Efficient single-shot Z-shim EPI via spatial and temporal encoding

Echo planar imaging (EPI) is used widely for neurological fMRI studies. However, in regions of magnetic field inhomogeneity—particularly near the nasal sinuses—EPI suffers from signal dropout. Z-shim methods are one approach to recover this lost signal, where a z gradient is employed prior to the EPI readout echo train to counter phase accumulation in the signal dropout region. Typically, two separate images of the same region are acquired under different z-shim gradient strengths, and then combined into a composite image. Single-shot z-shim methods give improved temporal resolution, but with a cost of longer echo trains, which increases geometric distortion. Here, we combine parallel MR imaging (pMRI) with a single-shot z-shim method to achieve short echo train lengths. We also employ temporal encoding to counter Nyquist ghost effects, which improves the pMRI calibration. We demonstrate the method with phantom images, and evaluate its suitability for fMRI applications.

[1]  J. Frahm,et al.  Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation , 1988, Magnetic resonance in medicine.

[2]  Yihong Yang,et al.  Single-Shot Interleaved Z-Shim EPI with Optimized Compensation for Signal Losses due to Susceptibility-Induced Field Inhomogeneity at 3 T , 2002, NeuroImage.

[3]  N J Pelc,et al.  Unaliasing by Fourier‐encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI , 1999, Magnetic resonance in medicine.

[4]  Huan Tan,et al.  Improved self-referenced parallel MRI imaging in EPI by using UNFOLD to remove Nyquist ghosts , 2009 .

[5]  F. Ye,et al.  Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE) , 2007, Magnetic resonance in medicine.

[6]  Dana H Brooks,et al.  Using GRAPPA to improve autocalibrated coil sensitivity estimation for the SENSE family of parallel imaging reconstruction algorithms , 2008, Magnetic resonance in medicine.

[7]  W Scott Hoge,et al.  Robust EPI Nyquist ghost elimination via spatial and temporal encoding , 2010, Magnetic resonance in medicine.

[8]  Xiaoping Hu,et al.  Simultaneous acquisition of gradient‐echo and asymmetric spin‐echo for single‐shot z‐shim: Z‐SAGA , 2004, Magnetic resonance in medicine.

[9]  R T Constable,et al.  Functional MR imaging using gradient‐echo echo‐planar imaging in the presence of large static field inhomogeneities , 1995, Journal of magnetic resonance imaging : JMRI.

[10]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[11]  A. Song,et al.  Single‐shot EPI with signal recovery from the susceptibility‐induced losses , 2001, Magnetic resonance in medicine.