Validation of quantitative attenuation and backscattering coefficient measurements by optical coherence tomography in the concentration-dependent and multiple scattering regime

Abstract. Optical coherence tomography (OCT) has the potential to quantitatively measure optical properties of tissue such as the attenuation coefficient and backscattering coefficient. However, to obtain reliable values for strong scattering tissues, accurate consideration of the effects of multiple scattering and the nonlinear relation between the scattering coefficient and scatterer concentration (concentration-dependent scattering) is required. We present a comprehensive model for the OCT signal in which we quantitatively account for both effects, as well as our system parameters (confocal point spread function and sensitivity roll-off). We verify our model with experimental data from controlled phantoms of monodisperse silica beads (scattering coefficients between 1 and 30  mm−1 and scattering anisotropy between 0.4 and 0.9). The optical properties of the phantoms are calculated using Mie theory combined with the Percus–Yevick structure factor to account for concentration-dependent scattering. We demonstrate excellent agreement between the OCT attenuation and backscattering coefficient predicted by our model and experimentally derived values. We conclude that this model enables us to accurately model OCT-derived parameters (i.e., attenuation and backscattering coefficients) in the concentration-dependent and multiple scattering regime for spherical monodisperse samples.

[1]  Chenyang Xu,et al.  Characterization of atherosclerosis plaques by measuring both backscattering and attenuation coefficients in optical coherence tomography. , 2008, Journal of biomedical optics.

[2]  Michel Verhaegen,et al.  Towards model-based adaptive optics optical coherence tomography. , 2014, Optics express.

[3]  Jerome K. Percus,et al.  Analysis of Classical Statistical Mechanics by Means of Collective Coordinates , 1958 .

[4]  Joseph M. Schmitt,et al.  MODEL OF OPTICAL COHERENCE TOMOGRAPHY OF HETEROGENEOUS TISSUE , 1997 .

[5]  A. P. Shepherd,et al.  Comparison of Mie theory and the light scattering of red blood cells. , 1988, Applied optics.

[6]  A. Amelink,et al.  Measurement of tissue scattering properties using multi-diameter single fiber reflectance spectroscopy: in silico sensitivity analysis , 2011, Biomedical optics express.

[7]  Tianheng Wang,et al.  Optical scattering coefficient estimated by optical coherence tomography correlates with collagen content in ovarian tissue. , 2011, Journal of biomedical optics.

[8]  David D Sampson,et al.  Correlation of static speckle with sample properties in optical coherence tomography. , 2006, Optics letters.

[9]  Ton G van Leeuwen,et al.  Volumetric in vivo visualization of upper urinary tract tumors using optical coherence tomography: a pilot study. , 2013, The Journal of urology.

[10]  C. Tropea,et al.  Light Scattering from Small Particles , 2003 .

[11]  Ton G van Leeuwen,et al.  Measurements of wavelength dependent scattering and backscattering coefficients by low-coherence spectroscopy. , 2011, Journal of biomedical optics.

[12]  Yingtian Pan,et al.  Detection of tumorigenesis in urinary bladder with optical coherence tomography: optical characterization of morphological changes. , 2002, Optics express.

[13]  S. Yun,et al.  In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve. , 2004, Optics express.

[14]  Hessel Wijkstra,et al.  Advanced diagnostics in renal mass using optical coherence tomography: a preliminary report. , 2011, Journal of endourology.

[15]  David Levitz,et al.  Quantitative characterization of developing collagen gels using optical coherence tomography. , 2010, Journal of biomedical optics.

[16]  J. Kong,et al.  Scattering of Electromagnetic Waves, Numerical Simulations , 2001 .

[17]  Theo J M Ruers,et al.  Optical coherence tomography in vulvar intraepithelial neoplasia , 2012, Journal of biomedical optics.

[18]  Dudley A. Williams,et al.  Optical properties of water in the near infrared. , 1974 .

[19]  Dirk J. Faber,et al.  A literature review and novel theoretical approach on the optical properties of whole blood , 2013, Lasers in Medical Science.

[20]  Dirk J. Faber,et al.  Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography. , 2005 .

[21]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[22]  Gurdev Singh,et al.  Influence of sodium dodecyl sulfate on colloidal fouling potential during ultrafiltration , 2006 .

[23]  H. Yura,et al.  Analysis of optical coherence tomography systems based on the extended Huygens-Fresnel principle. , 2000, Journal of the Optical Society of America. A, Optics, image science, and vision.

[24]  D. Faber,et al.  Functional optical coherence tomography of pigmented lesions , 2015, Journal of the European Academy of Dermatology and Venereology : JEADV.

[25]  I. Malitson Interspecimen Comparison of the Refractive Index of Fused Silica , 1965 .

[26]  Dirk J. Faber,et al.  Measurement of the axial point spread function in scattering media using single-mode fiber-based optical coherence tomography , 2003 .

[27]  T G van Leeuwen,et al.  Dependent and multiple scattering in transmission and backscattering optical coherence tomography. , 2013, Optics express.

[28]  J van Marle,et al.  Determination of the scattering anisotropy with optical coherence tomography. , 2011, Optics express.

[29]  Gijs van Soest,et al.  Atherosclerotic tissue characterization in vivo by optical coherence tomography attenuation imaging. , 2010, Journal of biomedical optics.

[30]  Ton G van Leeuwen,et al.  Are quantitative attenuation measurements of blood by optical coherence tomography feasible? , 2009, Optics letters.

[31]  Ton G van Leeuwen,et al.  Quantitative measurement of attenuation coefficients of bladder biopsies using optical coherence tomography for grading urothelial carcinoma of the bladder. , 2010, Journal of biomedical optics.

[32]  D. Sampson,et al.  Parametric imaging of cancer with optical coherence tomography. , 2010, Journal of biomedical optics.

[33]  H. Lemij,et al.  Depth-resolved model-based reconstruction of attenuation coefficients in optical coherence tomography. , 2013, Biomedical optics express.

[34]  Teresa C. Chen,et al.  Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography. , 2004, Optics express.

[35]  Theo J M Ruers,et al.  Learning curve and interobserver variance in quantification of the optical coherence tomography attenuation coefficient , 2015, Journal of biomedical optics.

[36]  Steven L. Jacques,et al.  Measuring tissue optical properties in vivo using reflectance-mode confocal microscopy and OCT , 2008, SPIE BiOS.

[37]  G. M. Hale,et al.  Optical Constants of Water in the 200-nm to 200-microm Wavelength Region. , 1973, Applied optics.

[38]  Dirk Faber,et al.  Functional optical coherence tomography : spatially resolved measurements of optical properties , 2005 .

[39]  J. Schmitt,et al.  Optical scattering properties of soft tissue: a discrete particle model. , 1998, Applied optics.

[40]  Jaap R. Zijp,et al.  Pascal program to perform Mie calculations , 1993 .

[41]  J M Schmitt,et al.  Turbulent nature of refractive-index variations in biological tissue. , 1996, Optics letters.

[42]  D. Sampson,et al.  Parametric imaging of the local attenuation coefficient in human axillary lymph nodes assessed using optical coherence tomography , 2012, Biomedical optics express.