Transformers Health Index Assessment Based on Neural-Fuzzy Network

In this paper, an assessment on the health index (HI) of transformers is carried out based on Neural-Fuzzy (NF) method. In-service condition assessment data, such as dissolved gases, furans, AC breakdown voltage (ACBDV), moisture, acidity, dissipation factor (DF), color, interfacial tension (IFT), and age were fed as input parameters to the NF network. The NF network were trained individually based on two sets of data, known as in-service condition assessment and Monte Carlo Simulation (MCS) data. HI was also obtained from the scoring method for comparison with the NF method. It is found that the HI of transformers that was obtained by NF trained by MCS method is closer to scoring method than NF trained by in-service condition assessment method. Based on the total of 15 testing transformers, NF trained by MCS data method gives 10 transformers with the same assessments as scoring method as compared to eight transformers given by NF trained by in-service condition data method. Analysis based on all 73 transformers reveals that 62% of transformers have the same assessments between NF trained by MCS data and scoring methods.

[1]  Jyh-Shing Roger Jang,et al.  ANFIS: adaptive-network-based fuzzy inference system , 1993, IEEE Trans. Syst. Man Cybern..

[2]  Jashandeep Singh,et al.  Condition Monitoring of Power Transformers - Bibliography Survey , 2008, IEEE Electrical Insulation Magazine.

[3]  Debangshu Dey,et al.  Recent Trends in the Condition Monitoring of Transformers , 2013 .

[4]  K. D. Srivastava,et al.  Review of condition assessment of power transformers in service , 2002 .

[5]  M. M. A. Salama,et al.  Determination of transformer health condition using artificial neural networks , 2011, 2011 International Symposium on Innovations in Intelligent Systems and Applications.

[6]  A. de Pablo Furfural and ageing: how are they related , 1999 .

[7]  Khaled Bashir Shaban,et al.  Transformer Health Index estimation using Orthogonal Wavelet Network , 2015, 2015 IEEE Electrical Power and Energy Conference (EPEC).

[8]  Kittanut Taengko,et al.  Risk assessment for power transformers in PEA substations using health index , 2013, 2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology.

[9]  A. Abu-Siada,et al.  A review of dissolved gas analysis measurement and interpretation techniques , 2014, IEEE Electrical Insulation Magazine.

[10]  E. Gockenbach,et al.  Asset-Management of Transformers Based on Condition Monitoring and Standard Diagnosis [Feature Article] , 2008, IEEE Electrical Insulation Magazine.

[11]  Gian Carlo Montanari,et al.  Monitoring HV transformer conditions: The strength of combining various diagnostic property observations , 2014, 2014 International Conference on Advances in Communication and Computing Technologies (ICACACT 2014).

[12]  Wang Fan,et al.  An approach to power transformer asset management using health index , 2009, IEEE Electrical Insulation Magazine.

[13]  Q. H. Wu,et al.  Condition Monitoring and Assessment of Power Transformers Using Computational Intelligence , 2011 .

[14]  Balint Nemeth,et al.  Condition monitoring of power transformers using DGA and Fuzzy logic , 2009, 2009 IEEE Electrical Insulation Conference.

[15]  Rattanakorn Phadungthin,et al.  Risk optimization of power transformer tank and accessories: Practical experiences in Thailand , 2015, 2015 50th International Universities Power Engineering Conference (UPEC).

[16]  R. Piercy,et al.  An Approach to Determine the Health Index of Power Transformers , 2008, Conference Record of the 2008 IEEE International Symposium on Electrical Insulation.

[17]  M. M. A. Salama,et al.  Calculation of a Health Index for Oil-Immersed Transformers Rated Under 69 kV Using Fuzzy Logic , 2012, IEEE Transactions on Power Delivery.

[18]  S Eeckhoudt,et al.  Applicability of methanol as new marker for paper degradation in power transformers , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  Hui Ma,et al.  Application of fuzzy support vector machine for determining the health index of the insulation system of in-service power transformers , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  Miroslav Uher,et al.  Application of the Monte Carlo method to estimate the uncertainty of air flow measurement , 2015, Proceedings of the 2015 16th International Carpathian Control Conference (ICCC).

[21]  A. Abu-Siada,et al.  A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysis , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  Nadrae T. Waugh,et al.  Improving the life cycle management of power transformers transforming data to life , 2015, SoutheastCon 2015.

[23]  Rattanakorn Phadungthin,et al.  Condition assessment of the health index for power transformer , 2012, 2012 Power Engineering and Automation Conference.