Evaluation of a Direct Lightning Strike to the 24 kV Distribution Lines in Thailand

This paper evaluates the effect of a lightning strike directly on the 24 kV distribution lines in Thailand, where such strikes are one of the main causes of power outages. The voltage across the insulator, and the arrester energy absorbed due to the lightning, need to be analyzed for different grounding distances of the overhead ground wire, ground resistance, lightning impact positions, and lightning current waveforms. Analysis and simulations are conducted using the Alternative Transients Program/Electromagnetic Transients Program (ATP/EMTP) to find the energy absorbed by the arrester and the voltages across the insulator. The results indicate that when surge arresters are not installed, the voltage across the insulator at the end of the line is approximately 1.4 times that in the middle of the line. In addition, the ground resistance and grounding distance of the overhead ground wire affect the voltage across the insulator if the overhead ground wire is struck. When surge arresters are installed, a shorter grounding distance of the overhead ground wire and a lower ground resistance are not always desirable; this is because they reduce the back-flashover rate and the voltage across the insulator if lightning strikes the overhead ground wire. However, lightning strikes to the phase conductor result in high arrester energy and the possibility that the arrester will fail. Furthermore, the tail time of the lightning waveform is a significant variable when considering the energy absorbed by the arrester, whereas the front time is important for the voltage across the insulator. In case lightning strikes directly on the connected point between the overhead lines and the underground cables, the distribution line system is protected only by the lightning arrester at the connection point. The overvoltage at the connection point is lower than the basic impulse level at 24 kV of 125 kV, but the overvoltage at the end of the cable is still more than 125 kV in case the cable is longer than 400 m. When the distribution line system is protected by the lightning arrester at both the connection point and the end of the cable, it results in overvoltage throughout the cable is lower than the critical flashover of insulation. This method is the best way to reduce the failure rate of underground cables and equipment that are connected to the distribution line system.

[1]  Rong Zeng,et al.  Statistical Analysis on Lightning Performance of Transmission Lines in Several Regions of China , 2015, IEEE Transactions on Power Delivery.

[2]  Wei Guo,et al.  Research and application of jet stream arc-quenching lightning protection gap (JSALPG) for transmission lines , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  Celio Fonseca Barbosa,et al.  Indirect Lightning Performance of Aerial Distribution Lines Considering the Induced-Voltage Waveform , 2015, IEEE Transactions on Electromagnetic Compatibility.

[4]  Atthapol Ngaopitakkul,et al.  Relation of Influential Parameters to Back-Flashover on the Insulators in Transmission Tower , 2015 .

[5]  Silverio Visacro,et al.  Lightning Performance of Transmission Lines: Methodology to Design Grounding Electrodes to Ensure an Expected Outage Rate , 2015, IEEE Transactions on Power Delivery.

[6]  P. N. Mikropoulos,et al.  Estimation of the shielding performance of overhead transmission lines: The effects of lightning attachment model and lightning crest current distribution , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[8]  A. Ametani,et al.  A method of a lightning surge analysis recommended in Japan using EMTP , 2005, IEEE Transactions on Power Delivery.

[9]  Matti Lehtonen,et al.  Mitigation of Lightning Flashover from Tree to Medium Voltage Aerial Cable Using Shield Wire , 2017, IEEE Transactions on Power Delivery.

[10]  N. Nagaoka,et al.  An Empirical Formula for the Surge Impedance of a Grounding Conductor along a Reinforced Concrete Pole in a Distribution Line , 2001 .

[11]  A. M. Gole,et al.  Modeling Guidelines for Switching Transients Report Prepared by the Switching Transients Task Force of the IEEE Modeling and Analysis of System Transients Working Group , 1998 .

[12]  Akira Asakawa,et al.  Energy absorption of surge arresters on power distribution lines due to direct lightning strokes-effects of an overhead ground wire and installation position of surge arresters , 1997 .

[13]  Jinliang He,et al.  Lightning impulse performances of grounding devices covered with low-resistivity materials , 2006, IEEE Transactions on Power Delivery.

[14]  Rolf Witzmann,et al.  Lightning Protection of 500-kV DC Gas-Insulated Lines (GIL) With Integrated Surge Arresters , 2015, IEEE Transactions on Power Delivery.

[15]  Milan S. Savic,et al.  Substation Lightning Performance Estimation Due to Strikes Into Connected Overhead Lines , 2015, IEEE Transactions on Power Delivery.

[16]  Silverio Visacro,et al.  The Impact of the Frequency Dependence of Soil Parameters on the Lightning Performance of Transmission Lines , 2015, IEEE Transactions on Electromagnetic Compatibility.

[17]  Farhan Mahmood,et al.  Investigation of Lightning Electromagnetic Fields on Underground Cables in Wind Farms , 2016, IEEE Transactions on Electromagnetic Compatibility.

[18]  Behrooz Vahidi,et al.  LPM-Based Shielding Performance Analysis of High-Voltage Substations Against Direct Lightning Strokes , 2017, IEEE Transactions on Power Delivery.

[19]  Stefano Lauria,et al.  Tower Grounding Improvement Versus Line Surge Arresters: Comparison of Remedial Measures for High-BFOR Subtransmission Lines , 2015, IEEE Transactions on Industry Applications.

[20]  Ivo Uglešić,et al.  Lightning overvoltage protection of combined overhead line and underground cable distribution network , 2016 .

[21]  S Okabe,et al.  Experimental Investigation to Calculate the Lightning Outage Rate of a Distribution System , 2010, IEEE Transactions on Power Delivery.

[22]  G. V. Podporkin,et al.  Lightning protection of distribution lines by long flashover arresters (LFA) , 1998 .

[23]  Dong Wu,et al.  Development of an arc-extinguishing lightning protection gap for 35 kV overhead power lines , 2017 .

[24]  Jiming Chen,et al.  Calculation of Lightning Flashover Rates of Overhead Distribution Lines Considering Direct and Indirect Strokes , 2014, IEEE Transactions on Electromagnetic Compatibility.

[26]  Matti Lehtonen,et al.  Simulation of combined shield wire and MOV protection on distribution lines in severe lightning areas , 2007 .

[27]  Lambros Ekonomou,et al.  Effect of the grounding resistance to the behaviour of high-voltage transmission lines' surge arresters , 2014 .

[28]  L. V. Bewley,et al.  Traveling Waves on Transmission Systems , 1931, Transactions of the American Institute of Electrical Engineers.

[29]  J.A. Martinez,et al.  Parameter determination for modeling systems transients-Part V: Surge arresters , 2005, IEEE Transactions on Power Delivery.