Evaluation and calibration of an electromagnetic tracking device for biomechanical analysis of lifting tasks.

Electromagnetic motion tracking devices are increasingly used as a kinematic measuring tool. The aim of this study was to evaluate a long-range transmitter in an environment with a conventional force plate present in order to assess its suitability for further biomechanical applications. Using a calibration apparatus developed in our lab and Optotrack measurements, the performances of the Motion Star were evaluated. Positions and orientations were measured in a 140 x 80 x 120 cm(3) space centered on the force plate. Using a mathematical model developed at Queen's University, these data were calibrated. Errors on position and orientation were less than 150 mm and 10 degrees before calibration of the Motion Star, and less than 20mm and 2 degrees after calibration, with no differences between data collected with the force plate switched on/off. These errors did not depend on sensor orientation. Variability of the signal was small indicating minimal noise. Field distortion was the largest source of measurement error, which increased with the distance between the transmitter and the sensor and the proximity of the sensor to the force plate. Before its use for biomechanical analysis of lifting tasks and validation of dynamic models using force plate data, the data from electromagnetic motion tracking devices must be calibrated to decrease the errors due to electromagnetic field distortion.

[1]  A. Grishman Biomedical sciences instrumentation , 1964 .

[2]  James A. Johnson,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[3]  J Cholewicki,et al.  Methodological considerations for using inductive sensors (3SPACE ISOTRAK) to monitor 3-D orthopaedic joint motion. , 1997, Clinical biomechanics.

[4]  A M Bull,et al.  Accuracy of an electromagnetic tracking device. , 1997, Journal of biomechanics.

[5]  M J Pearcy,et al.  New method for the non-invasive three-dimensional measurement of human back movement. , 1989, Clinical biomechanics.

[6]  F. V. D. van der Helm,et al.  Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies. , 1999, Journal of biomechanics.

[7]  M J Pearcy,et al.  Kinematics and movement sequencing during flexion of the lumbar spine. , 1999, Clinical biomechanics.

[8]  A. Mannion,et al.  A comparison of two motion analysis devices used in the measurement of lumbar spinal mobility. , 1999, Clinical biomechanics.

[9]  J J Stone,et al.  The use of a direct current electromagnetic tracking device in a metallic environment. , 1996, Biomedical sciences instrumentation.

[10]  G A Dumas,et al.  Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis. , 1998, Journal of biomechanics.

[11]  M. Adams,et al.  A technique for quantifying the bending moment acting on the lumbar spine in vivo. , 1991, Journal of biomechanics.

[12]  G A Dumas,et al.  Calibration of position and angular data from a magnetic tracking device. , 2000, Journal of biomechanics.

[13]  K N An,et al.  Application of a magnetic tracking device to kinesiologic studies. , 1988, Journal of biomechanics.