Modeling evaluation of integrated strategies to meet proposed dissolved oxygen standards for the Chicago waterway system.

The Chicago Waterway System (CWS) is a 113.8 km branching network of navigable waterways controlled by hydraulic structures in which the majority of flow is treated sewage effluent and there are periods of substantial combined sewer overflow. The Illinois Pollution Control Board (IPCB) designated the majority of the CWS as Secondary Contact and Indigenous Aquatic Life Use waters in the 1970s and made small alterations to these designations in 1988. Between 1988 and 2002 substantial improvements in the pollution control and water-quality management facilities were made in the Chicago area. The results of a Use Attainability Analysis led the Illinois Environmental Protection Agency (IEPA) to propose the division of the CWS into two new aquatic life use classes with appropriate dissolved oxygen (DO) standards. To aid the IPCB in their deliberations regarding the appropriate water use classifications and DO standards for the CWS, the DUFLOW model that is capable of simulating hydraulics and water-quality processes under unsteady-flow conditions was used to evaluate integrated strategies of water-quality improvement facilities that could meet the proposed DO standards during representative wet (2001) and dry (2003) years. A total of 28 new supplementary aeration stations with a maximum DO load of 80 or 100 g/s and aerated flow transfers at three locations in the CWS would be needed to achieve the IEPA proposed DO standards 100% of the time for both years. A much simpler and less costly (≈one tenth of the cost) system of facilities would be needed to meet the IEPA proposed DO standards 90% of the time. In theory, the combinations of flow augmentation and new supplemental aeration stations can achieve 100% compliance with the IEPA proposed DO standards, however, 100% compliance will be hard to achieve in practice because of-(1) difficulties in determining when to turn on the aeration stations and (2) localized heavy loads of pollutants during storms that may yield violations of the DO standards even with an extensive network of supplemental aeration stations. Thus, because absolute DO standards that must be met 100% of the time will be difficult, if not impossible to comply with, DO standards that include a Wet Weather Limited Use (WWLU) designation based on rainfall amount triggering CSO events and a maximum duration that the WWLU could be applied should be considered to obtain a healthy ecosystem by applying water-quality improvement features that can be practically operated and maintained. Such a WWLU approach also was evaluated in this paper.

[1]  Charles S Melching,et al.  Allocation of supplementary aeration stations in the Chicago waterway system for dissolved oxygen improvement. , 2011, Journal of environmental management.

[2]  Tim A. Wool,et al.  WASP4, a hydrodynamic and water-quality model - model theory, user's manual, and programmer's guide , 1988 .

[3]  K. Ahn,et al.  Application of QUAL2Kw for water quality modeling and dissolved oxygen control in the river Bagmati , 2007, Environmental monitoring and assessment.

[4]  Rodolfo Soncini-Sessa,et al.  Optimal Allocation of Artificial Instream Aeration , 1978 .

[5]  A. Soldati,et al.  Water quality control in the river Arno. , 2002, Water research.

[6]  James J. Fitzpatrick,et al.  Chesapeake Bay Sediment Flux Model , 1993 .

[7]  Robert V. Thomann,et al.  Systems analysis and water quality management , 1972 .

[8]  Poul Harremoës,et al.  Impact of rain runoff on oxygen in an urban river , 1996 .

[9]  D. Breitburg Effects of hypoxia, and the balance between hypoxia and enrichment, on coastal fishes and fisheries , 2002 .

[10]  Prateek Sharma,et al.  Water quality modelling of the river Yamuna (India) using QUAL2E-UNCAS. , 2007, Journal of environmental management.

[11]  Shaw L. Yu,et al.  Instream Aerators for Polluted Rivers , 1970 .

[12]  Georges Vachaud,et al.  Experimental investigation and modelling approach of the impact of urban wastewater on a tropical river; a case study of the Nhue River, Hanoi, Viet Nam , 2007 .

[13]  Charles S. Melching,et al.  Flow Augmentation for Dissolved Oxygen Improvement in Chicago Waterways , 2009 .

[14]  P. Bedient,et al.  Stream Dissolved Oxygen Analysis and Control , 1985 .