceccato,et al.  Structural analysis of mixed tin oxides produced by the sol-gel method , 1995 .

[10]  Iris L. Torriani,et al.  Antimony(v) oxide grafted onto a silica gel surface: acidic properties and thermal stability , 1992 .

[11]  A. Walcarius Electroanalysis with Pure, Chemically Modified and Sol-Gel-Derived Silica-Based Materials , 2001 .

[12]  Y. Gushikem,et al.  Metal Oxide Thin Films Grafted on Silica Gel Surfaces: Recent Advances on the Analytical Application of these Materials , 2001 .

[13]  Lauro T. Kubota,et al.  Electrochemical Properties of [Ru(edta)(H2O)]−Immobilized on a Zirconium(IV) Oxide-Coated Silica Gel Surface , 1996 .

[14]  Alain Walcarius,et al.  Analytical Applications of Silica-Modified Electrodes -A Comprehensive Review , 1999 .

[15]  P. Swift Adventitious carbon—the panacea for energy referencing? , 1982 .

[16]  Lambin,et al.  Characterization of tin oxides by x-ray-photoemission spectroscopy. , 1992, Physical review. B, Condensed matter.

[17]  C. Collins,et al.  Chromatographic evaluation of radiation-immobilized poly(methyloctylsiloxane) on titanium-grafted silica , 1999 .

[18]  W. Stickle,et al.  Handbook of X-Ray Photoelectron Spectroscopy , 1992 .

[19]  J. Lindquist Voltammetric determination of ascorbic acid by use of a carbon paste electrode. , 1975, The Analyst.

[20]  K. Tanabe New Solid Acids and Bases: Their Catalytic Properties , 1990 .

[21]  M. Kosec,et al.  Structural and FTIR spectroscopic studies of gel-xerogel-oxide transitions of SnO 2 and SnO 2 : Sb powders and dip-coated films prepared via inorganic sol-gel route , 1994 .

[22]  Y. Kawano,et al.  Raman and infrared spectra of silica gel and niobium(V) oxide grafted on silica gel surface and their dependence on pretreatment temperatures , 1994 .

[23]  Lauro T. Kubota,et al.  Tin(IV) oxide grafted on a silica gel surface as a conducting substrate base for cupric hexacyanoferrate , 1991 .

[24]  L. Kubota,et al.  Biosensor for phenol based on the direct electron transfer blocking of peroxidase immobilising on silica–titanium , 1999 .

[25]  L. Kubota,et al.  Electrochemical study of methylene blue immobilized in zirconium phosphate , 1997 .

[26]  L. Kubota,et al.  Electrochemical properties of iron phthalocyanine immobilized on titanium(IV) oxide coated on silica gel surface , 1995 .

[27]  K. Kawazoe,et al.  METHOD FOR THE CALCULATION OF EFFECTIVE PORE SIZE DISTRIBUTION IN MOLECULAR SIEVE CARBON , 1983 .

[28]  A. Ivaska,et al.  Voltammetric and amperometric determination of ascorbic acid at a chemically modified carbon fibre microelectrode. , 1993, Talanta.

[29]  C. Powell Attenuation lengths of low-energy electrons in solids , 1974 .

[30]  S. Fujiwara Adsorption of FeCl3, CuCl2 and ZnCl2 on silsesquioxane 3-n-propylpyridiniumchloride polymer film adsorbed on Al2O3 coated silica gel , 2001 .

[31]  J. H. Scofield,et al.  Hartree-Slater subshell photoionization cross-sections at 1254 and 1487 eV , 1976 .

[32]  K. Collins,et al.  Effects in high-performance liquid chromatography of a high pH in the mobile phase on poly(methyloctylsiloxane) immobilized by gamma-radiation on titanium-grafted silica. , 2000, Journal of chromatography. A.

[33]  L. Gorton,et al.  Preliminary electrochemical study of phenothiazines and phenoxazines immobilized on zirconium phosphate , 1997 .

[34]  C. Morterra,et al.  On the use of pyridine adsorption as an analytical tool in surface chemistry , 1990 .

[35]  Alain Walcarius,et al.  Electrochemical Applications of Silica-Based Organic−Inorganic Hybrid Materials , 2001 .