Imaging and spectral performance of CdTe double-sided strip detectors for the hard x-ray imager onboard ASTRO-H

The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm × 3.2 cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of -20°C and with an applied bias voltage of 250 V. By using two-strip events as well as one-strip events for the event reconstruction, a good energy resolution of 2.0 keV at 59.5 keV and a sub-strip spatial resolution was achieved. The hard X-ray and gamma-ray response of CdTe-DSDs is complex due to the properties of CdTe and the small pixel effect. Therefore, one of the issues to investigate is the response of the CdTe-DSD. In order to investigate the spatial dependence of the detector response, we performed fine beam scan experiments at SPring-8, a synchrotron radiation facility. From these experiments, the depth structure of the electric field was determined as well as properties of carriers in the detector and successfully reproduced the experimental data with simulated spectra.

[1]  P. Siffert,et al.  Modelling and 3D optimisation of CdTe pixels detector array geometry – Extension to small pixels , 2001 .

[2]  Tadayui Takahashi,et al.  Recent progress in CdTe and CdZnTe detectors , 2001, astro-ph/0107398.

[3]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[4]  Akira Higa,et al.  Formation of Aluminum Schottky Contact on Plasma-Treated Cadmium Telluride Surface , 2004 .

[5]  Tadayuki Takahashi,et al.  The Hard X-ray Imager (HXI) for the ASTRO-H Mission , 2014, Astronomical Telescopes and Instrumentation.

[6]  Yoshiharu Namba,et al.  The ASTRO-H Mission , 2009, Astronomical Telescopes + Instrumentation.

[7]  Zhong He,et al.  Review of the Shockley–Ramo theorem and its application in semiconductor gamma-ray detectors , 2001 .

[8]  Matts Roos,et al.  MINUIT-a system for function minimization and analysis of the parameter errors and correlations , 1984 .

[9]  Yasushi Fukazawa,et al.  Development of an integrated response generator for Si/CdTe semiconductor Compton cameras , 2010 .

[10]  Yasushi Fukazawa,et al.  Development of semiconductor imaging detectors for a Si/CdTe Compton camera , 2007 .

[11]  Kazuyuki Satoh,et al.  Growth and characterization of CdTe single crystals for radiation detectors , 1999 .

[12]  Hirokazu Odaka,et al.  New CdTe Pixel Gamma-Ray Detector with Pixelated Al Schottky Anodes , 2007 .

[13]  Kunishiro Mori,et al.  Performance of a new Schottky CdTe detector for hard X-ray spectroscopy , 1997 .

[14]  H. B. Barber,et al.  Signals induced in semiconductor gamma-ray imaging detectors , 1999 .

[15]  Motohide Kokubun,et al.  Development of Double-Sided CdTe Strip Detectors for γ-Ray Imaging and Spectroscopy , 2010 .

[16]  O. Limousin,et al.  Caliste 64, an Innovative CdTe Hard X-Ray Micro-Camera , 2008, IEEE Transactions on Nuclear Science.

[17]  T. Takahashi,et al.  High Energy Resolution Hard X-Ray and Gamma-Ray Imagers Using CdTe Diode Devices , 2009, IEEE Transactions on Nuclear Science.

[18]  K. Umetani,et al.  Construction and commissioning of a 215-m-long beamline at SPring-8 , 2001 .

[19]  Nicolas Produit,et al.  The INTEGRAL mission , 2003 .

[20]  Akira Higa,et al.  Effect of He Plasma Treatment on the Rectification Properties of Al/CdTe Schottky Contacts , 2005 .

[21]  T. Takahashi,et al.  Performance of double-sided CdTe strip detectors for gamma-ray imaging and spectroscopy , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[22]  Kazuyuki Hirose,et al.  High-resolution Schottky CdTe diode for hard X-ray and gamma-ray astronomy , 1999 .

[23]  Ryuichi Fujimoto,et al.  The X-Ray Observatory Suzaku , 2007 .