Anatomical background noise power spectrum in differential phase contrast breast images

In x-ray breast imaging, the anatomical noise background of the breast has a significant impact on the detection of lesions and other features of interest. This anatomical noise is typically characterized by a parameter, β, which describes a power law dependence of anatomical noise on spatial frequency (the shape of the anatomical noise power spectrum). Large values of β have been shown to reduce human detection performance, and in conventional mammography typical values of β are around 3.2. Recently, x-ray differential phase contrast (DPC) and the associated dark field imaging methods have received considerable attention as possible supplements to absorption imaging for breast cancer diagnosis. However, the impact of these additional contrast mechanisms on lesion detection is not yet well understood. In order to better understand the utility of these new methods, we measured the β indices for absorption, DPC, and dark field images in 15 cadaver breast specimens using a benchtop DPC imaging system. We found that the measured β value for absorption was consistent with the literature for mammographic acquisitions (β = 3.61±0.49), but that both DPC and dark field images had much lower values of β (β = 2.54±0.75 for DPC and β = 1.44±0.49 for dark field). In addition, visual inspection showed greatly reduced anatomical background in both DPC and dark field images. These promising results suggest that DPC and dark field imaging may help provide improved lesion detection in breast imaging, particularly for those patients with dense breasts, in whom anatomical noise is a major limiting factor in identifying malignancies.

[1]  Srinivasan Vedantham,et al.  Scaling-law for the energy dependence of anatomic power spectrum in dedicated breast CT. , 2013, Medical physics.

[2]  John M Boone,et al.  Characterizing anatomical variability in breast CT images. , 2008, Medical physics.

[3]  Ke Li,et al.  Grating based x-ray differential phase contrast imaging without mechanical phase stepping. , 2014, Optics express.

[4]  Anita Nosratieh,et al.  Anatomical complexity in breast parenchyma and its implications for optimal breast imaging strategies. , 2012, Medical physics.

[5]  Francis R. Verdun,et al.  Importance of anatomical noise in mammography , 1997, Medical Imaging.

[6]  J. Boone,et al.  Association between power law coefficients of the anatomical noise power spectrum and lesion detectability in breast imaging modalities. , 2013, Physics in medicine and biology.

[7]  J. H. van Hateren,et al.  Modelling the Power Spectra of Natural Images: Statistics and Information , 1996, Vision Research.

[8]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[9]  A. Burgess,et al.  Human observer detection experiments with mammograms and power-law noise. , 2001, Medical physics.

[10]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[11]  F R Verdun,et al.  Estimation of the noisy component of anatomical backgrounds. , 1999, Medical physics.

[12]  M. Yaffe,et al.  Characterisation of mammographic parenchymal pattern by fractal dimension. , 1990, Physics in medicine and biology.