The Amplatzer® Membranous VSD Occluder and the vulnerability of the atrioventricular conduction system

Abstract Transcatheter closure of ventricular septal defects with the Amplatzer® Membranous VSD Occluder has yielded promising initial results, but disturbances of conduction, including complete heart block, have been reported. We report our experience with the Amplatzer occluder in 35 patients with a median age 4.5 years, the defects being sized angiographically at 4.4 plus or minus 1.1 millimetres, with a range from 3 to 8 millimetres, and the size of the occluder varying from 4 to 12 millimetres. Over a median follow-up of 2.5 years, the rate of complete closure was 87% and 91%, at 1 and 2 years respectively, while 2 patients required surgical closure of the defect subsequent to the insertion of the device. Persistent regurgitation across the tricuspid valve related to the occluder was observed in 3 patients, and in 6 patients across the aortic valve. Abnormalities of conduction related to the procedure were noted in 7 patients, one-fifth of the cohort. The disturbances were transient in 1 patient, but permanent in 6, in one of the latter progressing after 6 months from left bundle branch block to intermittent Mobitz II second-degree atrioventricular block in association with expansion of the occluder. We conclude that transcatheter closure of perimembranous ventricular septal defects with the Amplatzer occluder is effective with limited complications, but the incidence of immediate and progressive disturbances of conduction related to the proximity of conduction tissues to the rims of the occluder stress the importance of larger and longer studies to assess the safety of this procedure.

[1]  A. Becker,et al.  The Anatomy of Ventricular Septal Defects and Their Conduction Tissues , 2006 .

[2]  Q. Cao,et al.  Transcatheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: results of the U.S. phase I trial. , 2006, Journal of the American College of Cardiology.

[3]  D. Negura,et al.  Transcatheter closure of congenital ventricular septal defect with Amplatzer septal occluders. , 2005, The American journal of cardiology.

[4]  W. Yip,et al.  Heart block and empirical therapy after transcatheter closure of perimembranous ventricular septal defect , 2005, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[5]  K. Sun,et al.  Percutaneous Closure of Perimembranous Ventricular Septal Defects with the Eccentric Amplatzer Device: Multicenter Follow-up Study , 2005, Pediatric Cardiology.

[6]  K. Gauvreau,et al.  Transcatheter Device Closure of Congenital and Postoperative Residual Ventricular Septal Defects , 2004, Circulation.

[7]  Q. Cao,et al.  Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder: immediate and mid-term results of a U.S. registry. , 2004, Journal of the American College of Cardiology.

[8]  P. Ewert,et al.  Initial human experience with the Amplatzer perimembranous ventricular septal occluder device , 2003, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[9]  T. Fukuda,et al.  Shallow stitching close to the rim of the ventricular septal defect eliminates injury to the right bundle branch. , 2002, The Annals of thoracic surgery.

[10]  M. Chessa,et al.  Transcatheter coil closure of muscular ventricular septal defects. , 2001, Journal of interventional cardiology.

[11]  V. Bonatti,et al.  Early and late postoperative complete heart block in pediatric patients submitted to open-heart surgery for congenital heart disease. , 1998, La Pediatria medica e chirurgica : Medical and surgical pediatrics.

[12]  E. Sideris,et al.  Occlusion of congenital ventricular septal defects by the buttoned device. "Buttoned device" Clinical Trials International Register. , 1997, Heart.

[13]  J. F. Keane,et al.  Preoperative transcatheter closure of congenital muscular ventricular septal defects. , 1991, The New England journal of medicine.

[14]  A. Davignon,et al.  Ventricular arrhythmias after correction of ventricular septal defects: importance of surgical approach. , 1990, Journal of the American College of Cardiology.

[15]  J. F. Keane,et al.  Transcatheter closure of ventricular septal defects. , 1988, Circulation.

[16]  G. Trusler,et al.  Conduction disturbances after surgical correction of ventricular septal defect by the atrial approach. , 1979, British heart journal.

[17]  S. Pedra,et al.  PEDIATRIC AND CONGENITAL HEART DISEASE Original Studies Percutaneous Closure of Perimembranous Ventricular Septal Defects With the Amplatzer Device: Technical and Morphological Considerations , 2004 .

[18]  H. Oku,et al.  Onset of Complete Atrioventricular Block 15 Years After Ventricular Septal Defect Surgery , 2001, Pediatric Cardiology.

[19]  M. Leval,et al.  Surgery for Congenital Heart Defects , 1994 .