Accuracy and conformity of stereotactically guided interstitial brain tumour therapy using I-125 seeds.

OBJECTIVE To assess the accuracy of the stereotactic implantation procedure of catheters containing I-125 seeds in brain tumours and investigate the effect of catheter deviations on the dose distribution in patients. METHODS A randomised sample (n = 37) of all patients treated with I-125 seeds in our department between 6/1994 and 2/2002 was examined. Intraoperative X-ray images were used to measure deviations of implanted I-125 seed catheters from their planned positions and the influence on dose conformity, tumour surface dose and dose burden of surrounding healthy brain tissue was determined. RESULTS The mean spatial target point deviation was 2.0 mm (maximum 4.1 mm, SD 0.9 mm) and in 54.1% of the cases, reduction of the planned dose was greater than 5%. Target point deviations less than 1.5 mm have only minor influence on surface dose and conformity. Results indicated that in 10.8% of the cases the realized dose distribution showed a 'slight deviation', according to the guideline criteria for external radiosurgery of the Radiation Therapy Oncology Group. In 89.2% of the patients the applied dose conformed to the target volume. CONCLUSIONS Stereotactically guided interstitial irradiation with I-125 seeds can be used to treat brain tumours and metastases with high conformity comparable to radiosurgery. The observed deviations of the stereotactically implanted I-125 seed catheters from their planned target points were smaller when compared to frameless procedures. In order to maintain the required spatial accuracy of 1.5 mm in interstitial therapy using I-125 seeds, it appears necessary to optimise stereotactic instruments further.

[1]  L Souhami,et al.  Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines. , 1993, International journal of radiation oncology, biology, physics.

[2]  S Hunsche,et al.  MR-guided stereotactic neurosurgery--comparison of fiducial-based and anatomical landmark transformation approaches. , 2004, Physics in medicine and biology.

[3]  R. Hassler,et al.  Anatomische Treffsicherheit der stereotaktischen Parkinson-Operationen auf Grund autoptischer Bestimmung , 1969, European Archives of Psychiatry and Neurological Sciences.

[4]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[5]  M Hoevels,et al.  The influence of head frame distortions on stereotactic localization and targeting. , 2004, Physics in medicine and biology.

[6]  M. Faist,et al.  The risk of interstitial radiotherapy of low-grade gliomas. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  M. Malkin,et al.  The relationship between the technical accuracy of stereotactic interstitial implantation for high grade gliomas and the pattern of tumor recurrence. , 1995, International journal of radiation oncology, biology, physics.

[8]  K Herholz,et al.  Correlation of glucose consumption and tumor cell density in astrocytomas. A stereotactic PET study. , 1993, Journal of neurosurgery.

[9]  K Herholz,et al.  Three-dimensional alignment of functional and morphological tomograms. , 1990, Journal of computer assisted tomography.

[10]  R P Müller,et al.  On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers. , 2000, Physics in medicine and biology.

[11]  David G. T. Thomas,et al.  Stereotactic And Image Directed Surgery of Brain Tumours , 1993 .

[12]  L. Schad,et al.  Three dimensional image correlation of CT, MR, and PET studies in radiotherapy treatment planning of brain tumors. , 1987, Journal of computer assisted tomography.

[13]  W Schlegel,et al.  Computerized optimization of 125I implants in brain tumors. , 1988, International journal of radiation oncology, biology, physics.

[14]  E Kanal,et al.  A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. , 1992, Neurosurgery.

[15]  W Schlegel,et al.  Photogrammetric accuracy measurements of head holder systems used for fractionated radiotherapy. , 1994, International journal of radiation oncology, biology, physics.

[16]  Interstitial irradiation with stereotactically implanted I-125 seeds for the treatment of cerebral glioma , 1999, Critical reviews in neurosurgery : CR.

[17]  H. Nishimatsu,et al.  The effects of intraoperative radiotherapy on bone-healing ability in relation to different doses and postradiotherapy intervals. , 1994, International journal of radiation oncology, biology, physics.

[18]  R Boesecke,et al.  Optimization and evaluation of landmark-based image correlation. , 1992, Physics in medicine and biology.

[19]  Steven D Chang,et al.  An Analysis of the Accuracy of the CyberKnife: A Robotic Frameless Stereotactic Radiosurgical System , 2003, Neurosurgery.

[20]  O. Pastyr,et al.  Stereotactic computer tomography with a modified Riechert-Mundinger device as the basis for integrated stereotactic neuroradiological investigations , 2005, Acta Neurochirurgica.

[21]  M van Herk,et al.  Magnetic resonance image-directed stereotactic neurosurgery: use of image fusion with computerized tomography to enhance spatial accuracy. , 1995, Journal of neurosurgery.

[22]  R. Maciunas,et al.  Effect of Changing Patient Position from Supine to Prone on the Accuracy of a Brown-Roberts-Wells Stereotactic Head Frame System , 2003, Neurosurgery.

[23]  R. Müller,et al.  Risk analysis of linear accelerator radiosurgery. , 1996, International journal of radiation oncology, biology, physics.

[24]  W Schlegel,et al.  Display of organs and isodoses as shaded 3-D objects for 3-D therapy planning. , 1987, International journal of radiation oncology, biology, physics.

[25]  C. Yu,et al.  A Phantom Study of the Geometric Accuracy of Computed Tomographic and Magnetic Resonance Imaging Stereotactic Localization with the Leksell Stereotactic System , 2001, Neurosurgery.

[26]  Georg Schmitz,et al.  A Gaussian approach for the calculation of the accuracy of stereotactic frame systems , 1999 .

[27]  Berndt Wowra,et al.  Quality assurance in stereotactic space. A system test for verifying the accuracy of aim in radiosurgery. , 2002, Medical physics.

[28]  L. Anderson,et al.  Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43 , 1995 .

[29]  D. Thomas,et al.  Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note. , 1999, Journal of neurosurgery.

[30]  R L Siddon,et al.  Stereotaxic localization of intracranial targets. , 1987, International journal of radiation oncology, biology, physics.

[31]  Computer simulation for the stereotactic placement of interstitial radionuclide sources into computed tomography-defined tumor volumes. , 1984, Neurosurgery.

[32]  L. Zamorano,et al.  Transposition of image-defined trajectories into arc-quadrant centered stereotactic systems. , 1989, Acta neurochirurgica. Supplementum.

[33]  R. Maciunas,et al.  The application accuracy of stereotactic frames. , 1994, Neurosurgery.