Optimization of the Refractive Index of a Gap Material Used for the 4-layer DOI Detector

We have developed a 4-layer depth-of-interaction (DOI) detector which consists of four layers of scintillation crystal arrays and a position sensitive photomultiplier tube (PS-PMT). To control the behavior of scintillation light in each DOI crystal array, some reflectors between crystals are removed so that all crystal responses in the four layers are expressed in one two-dimensional (2D) position histogram by implementing an Anger-type calculation of the PS-PMT signals. Since the method utilizes spread of scintillation light through the boundary of the crystals with no reflectors, positioning performance in the 2D position histogram depends on the crystal dimensions, the crystal surface finish, and gap materials. In this work, we propose an adjustment method for crystal identification performance of the 4-layer DOI detector by selecting the optimal refractive index for the gap materials between the crystals in which the reflectors are removed. We fabricated single-layer detectors and 4-layer detectors using LYSO scintillators and evaluated the crystal identification performance, while varying the refractive index of the gap materials (by using different optical cements). As a result, we found the 2D position histogram changes as a function of the refractive index of the optical cement between crystals and the optimal refractive indices can be determined for the detector using the LYSO crystals. We concluded that the crystal response of the 2D position histograms can be adjusted and crystal identification performance can be optimized by changing the refractive index of the gap materials.

[1]  H. Kawai,et al.  Development of a four-layer DOI detector composed of Zr-doped GSO scintillators and a high sensitive multi-anode PMT , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[2]  R. Yamada,et al.  Development of a high-resolution four-layer DOI detector using MPPCs for brain PET , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[3]  M. Horowitz,et al.  Analog signal multiplexing for PSAPD-based PET detectors: simulation and experimental validation , 2010, Physics in medicine and biology.

[4]  Keishi Kitamura,et al.  Spatial resolution evaluation with a pair of two four-layer DOI detectors for small animal PET scanner: jPET-RD , 2008 .

[5]  Hideaki Haneishi,et al.  Simplified simulation of four-layer depth of interaction detector for PET , 2008, Radiological physics and technology.

[6]  Yiping Shao,et al.  Initial experimental studies of using solid-state photomultiplier for PET applications , 2007 .

[7]  Fabio Morsani,et al.  The Silicon Photomultiplier for application to high-resolution Positron Emission Tomography , 2007 .

[8]  Gerald Entine,et al.  Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes , 2006, Physics in medicine and biology.

[9]  H. Murayama,et al.  A four-layer depth of interaction detector block for small animal PET , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[10]  Huafeng Liu,et al.  Development of a depth of interaction detector for γ-rays , 2001 .

[11]  Michael V. Green,et al.  Depth identification accuracy of a three layer phoswich PET detector module , 1999 .

[12]  L. MacDonald,et al.  A YSO/LSO phoswich array detector for single and coincidence photon imaging , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.