Quantitative high contrast X-ray microtomography for dental research.

OBJECTIVES X-ray microtomography (XMT or micro-CT) is a miniaturized version of medical CT and has been used extensively for in vitro dental research. The technique allows three-dimensional analyses of both structure and density (or concentration), the latter requiring some a priori knowledge of composition. The aim of this paper is to demonstrate the capabilities of an XMT scanner specifically designed for dental research, especially that requiring high contrast resolution or accurate mineral concentration quantification. METHODS The MuCAT scanners designed at Queen Mary, University of London, use high dynamic range CCD cameras with time-delay integration readout to provide high quality tomographic images. Accuracy in mineral concentration quantification is achieved using a modelling approach to beam hardening correction with automatic calibration following every scan. Accuracy was tested by measuring the density of a hydroxyapatite disc, and the utility of the high contrast and high accuracy capabilities are demonstrated in three applications from ongoing dental research projects. RESULTS Quantification accuracy in the hydroxyapatite disc density was better than 1%. In dental applications, slight differences in mineral concentration allowed features such as dead tracts to be visualized and ion transport from a glass-ionomer cement into demineralized dentine to be observed. CONCLUSION The improved accuracy and contrast sensitivity, together with the non-destructive nature of XMT in general, facilitates precise studies of dynamic processes in teeth. The ability to differentiate subtle differences in mineral concentration allows dead tracts to be traced in three dimensions, linking external pathology in teeth to reactive processes from the pulp. CLINICAL SIGNIFICANCE The MuCAT scanners have been optimized for quantification of mineral concentration and are particularly useful for in vitro studies of de- and re-mineralization, excavation and other treatment methodologies, and for gaining further insight into tooth morphology and pathology. Results from such studies will inform development of clinical treatment and management.

[1]  R. Fajardo,et al.  Further improvements on the factors affecting bone mineral density measured by quantitative micro-computed tomography. , 2012, Bone.

[2]  Philip M Evans,et al.  Calculation of x-ray spectra emerging from an x-ray tube. Part I. electron penetration characteristics in x-ray targets. , 2007, Medical physics.

[3]  S. Leal,et al.  Validity of MicroCT for in vitro detection of proximal carious lesions in primary molars. , 2012, Journal of dentistry.

[4]  Ralph Müller,et al.  Quantitative micro-computed tomography: a non-invasive method to assess equivalent bone mineral density. , 2008, Bone.

[5]  Graham R. Davis,et al.  High definition X-ray microtomography using a conventional impact X-ray source , 2003 .

[6]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[7]  R. Brooks,et al.  Beam hardening in X-ray reconstructive tomography , 1976 .

[8]  Graham R. Davis,et al.  A modelling approach to beam hardening correction , 2008, Optical Engineering + Applications.

[9]  K. Kunzelmann,et al.  Mineral concentration of natural human teeth by a commercial micro-CT. , 2006, Dental materials journal.

[10]  J. C. Elliott,et al.  X‐ray microtomography , 1982, Journal of microscopy.

[11]  David Mills,et al.  Quantitative x-ray microtomography with a conventional source , 2010, Optical Engineering + Applications.

[12]  Bart Van Meerbeek,et al.  Micro-CT based quantitative evaluation of caries excavation. , 2010, Dental materials : official publication of the Academy of Dental Materials.

[13]  Glen L Niebur,et al.  Improved accuracy of cortical bone mineralization measured by polychromatic microcomputed tomography using a novel high mineral density composite calibration phantom. , 2010, Medical physics.

[14]  Bart Van Meerbeek,et al.  Does DIAGNOdent provide a reliable caries-removal endpoint? , 2011, Journal of dentistry.

[15]  R. Drew,et al.  Wettability and spreading kinetics of molten aluminum on copper-coated ceramics , 2006 .

[16]  David Mills,et al.  Multi-species beam hardening calibration device for x-ray microtomography , 2012, Optics & Photonics - Optical Engineering + Applications.

[17]  Ulrich Bonse,et al.  Developments in X-Ray Tomography V , 1999 .

[18]  G. Poludniowski Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets. , 2007, Medical physics.

[19]  Ilkan Tatar,et al.  Occlusal Caries Depth Measurements Obtained by Five Different Imaging Modalities , 2011, Journal of Digital Imaging.

[20]  S. Majumdar,et al.  Quantitative Assessment of Bone Tissue Mineralization with Polychromatic Micro-Computed Tomography , 2008, Calcified Tissue International.

[21]  F. Wong,et al.  X-ray microtomography of bones and teeth. , 1996, Physiological measurement.

[22]  B. Van Meerbeek,et al.  Caries-removal effectiveness and minimal-invasiveness potential of caries-excavation techniques: a micro-CT investigation. , 2011, Journal of dentistry.

[23]  Neil Hunter,et al.  Characterization of a novel calibration method for mineral density determination of dentine by X-ray micro-tomography. , 2009, The Analyst.

[24]  J. Kirkham,et al.  Morphology and elemental composition of subgingival calculus in two ethnic groups. , 2000, Journal of periodontology.

[25]  J. H. Hubbell,et al.  XCOM: Photon Cross Section Database (version 1.2) , 1999 .

[26]  Julian D Satterthwaite,et al.  An automated assessment algorithm for micro-CT images of occlusal caries. , 2010, The surgeon : journal of the Royal Colleges of Surgeons of Edinburgh and Ireland.

[27]  F. Wong,et al.  X-Ray Microtomography Study to Validate the Efficacies of Caries Removal in Primary Molars by Hand Excavation and Chemo-Mechanical Technique , 2012, Caries Research.

[28]  Hideki Aoki,et al.  Mechanical properties of sintered hydroxyapatite for prosthetic applications , 1981 .

[29]  Graham R. Davis,et al.  X-ray microtomography scanner using time-delay integration for elimination of ring artefacts in the reconstructed image , 1997 .

[30]  Graham R. Davis Image quality in x-ray microtomography , 1997, Optics & Photonics.

[31]  J. Frencken The ART approach using glass-ionomers in relation to global oral health care. , 2010, Dental materials : official publication of the Academy of Dental Materials.

[32]  J H Koolstra,et al.  Accuracy of microCT in the quantitative determination of the degree and distribution of mineralization in developing bone , 2006, Acta radiologica.

[33]  J. Frencken,et al.  Atraumatic restorative treatment (ART): rationale, technique, and development. , 1996, Journal of public health dentistry.